MACOM HC-4/115VDC Make & break load switching Datasheet

8 kV
Kilovac HC-2
HC-4
Features:
No Load Switching
HC-2
• Vacuum dielectric and copper contacts for
high current carry rating of 25 Amps
• Not designed for power switching
• Stable, low contact resistance
• Meets requirements of MIL-R-83725
Make & Break Load Switching
HC-4
• Tungsten contacts for long life in power
switching applications
• Vacuum dielectric for arc suppression when
making or breaking a load
• Widely used in defibillator applications
• Meets requirements of MIL-R-83725
Kilovac HC-6
Features:
Make Only
• Tungsten contacts for switching high in-rush
loads
• SF-6 gas-filled for capacitive discharge
applications
• Ideal for ESD testing applications
Part Number
PRODUCT SPECIFICATIONS
Units
HC-2
COIL DATA
HC-4
HC-6
Nominal, Volts dc
12
26.5
Pickup, Volts dc, Maximum
8
16
80
.5 - 5
1 - 10
5 - 50
80
335
6000
Contact Arrangement ..........................................................
SPDT
SPDT
SPDT
Contact Form ........................................................................
C
C
C
Drop-Out, Volts dc
10
10
10
Coil Resistance (Ohms ±10%)
Test Voltage (dc or 60Hz) ...................................................
kV Peak
Rated Operating Voltage
Ratings listed are for 25°C, sea level conditions
dc or 60 Hz .....................................................................
8
8
8
2.5 MHz ...........................................................................
-
-
-
16 MHz ............................................................................
-
-
-
32 MHz ............................................................................
-
-
-
dc or 60 Hz .....................................................................
25
15
8
2.5 MHz ...........................................................................
-
-
-
16 MHz ............................................................................
-
-
-
32 MHz ............................................................................
-
-
-
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
500
500
500
Between Open Contacts .................................................
-
-
-
Open Contacts to Ground ..............................................
-
-
-
Continuous Carry Current , Maximum
Contact Capacitance
115
A RMS
PART NUMBER SELECTION
Sample Part No.
HC Model
2
4
6
Coil Voltage
Blank = 26.5 Vdc
/12Vdc = 12 Vdc
/115Vdc = 115 Vdc
6
/12Vdc
pF
Contact Resistance, Maximum ...........................................
ohms
0.01
0.02
0.5*
Operate Time, Maximum .....................................................
ms
6
6
6
Release Time, Maximum .....................................................
ms
6
6
6
Shock, 11 ms 1/2 Sine ........................................................
Peak G's
50
50
50
Vibration, 10 G’s Peak .........................................................
Hz
55-2000
55-2000
55-2000
Operating Ambient Temperature Range ............................
o
C
-55 to +125
-55 to +125
-55 to +125
Mechanical Life (Operations x 106) ....................................
Cycles
2
2
1
Weight, Nominal ..................................................................
oz.
1.4
1.4
1.4
* Contact resistance for gas-filled relays is measured at 28 Vdc, 1 amp
CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail [email protected] / website www.ciitech.com
36