OMRON D3C-1210

Detection Switch
D3C
Subminiature Detection Switch
• Built-in slide mechanism provides reliable contact
• Choose from shorting or non-shorting switch timing models
• PCB mount switch with 100 milliamp capacity
• Ideal for household appliances, sound equipment, office
equipment, communications equipment, etc.
• Compact size
• RoHS Compliant
Ordering Information
Actuator
General Purpose
Pivoting Hinge lever
Low Operating Force
Non-shorting Model
Shorting Model
Non-shorting Model
Shorting Model
D3C-1210
D3C-2210
D3C-1220
D3C-2220
Model Number Legend
D3C-
2
1
0
1.
2
Switching Timing
1:
Non-shorting
(Break-before-make)
2:
2.
Maximum Oprating Force
1: 130 gf
2: 40 gf
Shorting
(Make-before-break)
Specifications
■ Characteristics
Electrical rating
100 mA, 30 VDC (resistive load)
Operating speed
1 to 500 mm/s
Operating frequency
Mechanical: 200 operations per minute, max.
Electrical: 30 operations per minute, max.
Contact resistance
50 mΩ max.
Insulation resistance
100 MΩ min. at 250 VDC
Dielectric strength
250 VAC, 50/60 Hz for 1 minute between terminals of same polarity
250 VAC, 50/60 Hz for 1 minute between current-carrying metal parts and ground
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance
Destruction: 1,000 m/s2 (approx 100G) max.
Malfunction: 300 m/s2 (approx. 30G) max.
Degree of protection
IEC IP00
Degree of protection against electric shock
Class III
Proof tracking index (PTI)
175
Ambient operating temperature
-20° to 80°C (at 60% RH max) with no icing
Ambient operating humidity
85% max. (for 5° to 35°C)
Service life
50,000 operations min. at 30 operations per minute
Weight
Approx. 0.3 g
Note: 1. Data shown are of initial value.
2. The electrical rating applies under the following test conditions:
Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min.
Detection Switch
D3C
45
Engineering Data
■ Contact Specifications
Item
■ Mounting
All D3C switches may be panel mounted using M1.6 mounting
screws with plane washers or spring washers to securely mount the
switch. Tighten the screws to a torque of 4.9 to 9.8 x 10-2 N·m.
Specification
Specification
Slide
Material
Silver plated
Minimum applicable load
(see note)
1 mA at 5 VDC
M1.6 tap
4±0.1
Note: Minimum applicable loads are indicated by N standard
reference values. This value represents the failure rate at a
60% (λ60) reliability level (JIS C5003).
5.7±0.1
■ PCB Layout (reference)
The equation λ60=0.5 x 10-6/operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%.
2.54
■ Switching Timing
Non-shorting Model
(2) (NC) FP
OP1
1.6 dia
Three, 1 dia. hole
2.54
Shorting Model
OP2
TTP
(2) (NC) FP
(1)
(3) (NO)
OP1
4.2
OP2
TTP
(1)
(3) (NO)
8
■ Contact Form
SPDT
NO COM NC
(3) (1) (2)
Dimensions
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions.
D3C-1210/-2210
D3C-1220/-2220
Operating
direction (A)
Operating direction (B)
8.7
+0.12
6.7
1.6 0 dia. hole
1-dia. hole
1R
5.7±0.15
6
4.7
4±0.15
1
0
4
8
D3C
0.8
0.3
0.9
Non-shorting Model
D3C-1210
D3C-1220
OF max.
130 gf (100 gf)
40 gf (30 gf)
RF min.
10 gf (15 gf)
3 g (5 gf)
FP max.
1.5 –0.15 dia.
2.5 2.5
Detection Switch
Model
OP FP
4.6 max.
3.5
46
5.6
4.2
1.6
Shorting Model
D3C-2210
D3C-2220
130 gf (100 gf) 40 gf (30 gf)
10 gf (15 gf)
3 g (5 gf)
4.8 mm
4.8 mm
OP1
3.5 ± 0.3 mm
3.4 ± 0.3 mm
OP2
2.5 ± 0.3 mm
2.6 ± 0.3 mm
TTP
1.3 ± 0.4 mm
1.3 ± 0.4 mm
Note: The values for operating characteristics apply for operation in the
A direction ( ). The values in parentheses indicate those for
operation in the B direction ( ).
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
■ Correct Use
■ Cautions
Mounting
Terminal Connection
Turn off the power supply before mounting or removing the switch,
wiring or performing maintenance or inspection. Failure to do so may
result in electric shock or burning.
When soldering the lead wire to the terminals, first bind the lead wire
to the terminal and then apply the 60(Sn):40(Pb) solder to the terminals. Complete soldering within 5s at a soldering iron temperature of
260°C. Soldering at a temperature exceeding 260°C, soldering for
more than 5 s, or repeated soldering will degrade the switch characteristics.
Mount the switch onto a flat surface. Mounting on an uneven surface
may cause deformation of the switch, resulting in faulty operation or
breakage in the housing.
Application of Operation Force to the Lever
Apply operation forces to the lever in its operating direction. Applying
operating force to the lever in any other directions will damage the
switch or cause malfunction.
Incorrect
Incorrect
When soldering the lead wire to the PCB terminal, pay careful attention so that the flux and solder liquid level does not exceed the PCB
level.
It is also recommended that you apply flux guard to the mounting surface of the switch.
Incorrect
Switch mounting surface
Correct
Mounting Plate
Use materials other than ABS or polycarbonate for the mounting
plate. Since grease is used within the switch, cracks may be caused
if grease from the switch comes in contact with such materials.
Using Microloads
Voltage (V)
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for
microloads and that operate in the following range;
30
0.16 mA
100 mA
24
Operating range
12
Inoperable
range
5
1mA
0
0.1
1
10
100
1,000
Current (mA)
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, then contact wear may
increase and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
Detection Switch
D3C
47
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
Global - http://www.omron.com
USA - http://www.components.omron.com
847-882-2288
Cat. No. X303-E-1
Detection Switch
11/10
D3C
Specifications subject to change without notice