Honeywell NSCDFFN030PAUNV Trustabilityâ® board mount pressure sensors: nsc seriesâ uncompensated/unamplified Datasheet

TruStability® Board Mount
Pressure Sensors:
NSC Series–
Uncompensated/Unamplified
DESCRIPTION
The TruStability NSC Series-Uncompensated/Unamplified is
a piezoresistive silicon pressure sensor offering a ratiometric
analog output for reading pressure over the specified full scale
pressure span and temperature range.
Additionally, the NSC Series offers numerous package styles
and mounting options, making it easier for the device
manufacturer to integrate the product into their application.
The NSC Series is both unamplified and uncompensated. It
offers infinite resolution on the pressure signal. Frequency
response is limited only by the end user’s system. The sensor
will operate as specified from -40 C to 85 C [-40 F to
185 F].
These sensors measure absolute, differential, and gage
pressures. The absolute versions have an internal vacuum
reference and an output value proportional to absolute
pressure. Differential versions allow application of pressure to
either side of the sensing diaphragm. Gage versions are
referenced to atmospheric pressure and provide an output
proportional to pressure variations from atmosphere.
These products are ideal for those customers who want to do
their own compensation, calibration, and amplification in order
to make use of the maximum resolution of the bare sensor
output, leveraging a custom algorithm required for the
application.
The NSC Series sensors are intended for use with noncorrosive, non-ionic gases, such as air and other dry gases
and for non-corrosive, non-ionic liquids. All products are
designed and manufactured according to ISO 9001.
The NSC Series allows customers the flexibility of selfcalibration while still benefiting from the industry-leading
stability, accuracy, and repeatability that the Honeywell
TruStability® Pressure Sensors provide.
FEATURES AND BENEFITS (=competitive differentiator)
 Industry-leading long-term stability: Even after long-term
use and thermal extremes, these sensors perform
substantially better relative to stability than any other
pressure sensor available in the industry today:
Minimizes system calibration needs and maximizes
system performance
Helps support system uptime by eliminating the need to
service or replace the sensor during its application life
 Industry-leading accuracy: Extremely tight accuracy of
±0.25 %FSS BFSL:
Reduces software needed to correct system
inaccuracies, minimizing system design time
Supports system accuracy and warranty requirements
Helps to optimize system uptime
FEATURES AND BENEFITS (=competitive differentiator) (continued)
Extremely low power consumption (operating supply voltage
as low as 1.8 Vdc):
Modular, flexible design with numerous package
styles, pressure ports, and options simplify
Reduces power consumption
integration into the device manufacturer’s application
Provides extended battery life
Promotes energy efficiency
Single side wet media option allows the end
customer to use one port of the sensor with
Low operating voltage
condensing humidity or directly with non-corrosive
Sensitive: Meets specified pressure level requirements,
liquid media
providing enhanced sensitivity and accuracy over the range
 Small size: Miniature 10 mm x 10 mm [0.39 in x
Virtually insensitive to mounting orientation, allowing for
0.39 in] package is very small when compared to most
flexibility of use within the application
board mount pressure sensors
Ratiometric analog output
Occupies less area on the PCB
Infinite resolution
Typically allows for easy placement on crowded
Fast response time
PCBs or in small devices
RoHS compliant
 Repeatability: Provides excellent repeatability, high
Absolute, differential and gage types
accuracy and reliability under many demanding
Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar)
conditions
Also available in the HSC Series and the SSC Series which
are fully compensated and calibrated with amplified analog or
2
digital I C or SPI outputs
 Industry-leading flexibility:
POTENTIAL APPLICATIONS (=focus applications)
Medical:
Industrial:
Respiratory breathing circuits:
Nebulizers
Spirometers
Patient monitoring
Pneumatic components:
 Valves
 Pumps
 Actuators
Flow/pressure control:
Therapeutic hospital beds
Pneumatic systems:
 HVAC transmitters
 Automated pneumatic assembly equipment
 Pneumatic operator control systems
Gas collection/delivery:
 Hospital gas supply
Oxygen concentrators
Gas collection/delivery:
 Industrial gas supply
Precise sampling/gas flow:
 Blood analysis
 Gas chromatography
 Analytical instrument sampling systems
Precise sampling/gas flow:
 Barometry
 Gas chromatography
 Analytical instrument sampling systems
1
Table 1. Absolute Maximum Ratings
Parameter
Supply voltage (Vsupply)
ESD susceptibility (human body model)
Storage temperature
Soldering time and temperature:
Lead solder temperature (SIP, DIP)
Peak reflow temperature (SMT)
2
www.honeywell.com/sensing
Min.
