COILCRAFT CS60-010L

Document 133
50/60Hz Current Sensor – CS60-010
This Coilcraft current sensor is intended for measuring
current from 1 to 10 amps rms. The sensor functions as
the encapsulated secondary of a current transformer,
while the conductor carrying the current to be measured serves as the “one turn primary.” Sensitivity may
be enhanced by increasing primary turns.
Minimum wall thickness of the hole is 0.5 mm to meet
IEC 380 and other requirements when used with an
insulated conductor.
Applications include sensing branch circuit overload
and detecting load drop or shutdown.
Coilcraft Designer’s Kit P403 contains two samples of
this sensor and 15 samples of nine different high frequency current sensors. To order, contact Coilcraft or
visit http://order.coilcraft.com.
Part
number
Sensed
current Irms
Vout
tolerance
CS60-010L
1–10 A rms
±10%
Typical Response
100
(For sensed current above 10 Arms, see CS60 data sheet)
90
1. Operating temperature range −40°C to +85°C.
2. Electrical specifications at 25°C.
80
0.75
max
19,05
0.550
max
13,97
Date code
0.125
min
3,175
0.80
max
20,30
VOUT (mVolts p-p)
70
60
10
0-0
6
CS
50
40
30
20
0.033 ±0.002
0,84 ±0,05
0.34 max
8,64
0.45
max
11,43
3
0.125
max
3,175
10
1
2
3
5
4
3
8
7
9
10
1
0.50 ±0.015
12,7 ±0,38
Typical Application
Irms
Weight:
5.8 g
Terminations: Tin-silver over copper
1+
3−
50⏲
Specifications subject to change without notice.
Please check our website for latest information.
© Coilcraft, Inc. 2006
6
Current (A rms)
Vout rms
Document 133