ETC2 EI3015NPOSL-1 Proximity sensors inductive stainless steel housing Datasheet

Proximity Sensors Inductive
Stainless Steel Housing
Types EI, DC, M12, M18, M30
• Stainless steel housing, cylindrical
• Diameter: M12, M18, M30
• Short or long versions
• Sensing distance: 2 to 15 mm
• Power supply: 10 to 40 VDC
• Output: Transistor NPN/PNP, make or break switching
• Protection: Short-circuit and reverse polarity
• LED-indication for output ON
• 2 m cable or plug M12
Product Description
Ordering Key
Proximity switch in housings
ranging from M12 to M30.
Short or long versions in stan-
Type
Housing diameter (mm)
Rated operating dist. (mm)
Output type
Housing material
Body style
Plug
dard stainless steel housing.
Made after Euronorm EN 50
008.
EI 1202 NPOSS-1
Type Selection DC Types, Cable and M12 Plug
Housing Body
diameter style
Connection
Rated
operating
dist. (Sn)
Ordering no.
Transistor NPN
Make switching
Ordering no.
Transistor NPN
Break switching
Ordering no.
Transistor PNP
Make switching
Ordering no.
Transistor PNP
Break switching
M12
M12
M12
M12
M12
M12
M12
M12
Short
Short
Long
Long
Short
Short
Long
Long
Cable
Plug
Cable
Plug
Cable
Plug
Cable
Plug
2 mm 1)
2 mm 1)
2 mm 1)
2 mm 1)
4 mm 2)
4 mm 2)
4 mm 2)
4 mm 2)
EI 1202 NPOSS
EI 1202 NPOSS-1
EI 1202 NPOSL
EI 1202 NPOSL-1
EI 1204 NPOSS
EI 1204 NPOSS-1
EI 1204 NPOSL
EI 1204 NPOSL-1
EI 1202 NPCSS
EI 1202 NPCSS-1
EI 1202 NPCSL
EI 1202 NPCSL-1
EI 1204 NPCSS
EI 1204 NPCSS-1
EI 1204 NPCSL
EI 1204 NPCSL-1
EI 1202 PPOSS
EI 1202 PPOSS-1
EI 1202 PPOSL
EI 1202 PPOSL-1
EI 1204 PPOSS
EI 1204 PPOSS-1
EI 1204 PPOSL
EI 1204 PPOSL-1
EI 1202 PPCSS
EI 1202 PPCSS-1
EI 1202 PPCSL
EI 1202 PPCSL-1
EI 1204 PPCSS
EI 1204 PPCSS-1
EI 1204 PPCSL
EI 1204 PPCSL-1
M18
M18
M18
M18
M18
M18
M18
M18
Short
Short
Long
Long
Short
Short
Long
Long
Cable
Plug
Cable
Plug
Cable
Plug
Cable
Plug
5 mm 1)
5 mm 1)
5 mm 1)
5 mm 1)
8 mm 2)
8 mm 2)
8 mm 2)
8 mm 2)
EI 1805 NPOSS
EI 1805 NPOSS-1
EI 1805 NPOSL
EI 1805 NPOSL-1
EI 1808 NPOSS
EI 1808 NPOSS-1
EI 1808 NPOSL
EI 1808 NPOSL-1
EI 1805 NPCSS
EI 1805 NPCSS-1
EI 1805 NPCSL
EI 1805 NPCSL-1
EI 1808 NPCSS
EI 1808 NPCSS-1
EI 1808 NPCSL
EI 1808 NPCSL-1
EI 1805 PPOSS
EI 1805 PPOSS-1
EI 1805 PPOSL
EI 1805 PPOSL-1
EI 1808 PPOSS
EI 1808 PPOSS-1
EI 1808 PPOSL
EI 1808 PPOSL-1
EI 1805 PPCSS
EI 1805 PPCSS-1
EI 1805 PPCSL
EI 1805 PPCSL-1
EI 1808 PPCSS
EI 1808 PPCSS-1
EI 1808 PPCSL
EI 1808 PPCSL-1
M30
M30
M30
M30
M30
M30
M30
M30
Short
Short
Long
Long
Short
Short
Long
Long
Cable
Plug
Cable
Plug
Cable
Plug
Cable
Plug
10 mm 1)
10 mm 1)
10 mm 1)
10 mm 1)
15 mm 2)
15 mm 2)
15 mm 2)
15 mm 2)
EI 3010 NPOSS
EI 3010 NPOSS-1
EI 3010 NPOSL
EI 3010 NPOSL-1
EI 3015 NPOSS
EI 3015 NPOSS-1
EI 3015 NPOSL
EI 3015 NPOSL-1
EI 3010 NPCSS
EI 3010 NPCSS-1
EI 3010 NPCSL
EI 3010 NPCSL-1
EI 3015 NPCSS
EI 3015 NPCSS-1
EI 3015 NPCSL
EI 3015 NPCSL-1
EI 3010 PPOSS
EI 3010 PPOSS-1
EI 3010 PPOSL
EI 3010 PPOSL-1
EI 3015 PPOSS
EI 3015 PPOSS-1
EI 3015 PPOSL
EI 3015 PPOSL-1
EI 3010 PPCSS
EI 3010 PPCSS-1
EI 3010 PPCSL
EI 3010 PPCSL-1
EI 3015 PPCSS
EI 3015 PPCSS-1
EI 3015 PPCSL
EI 3015 PPCSL-1
1)
2)
For flush mounting in metal
For non-flush mounting in metal
Make switching = Normally Open (NO)
Break switching = Normally Closed (NC)
Specifications are subject to change without notice (20.08.01)
1
EI, DC, M12, M18, M30
Specifications
Rated operational volt. (Ue)
(UB)
Effective operating dist. (Sr)
Usable operating dist. (S)
