NIC NFVC6125F5R00TRF Surface mount fuse Datasheet

Surface Mount Fuse
NFVC-F Series
FEATURES
RoHS
Compliant
• FAST ACTING, HIGH INRUSH WITHSTANDING
includes all homogeneous materials*
• CASE SIZE 6125 (6.1MM X 2.5MM); 2410 (0.24" x 0.10")
• 65VAC & 125VAC WITH CURRENT RATINGS UP TO 20 AMPS
*See
e Part Number System for Details
• SAFETY STANDARD APPROVAL (UL File Number E358637)
• COMPATIBLE WITH FLOW AND REFLOW SOLDERING
• RoHS COMPLIANT & HALOGEN FREE
SPECIFICATIONS
Type
Case Size
Rated Current Rated Voltage
(Amps)
(VAC)
NFVC
6125
1.0 ~ 20*
65V & 125V
*For current ratings below 1A contact NIC
Temperature
Range
Case Dimensions
L
-55°C ~ +125°C 6.1 ± 0.20
W
H
P
2.5 ± 0.1
2.5 ± 0.1
1.4 ± 0.1
L
NFV
1.25A
Fuse element
(Silver Plate or Copper Alloy Wire)
W
(Top View)
P
Au Plated
Brass End Cap
P
Ceramic
Body
H
(Side View)
PART NUMBERING SYSTEM
NFVC 6125 F 1R25 TR F
RoHS Compliant*
TR = Tape & Reel
Current Rating: 8R00 = 8Amps
F = Fast Acting
Case Size Code
Series
*Exemption 7a - Lead in high melting temperature solder (lead
based alloy with 85% by weight or more lead)
SAFETY AGENCY CERTIFICATION
Agency
File Number
Ampere Range
UL
1.0 ~ 20
E358637
UL Certification: JDYX2.E358637
UL Certification Canada: JDYX8.E358637
Fuses, Supplemental Certified Components
These fuses provide supplemental protection in end-use equipment to provide protection for components or internal circuits. They are not suitable
for branch or feeder circuit use
NIC COMPONENTS CORP. www.niccomp.com
www.lowESR.com
www.RFpassives.com
SPECIFICATIONS ARE SUBJECT TO CHANGE
www.SMTmagnetics.com
1
Surface Mount Fuse
NFVC-F Series
AVAILABLE VALUES AND RATINGS
Part Number
Current Rating
@ +25°C
Marking
NFVC6125F1R00TRF
NFVC6125F1R25TRF
NFVC6125F1R60TRF
NFVC6125F2R00TRF
NFVC6125F2R50TRF
NFVC6125F3R15TRF
NFVC6125F4R00TRF
NFVC6125F5R00TRF
NFVC6125F6R30TRF
NFVC6125F7R00TRF
NFVC6125F8R00TRF
NFVC6125F10R0TRF
NFVC6125F12R0TRF
NFVC6125F15R0TRF
NFVC6125F20R0TRF
1.0
1.25
1.6
2.0
2.5
3.15
4.0
5.0
6.3
7.0
8.0
10
12
15
20
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
6.3A
7A
8A
10A
12A
15A
20A
Opening Time
Typical Cold
Resistance (% of Current Rating)
(mΩ)*
100%
200%
80
60
38
30
27
21
16
14
10
9.4
7.4
5.9
4.8
3.7
3.0
4 hrs
min.
5 sec.
max.
4 hrs
min.
20 sec.
max.
Melting I2T
(A2×s)
nominal**
0.56
0.84
1.23
1.34
1.43
2.05
3.44
4.84
10.55
10.58
17.62
30.30
42.22
69.75
132.04
Rated
Voltage
Interrupt Rating
125VAC
UL: 50A, 125VAC, 160VDC
65VAC
UL: 50A, 65VAC, 65VDC
* Resistance measured at < 10% rated current and +25°C
** Melting I2T at 10 times the rated current.
TEMPERATURE DERATING CURVE
Percentage of Current Rating
120
Temp (°C)
-55
-40
-25
-10
0
+10
+25
+35
+45
+55
+65
+75
+85
+95
+105
+115
+125
100
80
60
40
20
0
-50
-35
-20
-5
10
25
40
55
70
85
100
115
130
Ambient Temperature (°C)
300°C
260°C
220°C
200°C
REFLOW SOLDERING TEMPERATURE PROFILE
Peak Temperature 260°C
5 sec. max.
Ramp-up 3°C/sec. max.
