Click on Series name for product info on aimtec.com Series AM2DC-Z 2 Watt | DC-DC Converter FEATURES: RoHS compliant SIP7 package High efficiency up to 82% I/O Isolation 6000 VDC Low coupling capacity Physical clearance of Isolation barrier 6mm Safety barrier 100% production tested Rated working voltage of 250 Vrms Continuous Short Circuit Protection Models Single output Input Voltage (V) Output Voltage (V) Output Current Max (mA) Max Capacitive Load (uF) Efficiency (%) 5 5 5 5 5 12 12 12 12 12 15 15 15 15 15 24 24 24 24 24 3.3 5 9 12 15 3.3 5 9 12 15 3.3 5 9 12 15 3.3 5 9 12 15 600 400 222 167 133 600 400 222 167 133 600 400 222 167 133 600 400 222 167 133 1000 470 470 220 220 1000 470 470 220 220 1000 470 470 220 220 1000 470 470 220 220 73 78 80 80 82 73 78 80 80 82 73 78 80 80 82 73 78 80 80 82 Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Max Capacitive Load (uF) Efficiency (%) AM2DC-0503DH60Z AM2DC-0505DH60Z AM2DC-0509DH60Z AM2DC-0512DH60Z AM2DC-0515DH60Z AM2DC-051509DH60Z AM2DC-1203DH60Z AM2DC-1205DH60Z AM2DC-1209DH60Z AM2DC-1212DH60Z AM2DC-1215DH60Z AM2DC-121509DH60Z AM2DC-1503DH60Z AM2DC-1505DH60Z AM2DC-1509DH60Z AM2DC-1512DH60Z AM2DC-1515DH60Z AM2DC-151509DH60Z 5 5 5 5 5 5 12 12 12 12 12 12 15 15 15 15 15 15 ±3.3 ±5 ±9 ±12 ±15 +15/-9 ±3.3 ±5 ±9 ±12 ±15 +15/-9 ±3.3 ±5 ±9 ±12 ±15 +15/-9 ±300 ±200 ±111 ±83 ±67 +67/-111 ±300 ±200 ±111 ±83 ±67 +67/-111 ±300 ±200 ±111 ±83 ±67 +67/-111 ±470 ±220 ±220 ±100 ±100 +100/-220 ±470 ±220 ±220 ±100 ±100 +100/-220 ±470 ±220 ±220 ±100 ±100 +100/-220 73 78 80 80 82 72 73 78 80 80 82 72 73 78 80 80 82 72 Model AM2DC-0503SH60Z AM2DC-0505SH60Z AM2DC-0509SH60Z AM2DC-0512SH60Z AM2DC-0515SH60Z AM2DC-1203SH60Z AM2DC-1205SH60Z AM2DC-1209SH60Z AM2DC-1212SH60Z AM2DC-1215SH60Z AM2DC-1503SH60Z AM2DC-1505SH60Z AM2DC-1509SH60Z AM2DC-1512SH60Z AM2DC-1515SH60Z AM2DC-2403SH60Z AM2DC-2405SH60Z AM2DC-2409SH60Z AM2DC-2412SH60Z AM2DC-2415SH60Z Models Dual output www.aimtec.com F 051e R6 Tel: +1 514 620 2722 1 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2DC-Z 2 Watt | DC-DC Converter Models Dual output (continued) Model Input Voltage (V) Output Voltage (V) Output Current max (mA) Max Capacitive Load (uF) Efficiency (%) AM2DC-2403DH60Z AM2DC-2405DH60Z AM2DC-2409DH60Z AM2DC-2412DH60Z AM2DC-2415DH60Z AM2DC-241509DH60Z 24 24 24 24 24 24 ±3.3 ±5 ±9 ±12 ±15 +15/-9 ±300 ±200 ±111 ±83 ±67 +67/-111 ±470 ±220 ±220 ±100 ±100 +100/-220 73 78 80 80 82 72 Input Specifications Parameters Voltage range Filter Startup time Nominal Typical 5 12 15 24 4.5-5.5 10.8-13.2 13.5-16.5 21.6-26.4 Maximum Units VDC Capacitor Absolute Maximum Rating Vnom, constant resistive load 5 Vin 12 Vin 15 Vin 24 Vin 20 5 Vin 12 Vin 15 Vin 24 Vin See the suggested circuit 70 40 30 20 20 Conditions Typical ms 0-7 0-15 0-18 0-28 100 Peak Input Voltage time Quiescent Current Input Reflected Ripple current VDC ms mA mA p-p Isolation Specifications Parameters Tested I/O voltage (rated for 1 min) Rated working voltage 60 sec Reinforced Insulation, 1 x MOPP Reinforced Insulation, 2 x MOPP Resistance Capacitance