Current-compensated ring core triple chokes
Rated voltage 440/250 V AC
Rated current 50 A to 200 A
Rated inductance 0.12 mH to 1.3 mH
Construction
■
■
■
■
■
■
Current-compensated ring core triple choke
Ferrite core
Aluminum case
Fixing by means of base plate
Polyurethane potting (UL 94 V-0)
Sector winding
Features
■ High power
■ Design complies with EN 60938-2 (VDE 0565-2)
■ RoHS-compatible
Applications
■
■
■
■
Suppression of common-mode interferences
Switch-mode power supplies for converters, USV
Power supplies, medical equipment
Track vehicles, chargers
Terminals
■ Litz wires
■ Stud terminals
Marking
Manufacturer, ordering code, rated current, rated inductance,
rated voltage, climatic category, date of manufacture (MM.YY)
Delivery mode
Cardboard box
Please read Cautions and warnings and
Important notes at the end of this document.
2
10/08
Power line chokes
B82745C
Current-compensated ring core triple chokes
Dimensional drawings and electrical circuits
B82745C*A007
142
130±0.2
ø4.8
1
1’
2
2’
3
3
3’
IND0275-W
2
122
90
60±0.2
3’
2’
1’
1
10±2
122
67
400±10
IND0276-9
B82745C*A010, A013
h1
a
1
1’
2
2’
3
3’
123
IND0275-W
2
ø5.8
155±0.2 x 80±0.2
2’
2
3
3 x 32±0.3
128±0.5
145±0.5
1’
1
3’
(206)
174±0.5
145±0.5
IND0277-H
Type
a
h1
B82745C0002A010
B82745C0002A013
M10
M8
30 mm
20 mm
Tolerances to ISO 2768-C unless otherwise noted.
Please read Cautions and warnings and
Important notes at the end of this document.
3
Dimensions in mm
10/08
Power line chokes
B82745C
Current-compensated ring core triple chokes
Technical data and measuring conditions
Rated voltage VR
440/250 V AC (50/60 Hz)
Test voltage Vtest
2500 V AC, 2 s (line/line)
2500 V AC, 2 s (line/case)
Rated temperature TR
60 °C
Rated current IR
Referred to 50 Hz and rated temperature
Rated inductance LR
Measured with Agilent 4284A at 0.1 mA, 20 °C
Measuring frequency: LR ≤ 1 mH = 100 kHz
LR > 1 mH = 10 kHz
Inductance is specified per winding.
Inductance tolerance
±30% at 20 °C
Inductance decrease ΔL/L0
< 20% at DC magnetic bias with IR, 20 °C
DC resistance Rtyp
Measured at 20 °C, typical values, specified per winding
Climatic category
40/125/56 (to IEC 60068-1)
Storage conditions (packaged)
–25 °C … +40 °C, ≤ 75% RH
Characteristics and ordering codes
IR
LR
Rtyp
Terminal
Ordering code
mΩ
Weight
kg
A
mH
50
1.3
3.75
1.7
Litz wire 11.5 mm 2
B82745C0005A007
100
0.33
0.65
6.0
Stud terminal M 10
B82745C0002A010
200
0.12
0.28
6.3
Stud terminal M 8
B82745C0002A013
Please read Cautions and warnings and
Important notes at the end of this document.
4
10/08
Power line chokes
B82745C
Current-compensated ring core triple chokes
Impedance |Z| versus frequency f
measured with windings in parallel at 20 °C,
typical values
Current derating Iop/IR
versus ambient temperature TA
IND0372-K-E
1.4
I op
I R 1.2
1.0
TR = 60 ˚C
0.8
0.6
0.4
0.2
0
0
20
40
60
80
100
˚C 140
TA
5
10/08
Cautions and warnings
■ Please note the recommendations in our Inductors data book (latest edition) and in the data
sheets.
– Particular attention should be paid to the derating curves given there.
– The soldering conditions should also be observed. Temperatures quoted in relation to wave
soldering refer to the pin, not the housing.
■ If the components are to be washed varnished it is necessary to check whether the washing
varnish agent that is used has a negative effect on the wire insulation, any plastics that are used,
or on glued joints. In particular, it is possible for washing varnish agent residues to have a
negative effect in the long-term on wire insulation.
■ The following points must be observed if the components are potted in customer applications:
– Many potting materials shrink as they harden. They therefore exert a pressure on the plastic
housing or core. This pressure can have a deleterious effect on electrical properties, and in
extreme cases can damage the core or plastic housing mechanically.
– It is necessary to check whether the potting material used attacks or destroys the wire
insulation, plastics or glue.
– The effect of the potting material can change the high-frequency behaviour of the components.
■ Ferrites are sensitive to direct impact. This can cause the core material to flake, or lead to
breakage of the core.
■ Even for customer-specific products, conclusive validation of the component in the circuit can
only be carried out by the customer.
Please read Cautions and warnings and
Important notes at the end of this document.
6
10/08
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with
them than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very
high level of operational safety and especially in customer applications in which the malfunction
or failure of an electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of
the customer application or other action taken by the customer (e.g. installation of protective
circuitry or redundancy) that no injury or damage is sustained by third parties in the event of
malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products.
Consequently, we cannot guarantee that all products named in this publication will always be
available.
The aforementioned does not apply in the case of individual agreements deviating from the
foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version
of the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP, MiniBlue,
MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT, SIFI, SIKOREL,
SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will be
found on the Internet at www.epcos.com/trademarks.
7
03/09