MICREL SY100EL91

Micrel, Inc.
TRIPLE
PECL-TO-ECL TRANSLATOR
SY100EL91
SY100EL91
DESCRIPTION
FEATURES
■ 620ps typical propagation delay
The SY100EL91 is a triple PECL-to-ECL translator. It
receives standard voltage PECL signals and translates
them to different ECL output signals.
A VBB output is provided for interfacing with single
ended PECL signals at the input. If a single ended input
is to be used, the VBB output should be connected to the
D input. The active signal would then drive the D input.
When used, the VBB output should be bypassed to ground
via a 0.01µF capacitor. The VBB output is designed to act
as the switching reference for the EL91 under single
ended input switching conditions. As a result this pin can
only source/sink up to 0.5mA of current.
To accomplish the level translation the EL91 requires
three power rails. The VCC supply should be connected
to the positive supply, and the V EE pin should be
connected to the negative power supply. The GND pins
as expected are connected to the system ground plane.
Both VEE and VCC should be bypassed to ground via
0.01µF capacitors.
Under open input conditions, the D input will be biased
at VCC/2 and the D input will be pulled to GND. This
condition will force the Q output to a LOW, ensuring
stability.
■ Fully differential design
■ Supports standard operation
■ Available in 20-pin SOIC package
PIN NAMES
Pin
M9999-031306
[email protected] or (408) 955-1690
Function
Dn
PECL Inputs
Qn
ECL Outputs
PECL_VBB
PECL Reference Voltage Output
Rev.: E
1
Amendment: /0
Issue Date: March 2006
Micrel, Inc.
SY100EL91
PACKAGE/ORDERING INFORMATION
Ordering Information(1)
D0 2
19
D0 3
ECL
PECL
PECL_V BB 4
20 VCC
ECL
PECL
VCC 1
Operating
Range
Package
Marking
Lead
Finish
SY100EL91ZC
Z20-1
Commercial
SY100EL91ZC
Sn-Pb
18
Q0
SY100EL91ZCTR(2)
Z20-1
Commercial
SY100EL91ZC
Sn-Pb
17
GND
SY100EL91ZI
Z20-1
Industrial
SY100EL91ZI
Sn-Pb
SY100EL91ZITR(2)
Z20-1
Industrial
SY100EL91ZI
Sn-Pb
SY100EL91ZG(3)
Z20-1
Industiral
SY100EL91ZG with
NiPdAu
Pb-Free bar-line indicator Pb-Free
SY100EL91ZGTR(2, 3)
Z20-1
Industrial
SY100EL91ZG with
NiPdAu
Pb-Free bar-line indicator Pb-Free
15
Q1
7
14
GND
13
Q2
12
Q2
11
VCC
ECL
D1 6
PECL
16
D2 8
Package
Type
Q0
D1 5
PECL_V BB
Part Number
Q1
Notes:
D2
9
VEE 10
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
20-Pin Wide SOIC (Z20-1)
M9999-031306
[email protected] or (408) 955-1690
2
Micrel, Inc.
SY100EL91
PECL INPUT DC ELECTRICAL CHARACTERISTICS
TA = –40°C
Symbol
TA = 0°C
TA = +25°C
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Min.
Typ.
Max.
Unit
VCC
Power Supply Voltage
4.75
—
5.25
4.75
—
5.25
4.75
—
5.25
4.75
—
5.25
V
VIH
Input HIGH Voltage(1)
3.835
—
4.120 3.835
—
4.120
3.835
—
4.120
3.835
—
4.120
V
VIL
Input LOW Voltage(1)
3.190
—
3.525 3.190
—
3.525
3.190
—
3.525
3.190
—
3.525
V
IIH
Input HIGH Current
—
—
150
—
—
150
—
—
150
—
—
150
µA
IIL
Input LOW Current Dn
Dn
0.5
–600
—
—
—
—
0.5
–600
—
—
—
—
0.5
–600
—
—
—
—
0.5
–600
—
—
—
—
µA
VBB
Output Reference(1)
3.620
—
3.740 3.620
—
3.740
3.620
—
3.740
3.620
—
3.740
V
ICC
Power Supply Current
—
—
—
11
—
6.0
11
—
—
11
mA
11
—
Typ. Max.
TA = +85°C
Note:
1. These values are for VCC = 5V. Level specifications will vary 1:1 with VCC.
ECL OUTPUT DC ELECTRICAL CHARACTERISTICS
TA = –40°C
Symbol
TA = 0°C
TA = +25°C
TA = +85°C
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
VEE
Power Supply Voltage
–4.2
—
–5.5
–4.2
—
–5.5
–4.2
—
–5.5
–4.2
—
–5.5
V
VOH
Output HIGH Voltage
–1085
—
–880 –1025
—
–880 –1025 –955
–880
–1025
—
–880
mV
VOL
Output LOW Voltage
–1830
—
–1555 –1810
—
–1620 –1810 –1705 –1620 –1810
—
–1620
mV
IEE
Power Supply Current
—
—
—
30
mA
M9999-031306
[email protected] or (408) 955-1690
28
—
—
3
28
—
22
28
—
Micrel, Inc.
SY100EL91
AC ELECTRICAL CHARACTERISTICS
PECL: VCC = +4.75V to +5.25V, ECL: VEE = -4.2V to -5.5V
TA = –40°C
Symbol
Parameter
tPD
Propagation Delay
D to Q
Diff.
S.E.
tskew
Within-Device Skew(1)
Output-to-Output
Part-to-Part (Diff.)
Duty Cycle (Diff.)
TA = 0°C
TA = +25°C
TA = +85°C
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max. Unit
520
470
620
620
720
770
520
470
620
620
720
770
520
470
620
620
720
770
550
500
650
650
750
800
ps
—
—
—
—
—
25
100
200
—
—
—
—
—
—
25
100
200
—
—
—
—
20
—
25
100
200
—
—
—
—
—
—
25
100
200
—
ps
mV
VPP
Minimum Input Swing(2)
200
—
—
200
—
—
200
—
—
200
—
—
VCMR
Common Mode Range(3)
VPP < 500mV
VPP > 500mV
1.3
1.5
—
—
VCC–0.2
—
—
VCC–0.2
—
—
VCC–0.2
1.2
1.4
—
—
VCC–0.2
VCC–0.2
1.2
1.4
VCC–0.2
VCC–0.2
1.2
1.4
320
400
580
320
400
580
320
400
580
320
400
580
tr
tf
Output Rise/Fall Times Q
(20% to 80%)
V
VCC–0.2
ps
Notes:
1. Skew is measured between outputs under identical transitions.
2. Minimum input swing for which AC parameters are guaranteed. The device has a DC gain of ~40.
3. The CMR range is referenced to the most positive side of the differential input signal. Normal operation is obtained if the HIGH level falls within the specified
range and the peak-to-peak voltage lies between VPP min. and 1V.
M9999-031306
[email protected] or (408) 955-1690
4
Micrel, Inc.
SY100EL91
20-PIN SOIC .300" WIDE (Z20-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-031306
[email protected] or (408) 955-1690
5