B04AF THRU B04MF DC COMPONENTS CO., LTD. R RECTIFIER SPECIALISTS TECHNICAL SPECIFICATIONS OF SINGLE-PHASE SURFACE MOUNT BRIDGE RECTIFIER VOLTAGE RANGE - 50 to 1000 Volts CURRENT - 0.4 Ampere FEATURES * * * * * * Ideal for automated placement Low profile space Low forward voltage grop Low leakage current High forward surge capability Glass passivated junction MBF .106(2.70) .090(2.30) MECHANICAL DATA * * * * * * Case: Molded plastic Epoxy: UL 94V-0 rate flame retardant Terminals: MIL-STD-202E, Method 208 guaranteed Polarity: Symbols molded or marked on body Mounting position: Any Weight: 0.12 gram .043(1.10) .020(0.50) .276(7.00) .260(6.60) .236(6.00) .220(5.60) .004(0.10) Max. .016(0.41) .006(0.15) .035(0.90) .020(0.50) .197(5.00) .181(4.60) .063(1.60) .047(1.20) MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%. Dimensions in inches and (millimeters) SYMBOL B04AF B04BF B04DF B04GF B04JF B04KF B04MF UNITS Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 Volts Maximum RMS Bridge Input Voltage VRMS 35 70 140 280 420 560 700 Volts Maximum DC Blocking Voltage VDC 50 100 200 400 600 800 1000 Maximum Average Forward Output Current Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC Method) 0.4 Amps I FSM 15 Amps VF 1.1 Volts Maximum DC Forward Voltage Drop per Bridge Element at 0.4A DC o Maximum Reverse Current at rated @T A = 25 C DC Blocking Voltage per element @T A = 125 o C Typical Junction Capacitance ( Note1) Typical Thermal Resistance (Note 2) Operating and Storage Temperature Range NOTES : 1. Measured at 1 MHZ and applied reverse voltage of 4.0 volts. 2. On FR-4 P.C.B. with 0.035 x0.06" (0.9x1.5mm) copper pads. Volts IO IR 5.0 µAmps 100 CJ 13 RθJ A 120 T J, T STG -55 to + 150 pF 0 C/W 0 C RATING AND CHARACTERISTIC CURVES (B04AF THRU B04MF) FIG. 1 - DERATING CURVE FOR OUTPUT CURRENT PEAK FORWARD SURGE CURRENT, (A) AVERAGE FORWARD CURRENT, (A) 0.5 0.4 0.3 0.2 0.1 Single Phase Half Wave 60Hz Resistive or Inductive Load 0 0 30 60 90 FIG. 2 - MAXIMUM NON-REPETITIVE PEAK FORWARD SURGE CURRENT 120 30 8.3ms Single Half Sine-Wave JEDEC Method 25 20 15 10 5 0 150 1 10 AMBIENT TEMPERATURE, (oC) NUMBER OF CYCLES AT 60 Hz 10 1.0 TJ = 25OC 0.1 Pulse Width = 300 µS 1% Duty Cycle 0.01 .4 .6 .8 1.0 1.2 INSTANTANEOUS FORWARD VOLTAGE, (V) FIG. 4 - TYPICAL REVERSE CHARACTERISTICS INSTANTANEOUS REVERSE CURRENT, (uA) INSTANTANEOUS FORWARD CURRENT, (A) FIG. 3 - TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS .2 100 TJ= 125oC 10 1.0 TJ= 75oC .01 TJ= 25oC 0.01 10 20 40 60 80 100 120 PERCENT OF RATED PEAK REVERSE VOLTAGE, (%) DC COMPONENTS CO., LTD. R 100 140