-12.0
3
-40 [-40]
Max.
12.0
85 [185]
4 s max. at 250 °C [482 °F]
15 s max. at 250 °C [482 °F]
Unit
Vdc
kV
C [ F]
Table 2. Operating Specifications
Parameter
2
Supply voltage (Vsupply)
Supply current (at 5.0 Vdc supply)
4
Specified temperature range
Startup time
5
Accuracy
Min.
1.8
Max.
12.0
2
85 [185]
5
0.25
-40 [-40]
Table 3. Environmental Specifications
Parameter
Humidity
Vibration
Shock
7
Life
Solder reflow
Table 4. Wetted Materials
Parameter
Covers
Substrate
Adhesives
Electronic components
Typ.
3
5.0
1.5
Unit
Vdc
mA
C [ F]
ms
6
%FSS BFSL
Characteristic
0% to 95% RH, non-condensing
MIL-STD-202F, Curve AK (20.7 g random)
MIL-STD-202F, Method 213B, Condition F
1 million pressure cycles minimum
J-STD-020-C
8
Port 1 (Pressure Port)
high temperature polyamide
alumina ceramic
epoxy, RTV
ceramic, silicon
Port 2 (Reference Port)
high temperature polyamide
alumina ceramic
epoxy, RTV
silicon, glass, gold, solder
Notes:
1. Absolute maximum ratings are the extreme limits the device will withstand without damage.
2. Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage.
3. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
4. The specified temperature range is the temperature range over which the sensor will produce an output proportional to pressure within the
specified performance limits.
5. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at
25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability.
6. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (P max.) and minimum (Pmin.) limits of
the pressure range. (See Figure 1 for ranges.)
7. Life may vary depending on specific application in which sensor is utilized.
8. Contact Honeywell Customer Service for detailed material information.
CAUTION
PRODUCT DAMAGE
Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids.
Ensure liquid media contains no particulates. All TruStability sensors are dead-ended devices. Particulates can
accumulate inside the sensor, causing damage or affecting sensor output.
Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to
enter and settle within the pressure sensor if it is in this position.
Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a
dead-ended sensor is difficult and has limited effectiveness for removing residue.
Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance
and may lead to sensor failure.
Failure to comply with these instructions may result in product damage.
Honeywell Sensing and Control
3
Figure 1. Nomenclature and Order Guide
NSC _ _ _ N _ _ _ _ _ U N V
Series
Supply Voltage
V = Constant
Package
D = DIP (Dual Inline Pin)
M = SMT (Surface Mount Technology)
S = SIP (Single Inline Pin)
Compensation
N = Uncompensated
Amplification
U = Unamplified
Pressure Port (* indicates not available)
DIP
SMT
NN = No ports
NN = No ports
SIP
NN = No ports
AA = Dual axial
barbed ports,
opposite sides
*
*
AN = Single
axial barbed
port
AN = Single
axial barbed
port
AN = Single
axial barbed
port
LN = Single
axial barbless
port
LN = Single
axial barbless
port
LN = Single
axial barbless
port
*
*
FF = Fastener
mount, dual axial
barbed ports,
opposite sides
*
*
FN = Fastener
mount, single axial
barbed port
*
*
GN = Ribbed
fastener mount,
single axial
barbed port
*
*
RN = Single
radial barbed
port
RN = Single
radial barbed
port
RR = Dual radial
barbed ports,
same side
RR = Dual radial
barbed ports,
same side
RR = Dual radial
barbed ports,
same side
DR = Dual radial
barbed ports,
opposite sides
DR =Dual radial
barbed ports,
opposite sides
DR = Dual radial
barbed ports,
opposite sides
*
HH = Fastener
mount, dual
radial barbed
ports, same side
*
*
HN = Fastener
mount, single
radial barbed
port
*
*
MN = Manifold
mount, outer
diameter seal
*
*
SN = Manifold
mount, inner
diameter seal
Note:
