COILCRAFT DA2077-AL

Document 518
Flyback Transformer
For ON Semiconductor
NCP1027
The DA2077-AL flyback transformer has been specifically developed for use with ON Semiconductor’s
NCP1027 Standby Power Supply for ATX Applications
and is specified in Application Note AND8241/D.
This transformer is designed for universal input, 85 –
265 Vac. It operates in continuous conduction mode
within an input voltage range of 120 Vdc to 375 Vdc and
at a 65 kHz switching frequency. Primary to secondary
isolation is 2000 Vrms.
Coilcraft can also custom engineer a transformer to
meet your specific requirements. For free evaluation
samples, contact Coilcraft or visit www.coilcraft.com.
Inductance
at 0 A1
±10% (mH)
Part
number
DA2077-AL
1.
2.
3.
4.
3.4
Leakage
inductance2
max (µH)
DCR max (Ohms)
pri
sec
aux
2.53
0.042
0.574
114
Turns ratio
pri : aux
pri : sec
1 : 0.06
1 : 0.15
Output
5 V, 2 A (sec)
12.5 V, 10 mA (aux)
Inductance is for the primary, measured at 10 kHz, 0.1 Vrms, 0 Adc
Leakage inductance tested at 100 kHz, 0.1 Vrms
Operating temperature range -40°C to +85°C.
Electrical specifications at 25°C.
1.100 max
27,94
10
5
Primary
Secondary
6
1
0.950 max
24,13
7
Auxiliary
9
0.620
15,75
0.150 ±0.030
3,81 ±0,76
6
5
0.150
3,81
Recommended
Board Layout
1
0.200
(7 places)
5,08
1.100 max
27,94
1
0.0346
0,879
10
Bottom View
0.620
15,75
0.060
1,52
Specifications subject to change without notice.
Please check our website for latest information.
© Coilcraft, Inc. 2008
Weight:
16.5 g
Terminations: Matte tin over copper
Packaged:
49 parts per tray
Document 518