EPCOS B44066M6100E230

Film capacitors – Capacitors for Power Factor Correction
Key components
Multi-measuring interface MMI6000 for BR6000 controller
Series/Type:
MMI6000
Ordering code: B44066M6…E230
Date:
Version:
September 2007
1
Content of inside pages of data sheet. Data will be automatically entered into frontpage
headlines, headers and footers. Please fill in the table and then change the colour to “White”.
This ensures that the table disappears for the customer pdf.
Identification/Classification 1:
(header 1)
Film capacitors – Capacitors for Power Factor Correction
Identification/Classification 2:
(header 2)
Key components
Ordering code:
B44066M6…E230
Series/Type:
MMI6000
Preliminary data (optional):
(if necessary)
Preliminary
Department:
FK PC PM PFC
Date:
September 2007
© EPCOS AG 2007. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Film capacitors – Capacitors for Power Factor Correction
Key components
B44066M6…E230
MMI6000
Characteristics
„ Measuring device for electrical (real current) measurement
„ Additional protection for PFC systems
„ Two in one:
• Accessory for PF-controller BR6000 series
• Stand-alone measuring device
„ Illuminated graphical display
„ Small dimensions
Technical data and specifications
Types/Output
MMI6000-R (1 standard relay)
MMI6000-T (1 optocoupler)
Interface
RS485
Display
Graphical, 2 × 16 characters
Supply and measurement voltage
230 V, 50/60 Hz
Power consumption
< 4 VA
Measurement current
X/5 A and X/1 A
Output capacity
Standard relay: 250 V AC, 1000 W
Optocoupler:
60 V DC, 150 mA
Measuring temperature range
0 … 100 °C
Ambient temperature range
–10 ... +55 °C
Housing
Switchboard installation housing, DIN 43 700
Dimensions
100 × 100 × 50 mm
Weight
0.5 kg
Protection category to DIN 40 050
Front side: IP54
Rear side: IP20
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
September 2007
Page 2 of 5
Film capacitors – Capacitors for Power Factor Correction
Key components
Operation modes
B44066M6…E230
MMI6000
Coupling MMI6000 – BR6000
Coupling MMI6000 – BR6000T
DYNA-I-TRIGGER
MMI – MODBUS RTU
MMI – ASCII OUT
Measurement categories
Voltage, current
Power factor
Active power
Reactive power
Apparent power
Frequency
Temperature
Energy
Languages
German and English
Ordering Codes
MMI6000-R
B44066M6000E230
MMI6000-T
B44066M6100E230
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
September 2007
Page 3 of 5
Film capacitors – Capacitors for Power Factor Correction
Key components
B44066M6…E230
MMI6000
Cautions and warnings
General
• The MMI 6000 may only be used for the purpose it has been designed for.
• The device has to be projected in such a way that in case of any failure no uncontrolled high
current and voltages may occur.
• The device in operation has to be protected against moisture and dust, sufficient cooling has to be
assured.
• Please note that the device is under high tension during operation.
• The MMI 6000 may only be used indoor. It is not suitable for outdoor applications.
• Voltages above the permitted voltage range may damage the device.
Attention
FAILURE TO FOLLOW CAUTIONS MAY RESULT, WORST CASE, IN PREMATURE FAILURES OR
PHYSICAL INJURY.
Note
For detailed information about PFC capacitors and cautions, refer to the latest version of the EPCOS
PFC Product Profile.
U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual
version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case,
bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications.
Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to
approve our product specifications or request our approval for your specification before ordering.
FK PC PM PFC
Please read Cautions and warnings and
Important notes at the end of this document.
September 2007
Page 4 of 5
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components
or failure before the end of their usual service life cannot be completely ruled out in the
current state of the art, even if they are operated as specified. In customer applications
requiring a very high level of operational safety and especially in customer applications in which
the malfunction or failure of a passive electronic component could endanger human life or health
(e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of
suitable design of the customer application or other action taken by the customer (e.g. installation
of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the
event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, MiniBlue, MKK, MLSC, MotorCap,
PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID,
SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or
pending in Europe and in other countries. Further information will be found on the Internet at
www.epcos.com/trademarks.
FK PC PM PFC
September 2007
Page 5 of 5