UTC-IC M2110

UTC M2110
LINEAR INTEGRATED CIRCUIT
MONAURAL MIC AMP. FOR
VIDEO CAMERA
DESCRIPTION
The UTC M2110 is a monaural microphone
TSSOP-8
amplifier for video camera. It can operate from 2.7V.
The performance is low operating current and
small package. Therefore it is easy to design the
downsizing and low consumption.
FEATURES
SOP-8
*Operating Voltage: 2.7V~5.3V
+
*Low Operating Current: V =5V, 3.5mA (Typ,)
V+=3.3V, 1.1mA (Typ.)
*Short Circuit Protection for External MIC.
PIN CONFIGURATION
MIC V+
EXT MIC V+
+VIN
GND
1
8
2
7
AMP OUT
3
6
AMP NFB
4
5
V+
-VIX
M2110
BLOCK DIAGRAM
V+
AMP O UT
8
7
AMP NFB
6
100k Ω
-V IN
5
13.7k Ω
AMP
+
444k Ω
MIC V
+
1
MIC Vcc
UTC
EXT
MIC V +
2
EXT MIC V
+
3
4
+V IN
G ND
UNISONIC TECHNOLOGIES CO., LTD.
1
QW-R122-003,A
UTC M2110
LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATINGS (Ta=25°C)
PARAMETER
SYMBOL
V+
PD
Supply Voltage
Power Dissipation
TSSOP-8
SOP-8
Operating Temperature Range
Storage Temperature Range
RATINGS
UNIT
7.0
V
mW
250
300
-20 ~+75
-40 ~+125
Toper
Tstg
°C
°C
ELECTRICAL CHARACTERISTICS (V+= 5V,Ta=25°C,unless otherwise specified)
PARAMETER
SYMBOL
Operating Current 1
Operating Current 2
Transfer Gain
Total Harmonic Distortion
Maximum Output Voltage
Output Noise Voltage
Input Resistance Gain
Output Resistance
Icc 1
Icc 2
Gv
THD
Vom
Vno
Zin
Zo
MIC Output Supply Voltage 1
MIC Output Supply Voltage 2
External Output Supply Voltage
Output Short Circuit Current
MICo 1
MICo 2
EXTout
Ios
TEST CONDITION
V+= 3.3V
f=1KHz
Vo=300mVrms, RL=10kΩ, f=1KHz
V+= 2.7V, RL=10kΩ, f=1kHz,THD=1%
Rg=1kΩ,C =0.1µF,A-Weight
f=1kHz
f=1kHz
MIN
27
2.0
2.0
2.0
4.0
V+= 2.7V
Io=25mA
EXTo=0V
TYP
MAX
UNIT
3.5
1.1
28
0. 05
2.5
30
110
10
4.5
2.0
29
0.2
2.35
2.25
2.7
2.5
mA
mA
dB
%
Vp-p
µVrms
kΩ
Ω
V
V
V
mA
42
30
TEST CIRCUIT
AMP O UT
0.1 μF
V+
Electret
Condenser
MIC.
8
7
6
1
2
3
1 μF
5
RL
10k Ω
4
EXT MIC
Vcc O UT
2.2k Ω
1
0.1 μF
47 μF
2*
0.1 μF
Rg
1k Ω
G ND
*SW 2 :O utput Noise Voltage Test
UTC
UNISONIC TECHNOLOGIES CO., LTD.
2
QW-R122-003,A
UTC M2110
LINEAR INTEGRATED CIRCUIT
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UTC
UNISONIC TECHNOLOGIES CO., LTD.
3