EIC MBRS340T3

MBRS330T3, MBRS340T3
SURFACE MOUNT
SCHOTTKY BARRIER RECTIFIERS
PRV : 30 - 40 Volts
IO : 3.0 Amperes
SMC (DO-214AB)
0.060(1.52)
0.260(6.60)
Very Low Forward Voltage Drop
Small Compact Surface Mountable Package
Highly Stable Oxide Passivated Junction
Excellent Ability to Withstand Reverse Avalanche
Energy Transients
* Guardring for Stress Protection
0.280(7.11)
0.320(8.13)
*
*
*
*
0.305(7.75)
0.030(0.76)
FEATURES :
0.008(0.203)
0.004(0.102)
0.121(3.07)
0.115(2.92)
0.012(0.305)
0.006(0.152)
0.245(6.22)
0.220(5.59)
0.103(2.62)
0.079(2.00)
* Pb / RoHS Free
MECHANICAL DATA :
*
*
*
*
*
*
Dimensions in inches and (millimeter)
Case : SMC Molded plastic
Epoxy : UL94V-O rate flame retardant
Lead : Lead Formed for Surface Mount
Polarity : Color band denotes cathode end
Mounting position : Any
Weight : 0.21 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 °C ambient temperature unless otherwise specifie.
Single phase, half wave, 60 Hz, resistive or inductive load
For capacitive load, derate current by 20%
RATING
SYMBOL
MBRS330T3
MBRS340T3
UNIT
Maximum Repetitive Reverse Voltage
VRRM
30
40
V
Maximum Working Peak Reverse Voltage
VRWM
30
40
V
Maximum DC Blocking Voltage
VDC
30
40
V
Maximum Average Rectified Forward Current
IF(AV)
Maximum Non-repetitive Peak Surge Current (Surge applied
at rated load conditions half wave, single phase ,60 Hz)
Maximum Instantaneous Forward Voltage (Note 1)
(IF = 3.0 A, TJ = 25°C)
Maximum Instantaneous Reverse Current (Note1)
Thermal Resistance Junction to Lead
Operating Junction Temperature
3.0 @ TL = 100°C
4.0 @ TL = 90°C
IFSM
VF
80
A
A
0.50
0.525
V
IR
2.0 (T J = 25°C)
IR(H)
20 (TJ = 100°C)
RθJL
11
°C/W
TJ
- 65 to +125
°C
mA
Note: (1) Pulse Test : Pulse Width = 300μs Duty Cycle ≤ 2%
Page 1 of 2
Rev. 02 : March 30, 2005
RATING AND CHARACTERISTIC CURVES ( MBRS340T3, MBRS340T3 )
FIG.1 - CURRENT DERATING (CASE)
FIG.2 - POWER DISSIPATION
AVERAGE POWER DISSIPATION
, (W)
5
8
AVERAGE FORWARD
CURRENT, (A)
RATED VOLTAGE APPLIED
RθJC = 10.5 °C/W , TJ = 125°C
6
4
DC
2
SQUARE WAVE
0
30
40
50
60
70
80
90
100 110 120 130 140
5
TJ = 100°C
SQUARE
WAVE
4
CAPACITIVE LOAD
3
10
IPK
= 20
IAV
DC
2
1
0
CASE TEMPERATURE, ( °C)
0
1
2
3
5
4
AVERAGE FORWARD CURRENT, (A)
FIG.3 - TYPICAL FORWARD VOLTAGE
FIG.4 - TYPICAL REVERSE CURRENT
REVERSE CURRENT, (mA)
INSTANTANEOUS FORWARD
CURRENT, (A)
4
2
TC = 100°C
1
0.5
0.2
0.1
TC = 25 °C
0.05
0.03
100
TJ = 125°C
10
100°C
1.0
75°C
0.1
25°C
0.01
0
0.02
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
4
8
12
16
20
24
28
32
36
40
0.8
REVERSE VOLTAGE, (V)
INSTANTANEOUS FORWARD
VOLTAGE, (V)
FIG. 5 TYPICAL CAPACITANCE
CAPACITANCE , (pF)
500
NOTE :TYPICAL CAPACITANCE
AT 0 V = 480 pF
400
300
TJ = 25 °C
200
100
0
0
4
8
12
16
20
24
28
32
36
40
REVERSE VOLTAGE, (V)
Page 2 of 2
Rev. 02 : March 30, 2005