Monolithic crystal filter MQF10.0-0760/01 (preliminary specification) Application • 2 pol filter • i.f.- filter • use in mobile and stationary transceivers Characteristics Pass band Pin connections: Unit Value MHz dB kHz dB dB dB dB 10.0 < 1.0 ±> 3.8 < 1.0 > 30 > 40 > 14 Terminating impedance Z R1||C1 R2||C2 Ohm/pF Ohm/pF 3900 || 2 3900 || 2 Operating temp. range °C -25... +55 Limiting values Nominal frequency Insertion loss Pass band at 3.0dB Ripple in pass band Stop band attenuation Alternate attenuation Spurious responses: fo fo ± 2 kHz fo ± 40 kHz fo ± 60...600 kHz MQF10.0-0760/01 Stop band 1 2 3 4 Input Ground-Input Output Ground-Output TELE FILTER Zweigniederlassung der DOVER Germany GMBH 28.07.03 Potsdamer Str. 18 D- 14513 Teltow ! (+49)03328-4784-10 ; Fax (+49)03328-4784-30 http:\\www.vectron.com