Ramp-down 6°C/sec. max.
Derating Factor
1.080
1.065
1.050
1.035
1.025
1.015
1.00
0.990
0.980
0.970
0.960
0.950
0.940
0.930
0.920
0.910
0.900
Recommended Reflow Land Pattern Dimensions (mm)
Case Size
A
B
C
D
6125
3.0 ± 0.3
8.0 ± 0.3
3.0 ± 0.3
2.5 ± 0.3
C
150°C
100°C
Pre-heat 150 ~ 200°C
60 ~ 120 sec.
Time above liquidus
20 ~ 40 sec. max.
D
50°C
D
B
0
2
A
NIC COMPONENTS CORP. www.niccomp.com
www.lowESR.com
www.RFpassives.com
SPECIFICATIONS ARE SUBJECT TO CHANGE
www.SMTmagnetics.com
Surface Mount Fuse
NFVC-F Series
RELIABILITY TEST
Item
Test Conditions/Method
Performance
Standard
100% In
UL248-14
Interrupting Ability
1A ~ 10A Parts: 50A@125VAC/160VDC
12A ~ 20A Parts: 50A@65VAC & VDC
No fusing; 4 hours minimum
1 ~ 10A <5 seconds
12 ~ 20A < 20 seconds
1mS ~ 10mS
1 ~ 6.3A <300mV
7 ~ 10A <220mV
12 ~ 20A < 150mV
|ΔR| < 10%
1 ~ 6.3A ΔT < 75°C
7 ~ 10A ΔT < 95°C
|ΔR| < 10%
12 ~ 20A ΔT <105°C
Without permanent arcing, ignition
and bursting of fuse link
Solderability
240°C ±5°C, 3 seconds ±0.5s
95% coverage minimum
Resistance to Soldering Heat
260°C ±5°C, 10 seconds ±0.5s
|ΔR|: <10%
High Temperature Operating Life
T = 70°C ±2°C, 0.6 In, 96 hours
|ΔR|: <10%
Humidity (Steady State)
T = 40°C ±2°C, 90 ~ 95% RH, 1000 hours
|ΔR|: <10%
Low Temperature Storage
High Temperature Storage
T = -55°C ±3°C, 96 hours
T = 125°C ±2°C, 96 hours
|ΔR|: <10%
|ΔR|: <10%
Salt Spray
5% salt solution, 48 hours
|ΔR|: <10%
Thermal Shock
5 cycles between -55°C/+125°C,
60 minutes; each extreme
|ΔR|: <10%
Time/Current
200% In
1000% In
Voltage Drop
100% of rated current
Endurance Test
100 cycles at 100% of rated current for 1
hour, off for 15 minutes followed by
125% of rated current for 1 hour
100% of rated current for 4 hours
Refer to ???? File
IEC-60127-4
IEC-60127-4
IEC-60127-4
UL248-14
UL248-14
IEC-60127-4
IEC-60127-4
IEC-60068-2-20
Mil-Std-202
Mil-Std-202
Method 210
Mil-Std-202
Method 108
Mil-Std-202
Method 103
IEC-60068-2-1
IEC-60068-2-2
Mil-Std-202
Method 101
IEC 60068-2-14
EMBOSSED PLASTIC CARRIER DIMENSIONS (mm)
Type
A
B
W
F
E
P1
P2
φD
T1
Ko
NFVC6125F
2.70 ±0.10
6.40 ±0.10
12.0 ±0.15
5.50 ±0.10
1.75 ±0.10
4.00 ±0.10
2.00 ±0.10
1.50 min.
0.25 ±0.05
2.70 ±0.10
4.0 ±0.1
P2
1.5 +0.1
-0
1.75 ±0.1
t
F
W
B
Do
A
P1
Ko
NIC COMPONENTS CORP. www.niccomp.com
www.lowESR.com
www.RFpassives.com
SPECIFICATIONS ARE SUBJECT TO CHANGE
www.SMTmagnetics.com
3
Surface Mount Fuse
NFVC-S Series
REEL DIMENSIONS (mm) AND QUANTITY
Type
A ±2.0
B ±2.0
C ±0.5
E ±0.20
W ±1.0
Qty
NFVC6125F
178
58
13
2.0
12.5
1,000
E
C
B
D
W
A
4
NIC COMPONENTS CORP. www.niccomp.com
www.lowESR.com
www.RFpassives.com
SPECIFICATIONS ARE SUBJECT TO CHANGE
www.SMTmagnetics.com