EIC RK43

RK43 - RK44
SCHOTTKY BARRIER
RECTIFIER DIODES
PRV : 30 - 40 Volts
IO : 3.0 Amperes
DO-201AD
FEATURES :
*
*
*
*
*
*
*
High current capability
High surge current capability
High reliability
High efficiency
Low power loss
Low cost
Low forward voltage drop
1.00 (25.4)
MIN.
0.21 (5.33)
0.19 (4.82)
0.375 (9.52)
0.285 (7.24)
1.00 (25.4)
MIN.
0.052 (1.32)
0.048 (1.22)
MECHANICAL DATA :
* Case : DO-201AD Molded plastic
* Epoxy : UL94V-O rate flame retardant
* Lead : Axial lead solderable per MIL-STD-202,
Method 208 guaranteed
* Polarity : Color band denotes cathode end
* Mounting position : Any
* Weight : 1.1 grams
Dimensions in inches and ( millimeters )
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 °C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
RATING
SYMBOL
RK43
RK44
UNIT
Maximum Peak Reverse Voltage
VRM
30
40
V
Maximum Peak Reverse Surge Voltage
VRSM
35
45
V
Maximum Average Forward Current TL = 109 °C
IF(AV)
3.0
A
IFSM
80
A
VF
0.55
V
mA
Maximum Peak Forward Surge Current,
8.3ms single half sine wave Superimposed
on rated load (JEDEC Method)
Maximum Forward Voltage at IF = 3.0 A
Maximum Reverse Current at VRM
Ta = 25 °C
IR
5.0
Maximum Reverse Current at VRM
Ta = 100 °C
IR(H)
50
mA
Junction Temperature Range
TJ
- 40 to + 150
°C
Storage Temperature Range
TSTG
- 40 to + 150
°C
Note :
(1) Pulse Test : Pulse Width = 300 µs, Duty Cycle = 2%.
Page 1 of 2
Rev. 02 : September 7, 2005
RATING AND CHARACTERISTIC CURVES ( RK43 - RK44 )
FIG.2 - MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
100
5
PEAK FORWARD SURGE
CURRENT, AMPERES
AVERAGE FORWARD OUTPUT
CURRENT, AMPERES
FIG.1 - DERATING CURVE FOR OUTPUT
RECTIFIED CURRENT
4
3
2
1
0
80
90
100
110
120
130
140
80
60
40
20
0
150
1
2
LEAD TEMPERATURE, ( °C)
10
FORWARD CURRENT, AMPERES
6
10
20
40
60
100
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
REVERSE CURRENT, MILLIAMPERES
FIG.3 - TYPICAL FORWARD CHARACTERISTICS
1.0
0.1
Ta = 25 °C
0.01
4
NUMBER OF CYCLES AT 50Hz
10
TJ = 100 °C
1.0
0.1
TJ = 25 °C
0.01
0
20
40
60
80
100
120
140
PERCENT OF RATED REVERSE
VOLTAGE, (%)
0.001
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
FORWARD VOLTAGE, VOLTS
Page 2 of 2
Rev. 02 : September 7, 2005