Frequency D100BP2/5 2 - pole pair band - pass filter Datasheet

D100B Series
100 Hz to 100 kHz
Low Noise Fixed Frequency
2 – Pole Pair
Band - Pass Filters
Description:
The D100B Series are low noise and distortion 2pole-pair, fixed center frequency (fo) band-pass
filters. These filters feature near theoretical low
noise and distortion performance, by providing up
to -120 dB noise floors (20-Bit). D100B’s take
advantage of FDI’s design expertise utilizing high
performance amplifiers and surface-mount
technology to provide design engineers with
precision signal conditioning solutions in a
compact package. These fully self-contained
units require no external components or
adjustments. Each D100B comes factory tuned
to a user specified corner frequency between 100
Hz to 100 kHz. Available Q’s for D100B models
are 1, 2 or 5 and operate with low harmonic
distortion over an input voltage range to ±10 V.
Features/Benefits:
• Small 32-pin DIP (1.8"L x 0.8"W) footprint
minimizes board space requirements.
• Plug-in ready-to-use, reducing engineering
design and manufacturing cycle time.
• Factory tuned, no external clocks or
adjustments needed.
• Broad range of center frequencies to meet a
wide range of applications.
Available Band-Pass Models:
D100BP2
2-Pole Pair
Page
2
General Specifications
Pin-out/package data & order information
3
Applications
•
•
•
•
•
Transducer output filtering.
Production test instrumentation
Medical electronics equipment and research
Noise and harmonic analysis
Frequency spectrum analysis
1
1784 Chessie Lane, Ottawa, IL 61350 • Tel: 800/252-7074, 815/434-7800 • FAX: 815/434-8176
e-mail: [email protected] • Web Address: http://www.freqdev.com
D100B Series
100 Hz to 100 kHz
Low Noise Fixed Frequency
Model
Product Specifications
D100BP2
Size
1.8” x 0.8” x 0.3”
Range fo
100 Hz to 100 kHz
Available “Q’s” 1
1, 2 or 5
“Q” Accuracy
±10 %
Theoretical Transfer
Characteristics
Appendix A
Pages 39 & 40
Pass-Band Gain
(non-inverting)
0 ± 0.2 dB typ.
0 ± 0.4 dB max.
Attenuation Rate
12 dB/octave
Center Frequency
Stability
± 1% max.
fo
± 0.01%/°C
(THD) Total Harmonic
Distortion @ 10 Vp-p
FO ≤100 Hz
FO ≤20 kHz
FO ≤100 kHz
<-120 dB max.
<-117 dB max.
<-100 dB max.
2 – Pole Pair
Band - Pass Filters
Narrow Band Noise
100 kHz BW @ 20V p-p
FO ≤100 Hz
FO ≤20 kHz
FO ≤100 kHz
(µV rms)
7.0 typ., 12 max.
22 typ., 40 max.
70 typ., 100 max.
Filter Mounting 2
Assembly
FMA-01S
1. Q – Quality Factor for band-pass and band-reject filters. Q = fO/(fH-fL), fo = fHfL
2. Use I/O jumpers to bypass input and output buffers, for low noise operation. With FMA, D100B distortion specs at
50k to 100kHz may degrade slightly.
2
1784 Chessie Lane, Ottawa, IL 61350 • Tel: 800/252-7074, 815/434-7800 • FAX: 815/434-8176
e-mail: [email protected] • Web Address: http://www.freqdev.com
D100B Series
Specifications
Pin-Out and Package Data
Ordering Information
(25ºC and Vs ± 15 Vdc)
Offset Temp. Coefficient
1.0 k Ω min.
±5V
±10V
10 mA max.
2 mV typ.
20 mV max.
50 µV/°C
Power Supply (±Vs)
Rate Voltage
Operating Range
Quiescent Current
±15V
±5V min. ±18V max.