9. See Table 5 for an explanation of sensor pressure types.
4
www.honeywell.com/sensing
1 psi to 150 psi
Absolute
015PA = 0 psi to 15 psi
030PA = 0 psi to 30 psi
060PA = 0 psi to 60 psi
100PA = 0 psi to 100 psi
150PA = 0 psi to 150 psi
Differential
001PD = ±1 psi
005PD = ±5 psi
015PD = ±15 psi
030PD = ±30 psi
060PD = ±60 psi
100PD = ±100 psi
150PD = ±150 psi
Gage
001PG = 0 psi to 1 psi
005PG = 0 psi to 5 psi
015PG = 0 psi to 15 psi
030PG = 0 psi to 30 psi
060PG = 0 psi to 60 psi
100PG = 0 psi to 100 psi
150PG = 0 psi to 150 psi
NB = Fastener
mount, dual axial
ports, same side
RN = Single
radial barbed
port
*
Pressure Range9
Options
N = No special options
60 mbar to 10 bar
Absolute
001BA = 0 bar to 1 bar
1.6BA = 0 bar to 1.6 bar
2.5BA = 0 bar to 2.5 bar
004BA = 0 bar to 4 bar
006BA = 0 bar to 6 bar
010BA = 0 bar to 10 bar
Differential
060MD = ±60 mbar
100MD = ±100 mbar
160MD = ±160 mbar
250MD = ±250 mbar
400MD = ±400 mbar
600MD = ±600 mbar
001BD = ±1 bar
1.6BD = ±1.6 bar
2.5BD = ±2.5 bar
004BD = ±4 bar
006BD = ±6 bar
010BD = ±10 bar
Gage
060MG = 0 mbar to 60 mbar
100MG = 0 mbar to 100 mbar
160MG = 0 mbar to 160 mbar
250MG = 0 mbar to 250 mbar
400MG = 0 mbar to 400 mbar
600MG = 0 mbar to 600 mbar
001BG = 0 bar to 1 bar
1.6BG = 0 bar to 1.6 bar
2.5BG = 0 bar to 2.5 bar
004BG = 0 bar to 4 bar
006BG = 0 bar to 6 bar
010BG = 0 bar to 10 bar
Figure 2. Completed Catalog Listing Example
NSCSANN100PGUNV Nominal 25 °C Output vs Pressure
20
18
Output (mV/V)
16
NSCSANN100PGUNV
SIP package, AN pressure port, no options,
100 psi gage, analog output, unamplified,
uncompensated, constant voltage
14
12
10
8
6
4
2
0
0
20
40
60
80
100
Pressure (psi)
Table 5. Pressure Types
Pressure Type
Absolute
Differential
Gage
Description
Output is proportional to the difference between applied pressure and a built-in reference to vacuum.
Reference pressure is absolute zero pressure (full vacuum).
Output is proportional to the difference between the pressures applied to each port. (Port 1 Port 2)
Reference pressure is Port 1 = Port 2.
Output is proportional to the difference between applied pressure and atmospheric (ambient)
pressure. Reference pressure is atmospheric pressure.
015PA
0
15
psi
30
60
N/A -6.0
030PA
0
30
psi
60
120 N/A -6.0
060PA
0
60
psi
100PA
0
100
150PA
0
150
Unit
Burst Pressure
Offset10
(mV/V)
Common Mode
Pressure
Pressure
Range
Over Pressure
Pressure Range
(see Figure 1)
Table 6. Pressure Range Specifications for 1 psi to 150 psi
Pmin. Pmax.
Sensitivity
TCO11
(mV/V/Full Scale (%FSS/25
C)
Span)
Min. Max. Min.
Nom.
Max.
TCS12
(%FSS/25 C)
Bridge
Resistance13
(kOhm)
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.
TCR14
(-40 C to
25 C)
(ppm/°C)
Min.
Max.
TCR15
(25 C to
85 C)
(ppm/°C)
Min.
Max.
