TSC SB105G

SB101G THRU SB107G
Single Phase 10.0 AMPS. Glass Passivated Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
10.0 Amperes
SB-10
Features
UL Recognized File # E-96005
Glass passivated junction
Surge overload rating 175 amperes peak
Low forward voltage drop
High temperature soldering guaranteed:
260℃ / 10 seconds / 0.375” ( 9.5mm )
lead length at 5 lbs., ( 2.3 kg ) tension
Small size, simple installation
Weight: 5 grams
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol SB
SB
Type Number
101G 102G
Maximum Recurrent Peak Reverse Voltage
VRRM
50 100
Maximum RMS Voltage
VRMS
35
70
Maximum DC Blocking Voltage
VDC
50 100
Maximum Average Forward Rectified Current
@TA = 50℃
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@ 5.0A
Maximum DC Reverse Current @ TA=25℃
at Rated DC Blocking Voltage @ TA=125℃
Typical Thermal Resistance (Note)
Operating Temperature Range
SB
SB
SB
SB
SB Units
103G 104G 105G 106G 107G
200
140
200
400
280
400
600
420
600
800 1000
560 700
800 1000
V
V
V
I(AV)
10.0
A
IFSM
175
A
VF
1.1
V
5
500
5
-55 to +150
-55 to +150
uA
uA
℃/W
℃
℃
IR
RθJC
TJ
TSTG
Note: Thermal Resistance from Junction to Case per Leg.
Storage Temperature Range
- 756 -
RATINGS AND CHARACTERISTIC CURVES (SB101G THRU SB107G)
FIG.2- MAXIMUM FORWARD CURRENT DERATING
CURVE
FIG.1- MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT PER BRIDGE ELEMENT
12
AVERAGE FORWARD CURRENT. (A)
PEAK FORWARD SURGE CURRENT. (A)
350
300
8.3ms Single Half Sine Wave
250
200
150
100
50
0
1
2
5
10
20
50
10
8
6
4
2
0
100
MOUNTED ON 4X4 INCH
COPPER PC BOARD
0.5"(12.7mm) LEAD LENGTH
0
50
150
100
o
AMBIENT TEMPERATURE. ( C)
NUMBER OF CYCLES AT 60Hz
FIG.3- TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS PER BRIDGE ELEMENT
100
FIG.4- TYPICAL REVERSE CHARACTERISTICS
PER BRIDGE ELEMENT
100
INSTANTANEOUS REVERSE CURRENT. ( A)
INSTANTANEOUS FORWARD CURRENT. (A)
40
20
10
4
2
1
0
Tj=25 C
PULSE WIDTH-300 S
0.4
TJ=125 0C
10
1
0.2
0.1
TJ=25 0C
0.6
0.7
0.8
0.9
1.0
1.1
1.2
0.1
1.3
INSTANTANEOUS FORWARD VOLTAGE. (V)
0
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
- 757 -
140