Document 133 50/60Hz Current Sensor – CS60-010 This Coilcraft current sensor is intended for measuring current from 1 to 10 amps rms. The sensor functions as the encapsulated secondary of a current transformer, while the conductor carrying the current to be measured serves as the “one turn primary.” Sensitivity may be enhanced by increasing primary turns. Minimum wall thickness of the hole is 0.5 mm to meet IEC 380 and other requirements when used with an insulated conductor. Applications include sensing branch circuit overload and detecting load drop or shutdown. Coilcraft Designer’s Kit P403 contains two samples of this sensor and 15 samples of nine different high frequency current sensors. To order, contact Coilcraft or visit http://order.coilcraft.com. Part number Sensed current Irms Vout tolerance CS60-010L 1–10 A rms ±10% Typical Response 100 (For sensed current above 10 Arms, see CS60 data sheet) 90 1. Operating temperature range −40°C to +85°C. 2. Electrical specifications at 25°C. 80 0.75 max 19,05 0.550 max 13,97 Date code 0.125 min 3,175 0.80 max 20,30 VOUT (mVolts p-p) 70 60 10 0-0 6 CS 50 40 30 20 0.033 ±0.002 0,84 ±0,05 0.34 max 8,64 0.45 max 11,43 3 0.125 max 3,175 10 1 2 3 5 4 3 8 7 9 10 1 0.50 ±0.015 12,7 ±0,38 Typical Application Irms Weight: 5.8 g Terminations: Tin-silver over copper 1+ 3− 50⏲ Specifications subject to change without notice. Please check our website for latest information. © Coilcraft, Inc. 2006 6 Current (A rms) Vout rms Document 133 Revised 02/01/05