Long-term
Stability
(1000 hr,
25 °C
[77 °F])
(%FSS)
Absolute
6.0 10.3 15.0 19.7 -3.6
0.0
3.6
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
6.0
14.8 19.7 -3.8
0.0
3.8
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
120 250 N/A -6.0
6.0 10.7 15.2 19.7 -3.5
0.0
3.5
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
psi
250 250 N/A -6.0
6.0
12.6 16.1 -4.1
0.0
4.1
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
psi
250 250 N/A -6.0
6.0 13.6 18.9 24.2 -2.8
0.0
2.8
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
9.9
9.1
Differential
001PD
-1
1
psi
5
20
150 -8.5
3.5
13.0 17.0 -1.1
0.5
1.1
-6.3 -5.0 -3.8
4
5
6
1200 2200 2200 3200
±0.35%
005PD
-5
5
psi
20
40
150 -8.5
3.5 20.0 30.0 40.0 -0.6
0.2
0.6
-6.3 -5.0 -3.8
4
5
6
1200 2200 2200 3200
±0.35%
015PD
-15
15
psi
30
60
150 -7.0
5.3 20.7 31.0 41.4 -0.6
0.3
0.5
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
030PD
-30
30
psi
60
120 150 -7.0
5.3 31.0 41.4 51.7 -0.3
0.2
0.3
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
060PD
-60
60
psi
120 250 250 -7.0
5.3 34.8 41.4 48.0 -0.3
0.2
0.3
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
100PD -100
100
psi
250 250 250 -7.0
5.3 29.0 34.5 40.0 -0.3
0.3
0.3
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
150PD -150
150
psi
250 250 250 -7.0
5.3 43.4 51.7 60.0 -0.2
0.2
0.2
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
9.0
Gage
001PG
0
1
psi
5
20
150 -8.5
3.5
-2.2
1.0
2.2
-6.3 -5.0 -3.8
4
5
6
1200 2200 2200 3200
±0.35%
005PG
0
5
psi
20
40
150 -8.5
3.6 10.0 15.0 20.0 -1.0
0.4
1.0
-6.3 -5.0 -3.8
4
5
6
1200 2200 2200 3200
±0.35%
015PG
0
15
psi
30
60
150 -7.0
5.3 10.3 15.5 20.7 -1.0
0.6
1.0
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
030PG
0
30
psi
60
120 150 -7.0
5.3 15.5 20.7 25.9 -0.6
0.4
0.6
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
060PG
0
60
psi
120 250 250 -7.0
5.3 17.4 20.7 24.0 -0.6
0.4
0.6
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
100PG
0
100
psi
250 250 250 -7.0
5.3 14.5 17.2 20.0 -0.7
0.5
0.7
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
150PG
0
150
psi
250 250 250 -7.0
5.3 21.7 25.9 30.0 -0.6
0.3
0.6
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2200 3200
±0.25%
4.5
6.5
8.5
Honeywell Sensing and Control
5
Table 7. Pressure Range Specifications for 60 mbar to 10 bar
10
12
TCS
(%FSS/25 C)
Bridge
13
Resistance
(kOhm)
TCR
(-40 C to
25 C)
(ppm/°C)
15
TCR
(25 C to
85 C)
(ppm/°C)
001BA
0
1
bar
2
4
N/A
-6.0
6.0
10.0 14.5 19.0 -3.8
0.0
3.8
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
1.6BA
0
1.6
bar
4.1
8
N/A
-6.0
6.0
7.7
11.4 15.2 -4.9
0.0
4.9
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
2.5BA
0
2.5
bar
4.1
8
N/A
-6.0
6.0
12.0 17.9 23.8 -3.1
0.0
3.1
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
004BA
0
4
bar
8
17
N/A
-6.0
6.0
10.3 14.7 19.0 -3.6
0.0
3.6
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
006BA
0
6
bar
17
17
N/A
-6.0
6.0
7.9
11.0 14.0 -4.8
0.0
4.8
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
010BA
0
10
bar
17
17
N/A
-6.0
6.0
13.2 18.3 23.4 -2.9
0.0
2.9
-7.5 -5.0 -3.0
2.6
3.5
4.4
500 1500 1500 2500
±0.25%
Unit
Common Mode
Pressure
Sensitivity
11
TCO
(mV/V/Full Scale (%FSS/25 C)
Span)
Burst Pressure
Offset
(mV/V)
Over Pressure
Pressure Range
(see Figure 1)
14
Pressure
Range
Pmin. Pmax.
