RECTRON DTA123JUA

RECTRON
DTA123JUA
SEMICONDUCTOR
TECHNICAL SPECIFICATION
SOT-323 DIGITAL TRANSISTORS
TRANSISTORS(PNP)
FEATURES
* Built-in bias resistors enable the configuration of an inverter
circuit without connecting external input resistors.(see equivalent circuit).
* The bias resistors consist of thin-film resistors with complete isolation to allow negative biasing of the input.
They also have the advantage of almost completely Eliminating parasitic effects.
SOT-323
* Only the on/off conditions need to be set for operation, marking device design easy.
MECHANICAL DATA
*
*
*
*
*
0.053(1.35)
0.045(1.15)
Case: Molded plastic
Epoxy: UL 94V-O rate flame retardant
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.006 gram
0.006(0.15)
0.003(0.08)
0.043(1.10)
0.035(0.90)
REF 0.021(0.53)
0.004(0.10)
0.000(0.00)
0.096(2.45)
0.085(2.15)
0.016(0.40)
0.008(0.20)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
0.055(1.40)
0.047(1.20)
O
Ratings at 25 C ambient temperature unless otherwise specified.
(2)
(1)
(3)
1
3
0.087(2.20)
0.079(2.00)
2
(1) IN
(2) GND
(3) OUT
Dimensions in inches and (millimeters)
o
MAXIMUM RATINGES ( @ TA = 25 C unless otherwise noted )
SYMBOL
LIMITS
UNITS
Supply voltage
RATINGS
VCC
-50
V
Input voltage
VIN
-12~+5
V
IO
-100
IC(MAX)
-100
Power dissipation
Pd
200
Junction temperature
Tj
150
Storage temperature
Tstg
-55 ~150
Output current
mA
mW
o
C
o
C
ELECTRICAL CHARACTERISTICS ( @ TA = 25oC unless otherwise noted )
SYMBOL
MIN
TYP
MAX
Input voltage (VCC= -5V, IO= -100mA)
CHARACTERISTICS
VI(off)
-
-
-0.5
Input voltage (VO= -0.3V, IO= -5mA)
VI(on)
-1.1
-
-
Output voltage (IO / II= -5mA / -0.25mA)
Vo(on)
-
-0.1
-0.3
V
II
-
-
-3.6
mA
Io(off)
-
-
-0.5
mA
GI
80
-
-
-
Input resistance
R1
1.54
2.2
2.86
KW
Resistance ratio
R2 / R1
17
21
26
-
fT
-
250
-
MHz
Input current (VI= -5V)
Output current (VCC= -50V,VI= 0)
DC current gain (VO= -5V,IO= -10mA)
Transition frequency (VO= -10V, IO= -5mA, f= 100MHz)
NOTE: "Fully ROHS compliant", "100% Sn plating (Pb-free)".
UNITS
V
2006-3
RATING AND CHARACTERISTICS CURVES (DTA123JUA)
100
20
10
5
O
Ta= -40 C
O
25 C
O
100 C
2
1
VCC = 5V
5m
IO, OUTPUT CURRENT, (A)
VI(on), INPUT VOLTAGE, (V)
10m
VO = 0.3V
50
500m
2m
1m
500m
200m
O
Ta= 100 C
O
25 C
O
-40 C
100m
50m
20m
10m
5m
200m
2m
100m
100m 200m 500m
1m
2m
5m
10m 20m
1m
50m 100m
0
0.5
IO, OUTPUT CURRENT, (A)
Gi, DC CURRENT GAIN
500
200
100
Figure1 Input voltage vs. output current
(ON Characteristics)
2.0
O
Ta= 100 C
O
25 C
O
-40 C
20
10
5
2
1m
2m
5m
10m 20m
3.0
IO / II= 20
500m
100m 200m 500m
2.5
Figure2 Output current vs. input voltage
(OFF Characteristics)
1
VO = 5V
50
1
1.5
VI(off), INPUT VOLTAGE, (V)
VO(on), OUTPUT VOLTAGE, (V)
1K
1.0
200m
O
Ta= 100 C
O
25 C
O
-40 C
100m
50m
20m
10m
5m
2m
1m
100m 200m 500m
50m 100m
IO, OUTPUT CURRENT, (A)
1m
2m
5m
10m 20m
50m 100m
IO, OUTPUT CURRENT, (A)
Figure3 DC current gain vs. output current
IN
Figure4 Output voltage vs. output current
OUT
R1
R2
GND(+)
IN
OUT
GND(+)
Figure5 Equivalent circuit
RECTRON
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
RECTRON