40 mA max
Temperature Range
Operating
Storage
FO <10 kHz
0.50"(max)
FO >10 kHz
0.30"(max)
0.15" (min)
0.025" (dia)
1.80"(max)
FO <10 kHz
FO >10 kHz
All dimensions are in inches
All case dimensions ± 0.01"
0.10"(typ)
0.80"
0.70"
1
5
15 16
OUT
+VS
-VS OS
0ºC to +70ºC
-25ºC to +85ºC
Bottom View
+Vs
0.15"
0.00"
0.10"
0.00"
GND
IN
29
17
0.45"
0.55"
DC Offset Adjustment
1.80"
Analog Output Characteristics
Load Impedance
Linear Operating Range for THD
Operating Range for Low Noise
2
Current @ (Vs @ ±15V)
Offset Voltage3
0.80"(max)
1.0 kΩ min.
±10 Vpeak
±Vs
1.55"
1.65"
Analog Input Characteristics1
Impedance
Voltage Range
Max. Safe Voltage
Do not connect
if trim is not
required.
20 k
ORDERING INFORMATION
Os
(Cermet)
4
D100BP2/5-10.0 kHz
-Vs
Notes:
1. Input and output signal voltage referenced to supply common.
2. Output is short circuit protected to common. DO NOT CONNECT
TO ±Vs.
3. Adjustable to zero.
4. Units operate with or without offset pin connected.
5. How to specify Center Frequency F0. Center frequency is
specified by attaching a three-digit frequency designator to the basic
model number. Center frequencies can range from 100 Hz to 100
kHz.
“Q”
1, 2, 5
F0 Center Frequency
e.g.,
849 Hz
2.50 kHz
33.3 kHz
5
We hope the information given here will be helpful. The information is based on data and our best knowledge, and we consider the information to
be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale, which apply,
to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations or suggestions, nor do we intend them
as a recommendation for any use, which would infringe any patent or copyright.
PR-D100BP2
3
1784 Chessie Lane, Ottawa, IL 61350 • Tel: 800/252-7074, 815/434-7800 • FAX: 815/434-8176
e-mail: [email protected] • Web Address: http://www.freqdev.com
Band-Pass
2-Pole Pair
Appendix A
0
-10
-20
-30
-40
-50
-60
-70
-80
0.1
0
Q1
Q2
Amp (dB)
Amp (dB)
Amplitude Response Curves
Q5
Q10
Q1
-1
Q2
-2
Q5
-3
-4
Q10
2
3 4 5 6 78
1.0 2 3 4 5 6 7 8 10.0
Normalized Frequency (f/fo)
Q=1
Amp
(dB)
-0.10
-0.25
-0.50
-1.00
-1.50
-2.00
-2.50
-3.00
-5.00
-10.00
-15.00
-20.00
-25.00
-30.00
-35.00
-40.00
-45.00
-50.00
-55.00
-60.00
-65.00
-70.00
-75.00
-80.00
fL < fO < fH
f /fO
0.824
0.783
0.747
0.705
0.677
0.654
0.635
0.618
0.563
0.457
0.368
0.290
0.225
0.173
0.131
0.099
0.075
0.056
0.042
0.032
0.024
0.018
0.013
0.010
f /fO
1.214
1.277
1.338
1.418
1.478
1.529
1.574
1.617
1.776
2.189
2.720
3.445
4.439
5.795
7.630
10.09
13.41
17.83
23.75
31.65
42.19
56.25
75.00
100.0
Q=2
0.7
0.8
Q=5
fL < fO < fH
f /fO
0.907
0.884
0.863
0.837
0.820
0.805
0.792
0.781
0.742
0.657
0.572
0.485
0.399
0.319
0.250
0.193
0.147
0.111
0.084
0.063
0.047
0.036
0.027
0.020
-5
0.6
fL < fO < fH
f /fO
1.102
1.131