Rated Units 6000 VDC 250 125 >1000 10 V rms MOhm pF Output Specifications Parameters Voltage accuracy Short Circuit protection Short circuit restart Line voltage regulation Load voltage regulation Cross Regulation (dual output) Temperature coefficient Ripple and Noise* Conditions Typical Maximum ±3 Continuous Auto recovery For 1% change of V in ±1.2 From 10 to 100% load ±10 25% to 100% one load & 100% other load ±4 ±0.03 20MHz Bandwidth Units % 100 % % % %/oC mV p-p *Output ripple and noise are measured with external connection of 10uF electrolytic capacitor and 1uF ceramic capacitor. www.aimtec.com F 051e R6 Tel: +1 514 620 2722 2 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2DC-Z 2 Watt | DC-DC Converter General Specifications Parameters Switching frequency Creepage and Clearance Distance Operating temperature Storage temperature Maximum case temperature Cooling Humidity Case material Soldering temperature Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load, depending of the model Input to Output Full Load without Derating 50 - 100 >6 Maximum -40 to +85 -40 to +125 100 Units KHz mm oC oC oC Free air convection 95 Non-conductive black plastic, epoxy encapsulated (UL94V-0 rated) 1.5mm from case for 10 sec. 260 4.2 0.77 x 0.39 x 0.49 inches 19.56 x 9.80 x 12.50 mm >2 390 000 hrs (MIL-HDBK-217 F at +25 oC) % RH oC g NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters EN 55022: 2010, Class B EN 55024: 2010 IEC 61000-4-2: 2008, Criteria A IEC 61000-4-3: 2010, Criteria A IEC 61000-4-4: 2012, Criteria A (with external circuit) IEC 61000-4-6: 2008, Criteria A IEC 61000-4-8: 2009, Criteria A Designed to meet IEC/EN 60950-1 & IEC/EN 60601-1 Standards Pin Out Specifications Pin 1 2 5 6 7 19.5 (0.77) 6000 VDC Single + V Input - V Input - V Output No pin + V Output Dual + V Input - V Input - V Output Common + V Output Dimensions 9.8 (0.39) PRINTED FACE 12.0 (0.47) 0.50 (0.02) 3.00 (0.12) 2.54 (0.10) 15.24 (0.60) 0.50 (0.02) 9.8 (0.39) NOTE: Unit:mm [inch] Pin Diameter: 0.50 ± 0.05mm [0.02 ± 0.002 inch] Pin Pitch tolerance: ±0.35mm [ ±0.014 inch] Case tolerance: ±0.50mm [ ±0.02 inch]Pin Out Specifications 0.3(0.01) 2.40 (0.09) www.aimtec.com F 051e R6 0.50 (0.02) Tel: +1 514 620 2722 3 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM2DC-Z 2 Watt | DC-DC Converter Input Reflected Ripple Current Test Circuit Recommended Application circuit for reducing the output ripple and noises: Recommended Output Capacitor to reduce the converter’s ripple and noises for single output models is 4.7µF to 100µF and for dual output models is 4.7µF to 68µF connected to both outputs. Li with value of 12µH and Ci with value 10µF to 100µF are recommended to be connected to the input of the converter for EMI improvement. EMI Filter Circuit recommendation Vin C1 5, 12, 15 V 470 µF / 100V 24 V 470 µF / 100V * Electrolytic type L1 C2 C3 18 µH 18 µH 2.2 µF / 100V 470 pF / 2kV NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R6 Tel: +1 514 620 2722 4 of 4 Toll free: + 1 888 9 AIMTEC (924 6832) North America only