Min. Max.
Min.
Nom. Max.
Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.
Min.
Max.
Min.
Max.
Long-term
Stability
(1000 hr,
25 °C
[77 °F])
(%FSS)
Absolute
Differential
060MD -60
60 mbar 340 1380 10000 -8.5
3.5
7.8
11.3 14.8 -1.3
0.6
1.3
-6.3 -5.0 -3.8
4
5
6
1200 2200 2220 3200
0.35%
100MD -100 100 mbar 340 1380 10000 -8.5
3.5
13.1 18.9 24.7 -0.8
0.3
0.8
-6.3 -5.0 -3.8
4
5
6
1200 2200 2220 3200
0.35%
160MD -160 160 mbar 340 1380 10000 -8.5
3.5
20.9 30.2 39.4 -0.5
0.2
0.5
-6.3 -5.0 -3.8
4
5
6
1200 2200 2220 3200
0.35%
250MD -250 250 mbar 1380 2760 10000 -8.5
3.5
14.5 21.8 29.0 -0.7
0.3
0.7
-6.3 -5.0 -3.8
4
5
6
1200 2200 2220 3200
0.35%
400MD -400 400 mbar 1380 2760 10000 -7.0
5.3
23.2 34.8 46.4 -0.4
0.2
0.4
-6.3 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.35%
600MD -600 600 mbar 2060 4100 10000 -7.0
5.3
12.0 18.0 24.0 -0.8
0.5
0.8
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
001BD
-1
1
bar
2
4
10
-7.0
5.3
20.0 30.0 40.0 -0.6
0.3
0.5
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
1.6BD
-1.6
1.6
bar
4.1
8
10
-7.0
5.3
24.0 32.0 40.0 -0.4
0.3
0.4
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
2.5BD
-2.5
2.5
bar
4.1
8
10
-7.0
5.3
37.5 50.0 62.5 -0.3
0.2
0.3
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
004BD -4.0
4.0
bar
8
17
17
-7.0
5.3
33.6 40.0 46.4 -0.3
0.2
0.3
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
006BD -6.0
6.0
bar
17
17
17
-7.0
5.3
25.2 30.0 34.8 -0.4
0.3
0.4
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
010BD -10.0 10
bar
17
17
17
-7.0
5.3
42.0 50.0 58.0 -0.2
0.1
0.2
-6.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
Gage
060MG
0
60 mbar 340 1380 10000 -8.5
3.5
3.9
5.7
7.4
-2.6
1.1
2.6
-6.3 -5.0 -3.8
4
5
6
1200 2200 2220 3200
0.35%
100MG
0
100 mbar 340 1380 10000 -8.5
3.5
6.5
9.4
12.3 -1.5
0.7
1.5
-6.3 -5.0 -3.8
4
5
6
1200 2200 2220 3200
0.35%
160MG
0
160 mbar 340 1380 10000 -8.5
3.5
10.4 15.1 19.7 -1.0
0.4
1.0
-6.3 -5.0 -3.8
4
5
6
1200 2200 2220 3200
0.35%
250MG
0
250 mbar 1380 2760 10000 -8.5
3.5
7.3
10.9 14.5 -1.4
0.6
1.4
-6.3 -5.0 -3.8
4
5
6
1200 2200 2220 3200
0.35%
400MG
0
400 mbar 1380 2760 10000 -7.0
5.3
11.6 17.4 23.2 -0.9
0.4
0.9
-6.3 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.35%
600MG
0
600 mbar 2060 4100 10000 -7.0
5.3
6.0
12.0 -1.7
1.0
1.7
-8.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.35%
001BG
0
1
bar
2
4
10
-7.0
5.3
10.0 15.0 20.0 -1.0
0.6
1.0
-8.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
1.6BG
0
1.6
bar
4.1
8
10
-7.0
5.3
12.0 16.0 20.0 -0.8
0.5
0.8
-8.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
2.5BG
0
2.5
bar
4.1
8
10
-7.0
5.3
18.8 25.0 31.3 -0.6
0.4
0.5
-8.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
004BG
0
4
bar
8
17
17
-7.0
5.3
16.8 20.0 23.2 -0.6
0.4
0.6
-8.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
006BG
0
6
bar
17
17
17
-7.0
5.3
12.6 15.0 17.4 -0.8
0.6
0.8
-8.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
010BG
0
10
bar
17
17
17
-7.0
5.3
21.0 25.0 29.0 -0.5
0.4
0.5
-8.0 -5.0 -3.8
2.4
3
5.5 1200 2200 2220 3200
0.25%
9.0
Notes:
10. Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or “zero”.
