SANYO SB10-18

Ordering number:EN2585B
SB10-18
Schottky Barrier Diode (Twin Type · Cathode Common)
80V, 1A Rectifier
Applications
Package Dimensions
· High frequency rectification (switching regulators,
converters, choppers).
unit:mm
1159B
[SB10-18]
Features
· Low forward voltage (VF max=0.85V).
· Fast reverse recovery time (trr max=35ns).
· Low switching noise.
· Low leakage current and highly reliability due to
highly reliable planar structure.
1:Anode
2:Cathode
3:Anode
JEDEC:TO-220AB
EIAJ:SC-46
Specifications
Absolute Maximum Ratings at Ta = 25˚C
Parameter
Symbol
Repetitive Peak Reverse Voltage
Nonrepetitive Peak Reverse Surge Voltage
Conditions
Ratings
Unit
VRRM
VRSM
Average Output Current
IO
Surge Forward Current
IFSM
Junction Temperature
Storage Temperature
180
V
190
V
1
A
50Hz, resistive load, Tc=114˚C
50Hz sine wave, 1 cycle
30
A
Tj
–55 to +125
˚C
Tstg
–55 to +125
˚C
Electrical Characteristics
Parameter
Symbol
Conditons
Ratings
min
typ
max
Reverse Voltage
VR
IR=0.5mA, Tj=25˚C, *
Forward Voltage
VF
IR
IF=0.4A, Tj=25˚C, *
0.85
V
VR=90V, Tj=25˚C, *
0.1
mA
trr
IF=2A, Tj=25˚C, *,–dIF/dt=10A/µs
Junction-Case:Smoothed DC
35
ns
5.0
˚C/W
Reverse Current
Reverse Recovery Time
Thermal Resistance
Rthj-c
180
Unit
V
Note*: Value per element
Electrical Connection
1:Anode
2:Cathode
3:Anode
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquaters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
43098HA (KT)/1228AT, TS No.2585-1/3
SB10-18
No.2585-2/3
SB10-18
No products described or contained herein are intended for use in surgical implants, life-support systems,
aerospace equipment, nuclear power control systems, vehicles, disaster/crime-prevention equipment and
the like, the failure of which may directly or indirectly cause injury, death or property loss.
Anyone purchasing any products described or contained herein for an above-mentioned use shall:
Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates,
subsidiaries and distributors and all their officers and employees, jointly and severally, against any
and all claims and litigation and all damages, cost and expenses associated with such use:
Not impose any responsibilty for any fault or negligence which may be cited in any such claim or
litigation on SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors or any of
their officers and employees jointly or severally.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume production. SANYO believes information herein is accurate and reliable, but no guarantees
are made or implied regarding its use or any infringements of intellectual property rights or other rights of
third parties.
This catalog provides information as of April, 1998. Specifications and information herein are subject to
change without notice.
PS No.2585-3/3