Switching Spark Gap CAS06XG Ordering code: B88069X1210T502 Preliminary data DC spark-over voltage 1) 2) 350 ... 900 V Impulse spark-over voltage at 100 V/µs - for 99 % of measured values - typical values of distribution < 1100 < 1000 V V < 1400 < 1300 V V Insulation resistance at 300 Vdc >1 GΩ Capacitance at 1 MHz <1 pF Service life in customer circuit Unit must meet Insulation resistance DC spark-over voltage after 250, 500, 750, and 1000 h 1000 h <1 270 ... 1000 GΩ V Arc voltage at 1 A Glow to arc transition current Glow voltage ~ 10 < 100 ~ 60 V A V Weight ~ 1.5 g Operation and storage temperature -40 ... +90 °C Climatic category (IEC 60068-1) 40/ 90/ 21 at 1 kV/µs - for 99 % of measured values - typical values of distribution Marking, red 600 YYMM O CS 600 YY MM O - Series - Nominal voltage - Year of production - Month of production - Non radioactive 1) At delivery AQL 0.65 level II, DIN ISO 2859 In ionized mode Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845 2) AB E / AB PM Issue 03, 30.04.2002 Page 1 of 2 Switching Spark Gap CAS06XG Ordering code: B88069X1210T502 Preliminary data Not to scale Dimensions in mm Non controlled document EPCOS AG 2002. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers' Association), unless otherwise agreed. AB E / AB PM Issue 03, 30.04.2002 Page 2 of 2