11. TCO (Thermal Effect on Offset): The deviation in offset due to changes in temperature over the specified temperature range, relative to offset measured
at 25 C.
12. TCS (Thermal Effect on Span): The deviation in full scale span due to changes in temperature over the specified temperature range, relative to full
scale span measured at 25 C.
13. Bridge Resistance: The resistance of the device measured across the power supply leads.
14. TCR (Thermal Coefficient of Resistance): The deviation in bridge resistance due to changes in temperature over the specified temperature range,
relative to bridge resistance measured at 25 C.
Table 8. Pinout for DIP and SMT Packages
Output Type
Pin 1
Pin 2
analog
GND
OUTPUT+
Table 9. Pinout for SIP Packages
Output Type
Pin 1
analog
GND
6
www.honeywell.com/sensing
Pin 3
Vsupply
Pin 4
OUTPUT-
Pin 2
OUTPUT+
Pin 5
NC
Pin 6
NC
Pin 3
Vsupply
Pin 7
NC
Pin 8
NC
Pin 4
OUTPUT-
Figure 3. DIP Pressure Port Dimensional Drawings (For reference only: mm [in])
DIP NN: No ports
8
7
6
DIP AN: Single axial barbed port
0,25
[0.010]
5,44
[0.214]
5
PORT 1
13,75
[0.541]
10,0
[0.39]
8
PORT 2
13,35
[0.525]
6,99
[0.275]
7
6
5
0,25
[0.010]
7,95
[0.313]
10,0
[0.39]
6,2
[0.24]
13,35
[0.525]
6,99
PORT 2 [0.275]
4,93 DIA.
[0.194]
PORT 1
1
2
3
1
4
2
9,24
[0.364]
10,85
[0.427]
2,54 TYP.
[0.100]
3
4
9,24
[0.364]
11,21
[0.441]
2,54 TYP.
[0.100]
8X 0,46
[0.018]
8X 0,46
[0.018]
DIP LN: Single axial barbless port
5,80
[0.228]
8
7
6
DIP RN: Single radial barbed port
0,25
[0.010]
10,0
[0.39]
5
8
7
6
2,47 DIA.
[0.097]
PORT 2
6,99
[0.275]
13,35
[0.525]
0,25
[0.010]
5,80
[0.228]
5
10,0
[0.39]
4,2
[0.17]
13,35
[0.525]
6,99
PORT 2
[0.275]
PORT 1
PORT 1
1
2
3
1,93 DIA.
[0.076]
4
9,24
[0.364]
2,54 TYP.
[0.100]
1
2
3
4
2,54 TYP.
[0.100]
11,21
[0.441]
13,75
[0.541]
6,95
[0.274]
9,24
[0.364]
11,21
[0.441]
1,00
[0.039]
8X 0,46
[0.018]
8X 0,46
[0.018]
DIP RR: Dual radial barbed ports, same side
4,0
[0.16]
8
7
6
5
PORT 1
PORT 1
PORT 2
,25
[0.010]
6,16
[0.242]
13,35
[0.525]
6,99
PORT 2
[0.275]
DIP DR: Dual radial barbed ports, opposite sides
15,76
[0.620]
10,0
[0.39]
2X 1,93 DIA.
[0.076]
8
7
6
5
2
3
4
2,54 TYP.
[0.100]
9,24
[0.364]
11,21
[0.441]
10,0
[0.39]
2X 1,93 DIA.
[0.076]
6,99
PORT 2 [0.275]
PORT 1
4,65
[0.183]
1
0,25
[0.010]
6,16
[0.242]
13,35
[0.525]
PORT 1
PORT 2
1
2
3
9,24
[0.364]
4
2,54 TYP.