Ambient temperature
Operating
Storage
Degree of protection
Housing material
Body
Front
Back
Connection
Cable
12 to 36 VDC
10 to 40 VDC
(ripple included)
≤ 10%
Ripple
Rated operational current (Ie)
Continuous
≤ 200 mA
Output ON: < 6.5 mA
No-load supply current (Io)
Output OFF: < 2.7 mA
Voltage drop (Ud)
≤ 2 VDC at max. load
Protection
Reverse polarity,
short-circuit, transients
Transient voltage
≤ 700 V/0.5 J
EMC
Approved according to
EN 50 080, EN 50 081
Power ON delay
< 10 ms
Frequency of operating
EI 1202 800 Hz
cycles (f)
EI 1204 500 Hz
EI 1805 500 Hz
EI 1808 400 Hz
EI 3010 300 Hz
EI 3015 100 Hz
Indication for output ON
LED, yellow
Assured operating dist. (Sa)
0 ≤ Sa ≤ 0.81 Sn
Repeat accuracy (R)
≤ 5%
Hysteresis (H) (Differential travel) 1 to 15% of sensing distance
Plug
Cables for plug (-1)
Weight (cable excluded)
Tightening torque
Approvals
CE-marking
0.9 x Sn ≤ Sr ≤ 1.1 x Sn
0.9 x Sr ≤ Su ≤ 1.1 x Sr
-25° to +70°C (-13° to +158°F)
-30° to +80°C (-22° to +176°F)
IP 67 (Nema 1, 3, 4, 6, 13)
Stainless steel (1.4301)
Grey thermoplastic polyester
Black polyester
2 m, 3 x 0.3 mm2,
grey PVC,oil proof
M12 x 1
CONH1A serie
EI 12
10 g
EI 1805 18 g
EI 1808 20 g
EI 3010 50 g
EI 3015 70 g
EI 12
7.5 Nm (x)
17.5 Nm (y)
EI 18 27.5 Nm
EI 30 100.0 Nm
UL, CSA
Yes
Dimensions
Type
A
B
C
Ø mm mm
D
mm
E
mm
F
G
H
I
SW
K
L
mm mm mm mm mm Ø mm Ø mm
EI 1202 XPXSS
EI 1202 XPXSL
EI 1202 XPXSS-1
EI 1202 XPXSL-1
EI 1204 XPXSS
EI 1204 XPXSL
EI 1204 XPXSS-1
EI 1204 XPXSL-1
M12 x 1 x 30
M12 x 1 x 50
M12 x 1 x 30
M12 x 1 x 50
M12 x 1 x 30
M12 x 1 x 50
M12 x 1 x 30
M12 x 1 x 50
10.7
10.7
10.7
10.7
10.7
10.7
10.7
10.7
30
50
30
50
34
54
34
54
11
11
12.6
12.6
11
11
12.6
12.6
5.0
5.0
11.9
11.9
5.0
5.0
11.9
11.9
4
4
4
4
4
4
4
4
17
17
17
17
17
17
17
17
EI 1805 XPXSS
EI 1805 XPXSL
EI 1805 XPXSS-1
EI 1805 XPXSL-1
EI 1808 XPXSS
EI 1808 XPXSL
EI 1808 XPXSS-1
EI 1808 XPXSL-1
M18 x 1 x 30
M18 x 1 x 50
M18 x 1 x 30
M18 x 1 x 50
M18 x 1 x 30
M18 x 1 x 50
M18 x 1 x 30
M18 x 1 x 50
16.7
16.7
16.7
16.7
16.7
16.7
16.7
16.7
30
50
30
50
38
58
38
58
11.6
11.6
13.1
13.1
11.6
11.6
13.1
13.1
15.4
15.4
11.9
11.9
15.4
15.4
11.9
11.9
4
4
4
4
4
4
4
4
24
24
24
24
24
24
24
24
EI 3010 XPXSS
EI 3010 XPXSL
EI 3010 XPXSS-1
EI 3010 XPXSL-1
EI 3015 XPXSS
EI 3015 XPXSL
EI 3015 XPXSS-1
EI 3015 XPXSL-1
M30 x 1.5 x 30
M30 x 1.5 x 50
M30 x 1.5 x 30
M30 x 1.5 x 50
M30 x 1.5 x 30
M30 x 1.5 x 50
M30 x 1.5 x 30
M30 x 1.5 x 50
28
28
28
28
28
28
28
28
30
50
30
50
42
62
42
62
13.6
13.6
13.6
13.6
13.6
13.6
13.6
13.6
15.4
15.4
11.9
11.9
15.4
15.4
11.9
11.9
5
5
5
5
5
5
5
5
36
36
36
36
36
36
36
36
2
Specifications are subject to change without notice (20.08.01)
EI, DC, M12, M18, M30
Dimensions (cont.)
D
E
D
C
E
B
B
C
M 12 x 1
F
F
SW
A
SW
LED
Cable
A
LED
Plug
Wiring Diagrams
1 BN
+
1 BN
+
1 BN
+
1 BN
+
4 BK
2 WH
2 WH
4 BK
3 BU
3 BU
-
NPN - Make switching
-
NPN - Break switching
3 BU
3 BU
PNP - Make switching
PNP - Break switching
Installation Hints
To avoid interference from inductive voltage/
current peaks, separate the prox. switch power cables from any other power cables, e.g.
motor, contactor or solenoid cables
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
Incorrect
Correct
The cable should not be pulled
Power Supplies
Power supplies VDC:
> SS 130/140.
Power supplies with amplifier relays: > SV 190.
Specifications are subject to change without notice (20.08.01)
3
Similar pages