1.159
1.194
1.220
1.242
1.262
1.280
1.348
1.523
1.748
2.062
2.506
3.130
3.999
5.192
6.814
9.002
11.94
15.87
21.13
28.15
37.52
50.01
f /fO
0.962
0.952
0.943
0.931
0.923
0.916
0.910
0.905
0.886
0.842
0.792
0.733
0.664
0.585
0.500
0.414
0.333
0.262
0.202
0.154
0.117
0.088
0.066
0.050
f /fO
1.040
1.051
1.061
1.074
1.083
1.091
1.098
1.105
1.129
1.188
1.263
1.364
1.507
1.709
2.000
2.414
3.001
3.819
4.945
6.479
8.552
11.33
15.06
20.05
0.9
1.0 1.1 1.2 1.3 1.4 1.5 1.6
Normalized Frequency (f/fo)
Q = 10
fL < fO < fH
f /fO
0.981
0.976
0.971
0.965
0.961
0.957
0.954
0.951
0.941
0.917
0.889
0.855
0.811
0.758
0.693
0.618
0.535
0.449
0.365
0.290
0.225
0.172
0.131
0.099
f /fO
1.020
1.025
1.030
1.036
1.041
1.045
1.048
1.051
1.062
1.090
1.125
1.170
1.233
1.320
1.443
1.618
1.869
2.228
2.737
3.453
4.443
5.798
7.632
10.10
39
1784 Chessie Lane, Ottawa, IL 61350 • Tel: 800/252-7074, 815/434-7800 • FAX: 815/434-8176
e-mail: [email protected] ∑Web Address: http://www.freqdev.com ∑
Band-Pass
2-Pole Pair
Appendix A
Phase Response Curves
180
180
Phase (deg)
Phase (deg)
Q10
90
0
Q1
Q2
-90
90
0
Q1
Q2
-90
Q5
Q10
-180
0.1
2
3 4 5 6 78
1.0 2 3 4 5 6 7 8 10.0
Normalized Frequency (f/fo)
-180
0.6
0.7
0.8
Q5
0.9
1.0 1.1 1.2 1.3 1.4 1.5 1.6
Normalized Frequency (f/fo)
Normalized Theoretical Phase Data
Phase
Mag
(deg)
1.0
2.5
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
60.0
70.0
80.0
90.0
105.0
120.0
135.0
150.0
165.0
180.0
Q=1
(+)
(-)
f /fO f /fO
0.994 1.006
0.985 1.016
0.970 1.031
0.940 1.063
0.913 1.096
0.886 1.128
0.861 1.161
0.838 1.194
0.815 1.227
0.794 1.259
0.774 1.292
0.755 1.324
0.719 1.391
0.685 1.460
0.652 1.535
0.618 1.618
0.564 1.772
0.502 1.991
0.424 2.356
0.320 3.126
0.177 5.639
0
inf
Q=2
(+)
(-)
f /fO f /fO
0.997 1.003
0.992 1.008
0.985 1.016
0.970 1.031
0.955 1.047
0.941 1.062
0.928 1.078
0.915 1.093
0.902 1.108
0.891 1.123
0.879 1.138
0.868 1.152
0.846 1.182
0.825 1.212
0.803 1.245
0.781 1.281
0.743 1.346
0.695 1.439
0.628 1.594
0.520 1.923
0.327 3.058
0
inf
Q=5
(+)
(-)
f /fO f /fO
0.999 1.001
0.997 1.003
0.994 1.006
0.988 1.012
0.982 1.018
0.976 1.025
0.970 1.030
0.965 1.036
0.960 1.042
0.955 1.048
0.950 1.053
0.945 1.059
0.935 1.069
0.925 1.081
0.916 1.092
0.905 1.105
0.887 1.128
0.862 1.160
0.825 1.212
0.758 1.319
0.593 1.686
0
inf
Q = 10
(+)
(-)
f /fO f /fO
0.999 1.001
0.998 1.002
0.997 1.003
0.994 1.006
0.991 1.009
0.988 1.012
0.985 1.015
0.982 1.018
0.980 1.021
0.977 1.024
0.974 1.026
0.972 1.029
0.967 1.034
0.962 1.040
0.957 1.045
0.951 1.051
0.941 1.062
0.928 1.077
0.908 1.101
0.869 1.150
0.764 1.310
0
inf
40
1784 Chessie Lane, Ottawa, IL 61350 • Tel: 800/252-7074, 815/434-7800 • FAX: 815/434-8176
e-mail: [email protected] ∑Web Address: http://www.freqdev.com ∑