[0.100]
3,78
[0.149]
11,21
[0.441]
3,78
[0.149]
8X 0,46
[0.018]
8X 0,46
[0.018]
Honeywell Sensing and Control
7
Figure 4. SMT Pressure Port Dimensional Drawings (For reference only: mm [in])
SMT NN: No ports
8
7
6
SMT AN: Single axial barbed port
13,75
[0.541]
10,0
[0.39]
5,44
[0.214]
5
8
6
5
10,0
[0.39]
7,95
[0.313]
13,4
[0.53]
6,99
PORT 2 [0.275]
PORT 1
7
4,93 DIA.
[0.194]
PORT 2
13,4
[0.53]
6,99
[0.275]
PORT 1
1
2
3
4
8X 0,46
[0.018]
4,80
[0.189]
6,41
[0.252]
2,54 TYP.
[0.100]
1
5,80
[0.228]
7
6
3
4
4,80
[0.189]
6,77
[0.266]
2,54 TYP.
[0.100]
SMT LN: Single axial barbless port
8
2
SMT RN: Single radial barbed port
10,0
[0.394]
5
8X 0,46
[0.018]
8
7
6
5,80
[0.228]
5
2,47 DIA.
[0.097]
13,35
[0.525]
6,99
PORT 2 [0.275]
PORT 1
10,0
[0.39]
4,2
[0.17]
13,3
[0.53]
6,99
PORT 2
[0.275]
PORT 1
1,93 DIA.
[0.076]
PORT 1
1
2
3
1
4
4,80
[0.189]
6,77
[0.266]
2,54 TYP.
[0.100]
8X 0,46
[0.018]
2
3
4
4,80
[0.189]
6,77
[0.266]
2,54 TYP.
[0.100]
8X 0,46
[0.018]
13,75
[0.541]
SMT RR: Dual radial barbed ports, same side
4,0
[0.16]
8
7
6
2X 1,93 DIA.
[0.076]
13,35
[0.525]
6,99
PORT 2
[0.275]
PORT 1
PORT 1
PORT 2
10,0
[0.39]
6,16
[0.242]
5
SMT DR: Dual radial barbed ports, opposite sides
2X 2,93
[0.115]
15,8
[0.62]
8
7
6
2X 1,93 DIA.
[0.076]
4,6
[0.18]
1
2
3
4
2,54 TYP.
[0.100]
13,4
[0.53]
6,99
[0.275]
PORT 2
PORT 1
4,80
[0.189]
6,77
[0.266]
3,78
[0.149]
8
10,0
[0.39]
6,16
[0.242]
5
www.honeywell.com/sensing
8X 0,46
[0.018]
1
2
3
4
2,54 TYP.
[0.100]
3,78
[0.149]
4,80
[0.189]
6,77
[0.266]
8X 0,46
[0.018]
Figure 5. SIP Package Dimensional Drawings (For reference only: mm [in])
SIP NN: No ports
SIP AA: Dual axial barbed ports, opposite sides
10,0
[0.39]
10,0
[0.39]
4,87
[0.192]
10,0
[0.39]
PORT 1
22,06
[0.869]
10,0
[0.39]
PORT 2
PORT 2
PORT 1
2X 4.93 DIA.
[0.194]
15,2
[0.60]
1
2
3
15,2
[0.60]
4
4X 0,51
[0.020]
1
0,25
[0.010]
2
3
2,54 TYP.
[0.100]
SIP AN: Single axial barbed port
10,0
[0.39]
PORT 1
0,25
[0.010]
10,0
[0.39]
13,75
[0.541]
10,0
[0.39]
PORT 2
2,47 DIA.
[0.097]
15,2
[0.60]
15,2
[0.60]
2
3
4
4X 0,51
[0.020]
PORT 2
PORT 1
4.93 DIA.
[0.194]
1
2,54 TYP.
[0.100]
SIP LN: Single barbless port
13,75
[0.541]
10,0
[0.39]
4
4X 0,51
[0.020]
1
0,25
[0.010]
2,54 TYP.
[0.100]
2
3
4
0,25
[0.010]
4X 0,51
[0.020]
2,54 TYP.
[0.100]
SIP FF: Fastener mount, dual axial barbed ports, opposite sides
27,20
[1.071]
29,48
[1.161]
23,12
[0.910]
10,44
[0.411]
17,78
[0.700]
PORT 2
PORT 1
2X 3.94 DIA.
