MTC-500
Option F
Option C
STANDARD MAX SERIES
Option V
Featuring:
• Over 3.5 watts/in3 power density
• 80% overall efficiency
• VMEbus and Multibus II system
compatibility
• Meets international safety agency
requirements
• All outputs regulated ±1%
• High peak currents for motor
starting
• System air or self-cooling options
• AC automatic line selection option
MODEL
PWR
MAX-403-0512
MAX-503-0512
MAX-504-1205
MAX-504-1212
MAX-504-1224
MAX-504-1252
400
500
500
500
500
500
OUTPUT #1
+5V
+5V
+5V
+5V
+5V
+5V
@
@
@
@
@
@
70A
80A
80A
80A
80A
80A
OUTPUT #2
+12V
+12V
+12V
+12V
+12V
+12V
@
@
@
@
@
@
10/16A pk
10/16A pk
10/16A pk
10/16A pk
10/16A pk
10/16A pk
OUTPUT #3
OUTPUT #4
-12V @ 6A
-12V @ 10A
-12V @ 10A
-12V @ 10A
-12V @ 10A
-5.2V @ 10A
5.2V @ 2A
12V @ 2A
+24V @ 2A
12V @ 2A
TELECOM MTC SERIES
MODEL
PWR
OUTPUT #1
OUTPUT #2
OUTPUT #3
MTC-503-0512
MTC-503-0515
500
500
+5V @ 70A
+5V @ 70A
+12V @ 10A
+15V @ 8A
-12V @ 10A
-15V @ 8A
VMEbus and Multibus compatibility is
only one feature of this series. You’ll find
switchers to power up to 80 Amps of
logic and four hard disk drives — with
up to 16 Amps peak current to meet
peripheral startup needs.
You’ll find the outputs you need for
ISDN, LAN, T1 applications and for
standard voice and data networks.
High-current auxiliary outputs provide
regulation characteristics for proper
operation of line drivers, network interfaces, and RS232-type outputs. And,
you can upgrade power output by 25%
without redesigning for a larger power
supply.
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com
400, 500 WATTS
11.5” x 5”x 2.5”
MAX-400, 500 MTC-500
Dimensions:
MAX, MTC-500
MAX, MTC-500 with Option F
4.5 lbs - 2.0 kgs
5.2 lbs - 2.4 kgs
Inches
Millimeters
SPECIFICATIONS: ALL MODELS
INPUT
AC Input: 90-132 Vac/180-264 Vac, 47 to 63 Hz. User selectable. See option “A” for automatic
line selection. Internally fused for 12 A.
Inrush: Cold start AC current is less than 80 A at 115 Vac and 20 A at 230 Vac. Limited by
thermistor.
Holdup Time: 16 ms minimum after removal of power, at nominal line, full load.
Efficiency: 80% typical.
Brownout Protection: Holds regulation to 85 Vac or 170 Vac.
OUTPUT
Adjustability: User adjustable ±5% minimum.
Line & Load Reg: ±1% over AC input range and 0 to 100% load change. Output #1 requires
minimum load of 10%.
Ripple & Noise: Less than 1% p-p or 100 mV, whichever is greater.
Remote Sense (Output #1): Compensates for 250 mV total line drop. Open sense lead
protection.
Temperature Coefficient: 0.02% per degree C.
Stability: 0.1% over 8 hours after 30 minutes warm-up.
Transient Response (Output #1): Output voltage returns to within 1% in less than 500 µs for
a 50% load change. Peak transient does not exceed 5%.
Overload Protection: All outputs are protected against overload and short circuit. Automatic
recovery upon removal of fault.
Overvoltage Protection (Output #1): Protects load against power supply induced overvoltage.
Trip point is factory set so that output voltage cannot exceed 136% of nominal.
Remote Inhibit: Contact closure to the negative sense line drops output power to nominal
zero.
Reverse Voltage: Protected against reverse voltage up to supply current rating.
Option “G”, DC Power Good: Provides a TTL “1” open collector when output #1 is above 4.6
V nominal. Not available if option “P” is selected.
Option “P”, AC Power Fail: Provides TTL “0” 5 ms before output voltage goes out of
regulation band upon loss of AC power. VMEbus compatible, provides 48 mA sink current
capability. Not available if option “G” is selected.
Option “V”, Fan/Cover Assembly: Low profile, end venting cover with integral ball-bearing
fan.
Consult factory for other available options.
AC INPUT
FUNCTION
Input Select
TB1- (L )
TB1- (N)
TB1- ( )
115 VAC
Short
Line
Neutral
Safety Ground
230 VAC
Open
Line 1
Line 2
Safety Ground
LOCATION
Terminal marked +V
Terminal marked COM
TB2-3
TB2-4
TB2-5
TB2-4
TB2-1
TB2-2
NOTES
Main Output
Rtn (Common)
Barrier strip
#6-32 screws
3/8 centers.
DC OUTPUT
FUNCTION
Output #1
Output #2
Output #3
ENVIRONMENTAL
Thermal Protection: Shuts down power supply if overheated. Automatic recovery.
Temperature Range: 0° to 50°C at full ratings. Derate to half power at 70°C.
Safety Agencies: Most models are approved to UL1950; CSA 22.2 #234; IEC 950 and TÜV
EN60950, Class 1 SELV., CE 72/23/EEC/93/68EEC (low voltage directive).
Conducted RFI: Meets FCC Part 15, Subpart J, Class A; EN55022 Class B; CISPR 22 Class B.
Cooling: 30 CFM required to achieve full ratings.
Output Isolation: Isolated from ground 50 Vdc.
STATUS AND CONTROL
OPTIONS:
FUNCTION
Remote Sense
Option “A”, AC Auto-Range: Automatically selects proper AC line voltage range to enable
power operation at either 115 or 230 Vac without user intervention.
Option “C”, Cover: Limits contact with power supply interior.
Option “F”, Fan/Cover Assembly: Cover with integral ball-bearing fan provides proper cooling
to achieve full ratings at 50°C ambient temperature.
CONNECTORS
0.250 Male Fastons
Output #4*
(If provided)
CONNECTOR
Bus bars
#1/4-20 screws
Rtn (Common)
Rtn (Common)
(+)
(–)
Barrier Strip
#6-32 screws
3.8” centers
*Rtn connected to common only if output is polarized in product selection chart
AC Power Fail or
DC Power Good*
Inhibit
LOCATION
J1-1 (+S)
J1-2 (-S)
J1-3 (PF)
NOTES
Output #1 Sense
Output #1 Sense Rtn
Reference to J1-2
J1-4(1H)
Short to J1-2
CONNECTOR
AMP MTA type
#640456-4 pin
header (locking)
*Optional function
Condor D.C. Power Supplies, Inc., A subsidiary of SL Industries, Inc. 805-486-4565 • (800) 235-5929 Fax: (805) 487-8911 http://www.condorpower.com