Copal JCL50 Conductive plastic rectilinear type Datasheet

CONDUCTIVE PLASTIC RECTILINEAR TYPE
JCL·JCL B series
Basic construction
Conductive plastic rectilinear type
RoHS compliant
■ FEATURES
O10 ~ 500 mm
OHigh resolution (Essentially infinite)
OLong life
OMounting plate seating position can be set to any positions (JCL B)
ORoHS compliant
■ PART NUMBER DESIGNATION
J C L 1 0 0 B
1 k
0 . 5 %
Series name
Independent linearity
JCL10, JCL20, JCL50, JCL100B
JCL200B, JCL300B, JCL500B
0.5 %:± 0.5 %
Nominal resistance value(Ω)
1 k, 2 k, 5 k, 10 k
■ LIST OF PART NUMBERS
Effective
electrical
travel
Item
10 mm
20 mm
50 mm
Nominal
resistance value
Part number
Effective
electrical
travel
Item
Nominal
resistance value
Part number
1 kΩ
JCL100B 1 k 0.5 %
2 kΩ
JCL100B 2 k 0.5 %
5 kΩ
JCL100B 5 k 0.5 %
1 kΩ
JCL10 1 k 0.5 %
2 kΩ
JCL10 2 k 0.5 %
5 kΩ
JCL10 5 k 0.5 %
1 kΩ
JCL20 1 k 0.5 %
10 kΩ
JCL100B 10 k 0.5 %
2 kΩ
JCL20 2 k 0.5 %
1 kΩ
JCL200B 1 k 0.5 %
2 kΩ
JCL200B 2 k 0.5 %
5 kΩ
JCL200B 5 k 0.5 %
100 mm
5 kΩ
JCL20 5 k 0.5 %
10 kΩ
JCL20 10 k 0.5 %
1 kΩ
JCL50 1 k 0.5 %
10 kΩ
JCL200B 10 k 0.5 %
2 kΩ
JCL50 2 k 0.5 %
2 kΩ
JCL300B 2 k 0.5 %
5 kΩ
JCL50 5 k 0.5 %
10 kΩ
JCL50 10 k 0.5 %
※ Verify the above part numbers when placing orders.
200 mm
300 mm
500 mm
5 kΩ
JCL300B 5 k 0.5 %
10 kΩ
JCL300B 10 k 0.5 %
5 kΩ
JCL500B 5 k 0.5 %
10 kΩ
JCL500B 10 k 0.5 %
JCL/JCL B
POTENTIOMETERS
■ STANDARD SPECIFICATIONS
Item
JCL
Part number
10
20
50
100B
± 0.5
%
Independent linearity
Effective electrical travel
mm
Mechanical travel
mm
Power rating (at 40 °C)
W
Dielectric strength
10
+1
0
20
+1
0
50
+1
0
100
+2
0
200
+2
0
300
0.13
0.25
0.6
1.5
1000
3
7
6 million
4 million
1 min
147 {15}
1960 {200}
N·m {kgf·cm} minimum
0.196 {2}
0.981 {10}
Temp. coefficient of resistance
500
mm/s
± 400
ppm/°C
−40 ~ 85
°C
Operating temp. range
20 million
cycle
g
Net weight
+3
0
4
mN {gf} maximum
Maximum traveling speed
500
1000 (at DC500 V)
MΩ minimum
Operating force
+3
0
Minimum effective electrical travel
Vrms
Insulation resistance
Life
500B
Essentially infinite
Resolution
Stop strength
300B
± 20
%
Resistance torelance
200B
Approx. 23
Approx. 27
Approx. 38
10 million
Approx. 182 Approx. 272 Approx. 373 Approx. 555
IP40
Protection grade
■ RATED POWER DERATING CURVE
Power rating ratio (%)
100
– 40
+ 40
Ambient temperature (C)
+ 85
JCL/JCL B
POTENTIOMETERS
■ OUTLINE DIMENSIONS
Unless otherwise specified, tolerance: ± 0.5 (Unit: mm)
OJCL10 ~ 50
5
1
15
φ3
D
18
1
3
2
When shaft inserted
Wiring
diagram
M2
3
2
2
2
13.4
7
3.3
5 10
A
JCL10 ~ 50
(3)
5
B
Part
number
2-M2
(Use with depth under 3)
Mark
JCL10
JCL20
JCL50
(C)
A
B
(C)
D
45
55
85
37
47
77
60
70
100
18
28
58
φ6
M4
22
10
Projection A
2
4.5
4-φ 3.5
B (Variable)
5
10
3
5
51
Mounting plate pitch
OJCL100B ~ 500B
13
C (Variable)
1
24
A
(D)
Projection A
JCL100B ~ 500B
Part
number
Mark
JCL100B
JCL200B
JCL300B
JCL500B
A
B
C
(D)
159
259
369
569
50 ~ 129
100 ~ 229
150 ~ 339
250 ~ 539
17 ~ 96
17 ~ 146
17 ~ 206
17 ~ 306
178.5
278.5
388.5
588.5
B dimensions require minimum 1/2 of effective electrical length.