[0.155]
2X 4,78 DIA.
[0.188]
20,16
[0.794]
1
0,25
[0.010]
4X 0,51
[.020]
2
3
4
2,54 TYP.
[0.100]
SIP FN: Fastener mount, single axial barbed port
29,48
[1.161]
16,38
[0.645]
23,12
[0.910]
17,78
[0.700]
PORT 2
2X 3.94 DIA.
[0.155]
PORT 1
4.78 DIA.
[0.188]
20,16
[0.794]
1
4X 0,51
[0.020]
0,25
[0.010]
2
3
4
2,54 TYP.
[0.100]
Honeywell Sensing and Control
9
Figure 5. SIP Package Dimensional Drawings (continued)
SIP GN: Ribbed fastener mount, single axial barbed port
27,96
[1.101]
21,60
[0.850]
16,51
[0.650]
19,06
[0.750]
PORT 2
PORT 1
2X 3,94 DIA.
[0.155]
4.78 DIA.
[0.188]
10,63
[0.418]
1
0,25
[0.010]
4X 0,51
[0.020]
2
3 4
2,54 TYP.
[0.100]
SIP NB: Fastener mount, dual axial ports, same side
27,31
[1.075]
25,3
[0.996]
21,60
[0.850]
2X 4,80 DIA.
[0.189]
PORT 2
2X 3.50 DIA.
[0.138]
22,87
[0.900]
PORT 1
13
[0.52]
4
3
2
1
0,25
[0.010]
4X 0,51
[0.020]
2,54 TYP.
[0.100]
SIP RN: Single radial barbed port
10,0
[0.39]
5,80
[0.228]
PORT 1
10,0
[0.39]
1,92 DIA.
[0.076]
PORT 2
15,2
[0.60]
1
2
3
4
4X 0,51
[0.020]
0,25
[0.010]
2,54 TYP.
[0.100]
SIP RR: Dual radial barbed ports, same side
10,0
[0.39]
6,16
[0.243]
PORT 1
10,0
[0.39]
PORT 2
2X 1,92 DIA.
[0.076]
15,2
[0.60]
1
2
3
4
4X 0,51
[0.020]
10
www.honeywell.com/sensing
0,25
[0.010]
2,54 TYP.
[0.100]
Figure 5. SIP Package Dimensional Drawings (continued)
SIP DR: Dual radial barbed ports, opposite side
SIP HH: Fastener mount, dual radial barbed ports, same side
29,62
[1.166]
15,8
[0.62]
10,0
[0.39]
6,16
[0.243]
10,58
[0.416]
6,64
[0.261]
23,12
[0.910]
PORT 2
10,0
[0.39]
PORT 2
PORT 1
PORT 1
PORT 2
PORT 1
28,96
[1.140]
2X 4.93 DIA.
[0.194]
15,2
[0.60]
1
2
3
4
4X 0,51
[0.020]
0,25
[0.010]
11,27
[0.444]
2,54 TYP.
[0.100]
4X 0,51
[0.020]
SIP HN: Fastener mount, single radial barbed port
23,12
[0.910]
0,25
[0.010]
2
3 4
2,54 TYP.
[0.100]
SIP MN: Manifold mount, outer diameter seal
7,97
[0.314]
4,78 DIA.
[0.188]
1
5,36
[0.211]
PORT 2
PORT 1
15,24 DIA.
[0.600]
PORT 1
28,96
[1.140]
PORT 2
12,5
[0.49]
2X 3,94 DIA.
[0.155]
11,27
[0.444]
1
4X 0,51
[0.020]
4X 0,51
[0.020]
2 3 4
0,25
[0.010]
0,25
[0.010]
1
2
3
4
2,54 TYP.
[0.100]
2,54 TYP.
[0.100]
SIP SN: Manifold mount, inner diameter seal
PORT 2
12,57
[0.495]
5,1
[0.20]
PORT 1
13,11
[0.516]
15,6
[0.61]
1
4X 0,51
[0.020]
2
3
4
2,54 TYP.
[0.100]
Honeywell Sensing and Control
11
WARNING
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. DO NOT USE this document as a
product installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Asia Pacific
Europe
Latin America
USA/Canada
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
008221-1-EN IL50 GLO Printed in USA