This document was generated on 05/18/2010 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION Part Number: Status: 1120115028 Active Description: Direct-Link™ PCU-DPIO Profibus-DP Master/Slave 12 Mbps, PCI Express 1x Documents: Drawing (PDF) RoHS Certificate of Compliance (PDF) General Product Family Series Approvals Comments Network Interface 112011 CE Profibus DP-V0 (Master & Slave). . PROFIBUS DP-V1 (Master) Profibus: 9.6 kbps to 12 Mbps N/A N/A Direct-Link® Profibus* DP Profibus* Card Communication Speed MAC Address Mounting Style Product Name Protocol Type Physical Channels Interface Network Connection Type Packaging Type Processor Temperature Range - Operating 1 Profibus* D-Sub Female (9 pin) Individual Carton AMD SC520 0°C to +65°C EU RoHS China RoHS ELV and RoHS Compliant REACH SVHC Not Reviewed Halogen-Free Status Not Reviewed Need more information on product environmental compliance? Email [email protected] For a multiple part number RoHS Certificate of Compliance, click here Please visit the Contact Us section for any non-product compliance questions. Search Parts in this Series 112011Series Electrical Current - Maximum Input EMC Supply Voltage 5.5W EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, IEC 61000-6-2 3.3V Material Info Old Part Number DRL-DPM-PCIE Reference - Drawing Numbers Sales Drawing SD-112011-0008 This document was generated on 05/18/2010 PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION BradCommunications™ Direct-Link™ Profibus-DP network interface cards allow deterministic I/O data acquisition for PC-based control applications. 27 Jan. 10 DW200591 Features Direct-Link™ Profibus-DP Data acquisition for real time Control applications • NEW! RoHS compliant • Connect PC-Based Control applications directly to I/O devices PCI-Universal • Protocols supported: Profibus-DP V0 Master/Slave Class-1 & 2 Profibus-DP V1 Master Class-1 & 2 (for PCI-Universal card only) Profibus-DP Slave passive PCI Express • Available in various card form factor: PC/104, PCI-Universal and CompactPCI 3U • 1 Serial or Ethernet port for remote configuration and diagnostic • Automatic devices detection on the network • Embedded Communication on the card for powerful data throughput • Configuration stored in the device (Flash memory), with auto boot mode OS supported Standard package • Windows 32-bit (XP SP1/ 2000 SP4 / NT SP6, 2003 Server), Ardence RTX Free Download • Windows XP Embedded, QNX, VxWorks, Linux, Phar Lap ETS, DOS Woodhead is a member of PTO (PROFIBUS Trade Organization), PNO (PROFIBUS Nutzerorganisation e. V.) and France Profibus. PC/104 CompactPCI Overview BradCommunications™ Direct-Link™ is a low range of automation components for industrial communication. It includes a variety of products such as diagnostic tools, intelligent connectors, tunneling gateways, fieldbuses network interface cards, and software drivers for industrial networks. Simple as they are affordable, BradCommunications™ Direct-Link™ products allow you to acquire the equipment to develop your architectures and industrial applications at a lower cost. Direct-Link™ products are characterized by their simple use and fast implementation; they are modular and scalable. Moreover, they are designed to be easily embedded into computerized systems and are available in a wide selection of form factors. Powerful Network Interface card Particularly, the BradCommunications™ Direct-Link™ Profibus-DP interface cards are equipped with 1 Profibus port handling Profibus protocol in Master and/or Slave modes up to 12 Mbps. A smart A.D.M (Automatic Dual port ram Mapping) mechanism avoids the I/O tags configuration in the Dual Port RAM of the card. More than a simple I/O acquisition card, the Direct-Link™ interface cards provide the applications with additional information such as: device status and diagnostics, process data read/write monitoring, communication tools for troubleshooting, hardware and software Watchdog, etc.. The communication layers are completely embedded on the cards, allowing easy and fast communication with field devices resulting in remarkable application performance. Product package includes: Graphical console for configuration and diagnostic tools Data servers (Multi-protocol OPC DA 3.0 & 2.05, ActiveX, DAServer, FastDDE/SuiteLink) I/O libraries for Windows (DLL) and Ardence's hard real time extensions (RTX) Static library for non-windows OS Drivers for soft-logic packages Technical data Direct-Link™ PCU-DPIO Direct-Link™ PCIE-DPIO Key Benefits • Fast data exchange (on-board processor take off the load of the host CPU) • Speed up to 12 Mbps • Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS • DP-V0 Master Class 1 & 2/Slave simultaneously • DP-V1 Master Class 1 & 2 Hardware Unit PCI-Universal 3.3/5V, PCI-X compatible PCI Express 1x Processor AMD SC520, 133 Mhz AMD SC520, 133 Mhz Profibus ASIC UART High Speed UART High Speed Memory Flash Memory Interruption 16 Mbytes SDRAM 16 Mbytes SDRAM 4 Mbytes 4 Mbytes Hardware Plug&Play Hardware Plug&Play DPRAM Address Hardware Plug&Play (32 Kbytes) Hardware Plug&Play (32 Kbytes) Discrete Input 1 x Opto-coupled discrete input, Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz) 1 x "WatchDog" output contact free from potential (floating) (24 V DC, 0.25 A) 1 x Opto-coupled discrete input, Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz) 1 x "WatchDog" output contact free from potential (floating) (24 V DC, 0.25 A) Dimensions (LxW) 168mm x 107mm (6.61" x 4.21") 168mm x 107mm (6.61" x 4.21") Consumption 5.5W (max. 1.2A) 5.5W (max. 1.2A) Operating T° 0ºC (32ºF) up to +65°C (149°F) 0ºC (32ºF) up to +65°C (149°F) Storage T° -40º C (-40°F) up to +85ºC (185º F) EN55022 Class B, EN61000-6-2, EN61000-3-2, EN61000-3-3 YES -40º C (-40°F) up to +85ºC (185º F) EN55022 Class B, EN61000-6-2, EN61000-3-2, EN61000-3-3 YES Port type 1 Profibus port (EN 50170) 1 Profibus port (EN 50170) Connector Profibus D-Sub, 9 pin, female Profibus D-Sub, 9 pin, female LED Indicator 2 bicolor Leds: bus fault and communication status 2 bicolor Leds: bus fault and communication status Electrical Interface RS485 optical insulation (500 V) RS485 optical insulation (500 V) Baud Rate 9.6 kbps ↔ 12 Mbps 9.6 kbps ↔ 12 Mbps Discrete Output EMC Compliance RoHS Compliance Communication port Port for remote configuration and diagnostic Port Type Ethernet port Ethernet port Connector type RJ45 RJ45 LED indicators 4 Leds - TX/RX/Link/100 Mbps 4 Leds - TX/RX/Link/100 Mbps Electrical interface Ethernet Ethernet Speed 10/100 Mbps 10/100 Mbps Technical data Direct-Link™ PC104-DPIO Direct-Link™ CPCI-DPIO Key Benefits • Fast data exchange (on-board processor take off the load of the host CPU) • Speed up to 12 Mbps • Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS • DP-V0 Master Class 1 & 2/ Slave simultaneously Hardware Unit PC/104 bus CompactPCI bus, 5V Processor AMD SC520, 100 Mhz AMD SC520, 133 Mhz Profibus ASIC ASPC2 ASPC2 Memory 8 Mbytes SDRAM 8 Mbytes SDRAM Flash Memory 512 Kbytes 512 kbytes Interruption 2, 3, 4, 5, 6, 7, 10, 11, 12, 14, 15 Hardware Plug&Play DPRAM Address From C8000 to DE000 (8 Kbytes used per card) Hardware Plug&Play (16 Kbytes) Discrete Input 1 x Opto-coupled discrete input, Voltage -> +10 to +30V DC or 24V AC (50-60 Hz) 1 x Opto-coupled discrete input, Voltage -> +10 to +30V DC or 24V AC (50-60 Hz) Discrete Output 1 x "WatchDog" output contact free from potential (floating) (24 V DC, 0.25 A) 1 x "WatchDog" output contact free from potential (floating) (24 V DC, 0.25 A) Dimensions (LxW) 95mm x 90mm (3.74" x 3.54") 100mm x 160mm (3.93" x 6.29") - 3U Consumption 5.5W (max. 1.2A) 5,5W (max. 1.2A) Operating T° 0ºC (32°F) up to +65ºC (149ºF) 0º C (32º F) ↔ +65º C (149º F) Storage T° -40º C (-40°F) up to +85ºC (185º F) -40º C (-40°F) up to +85ºC (185º F) EMC Compliance EN55022 Class B, EN61000-6-2, EN61000-3-2, EN61000-3-3 EN55022 Class B, EN61000-6-2, EN61000-3-2, EN61000-3-3 RoHS Compliance NO YES 1 Profibus port (EN 50170) LED Indicator 1 Profibus port (EN 50170) In standard: HE13 (2 x 5 pins) or in option: 9-pin, SubD, female 2 bicolor Leds: bus fault and communication status Electrical Interface RS485 optical insulation (500 V) RS485 optical insulation (500 V) Baud Rate 9.6 kbps ↔ 12 Mbps 9.6 kbps ↔ 12 Mbps Communication port Port type Connector Profibus D-Sub, 9 pin, female 2 bicolor Leds: bus fault and communication status Port for remote configuration and diagnostic Port Type Asynchronous Serial port Asynchronous Serial port Connector type HE13 (2 x 5 pins) 9-pin, Sub-D, male LED indicators - 2 Leds - TX/RX Electrical interface RS232 – 2 signals RS232 – 2 signals Speed 9600, 38400, 115200 bps 9600, 38400, 115200 bps Direct-Link™ Profibus-DP Protocol Specifications All BradCommunications™ Direct-Link™ networks interface cards for Profibus-DP support following protocols: DP-V0 Master/Scanner Class-1 & -2 and Slave modes simultaneously DP-V0 Slave passive mode only DP-V1 Master Class-1 & -2 (for PCU card) DP Master features Access Modes DPV0 Master/Scanner Class-1 for optimized exchange of input/output data with the slaves (Data_Exchange). DP-V0 Master Class-2 for: Slave diagnostics Reading inputs/outputs of a slave Reading configuration data Changing the slave address. DP-V1 Master Class-1 & -2: Read Data Block Class 1 Write Data Block Class 1 Read Data Block Class 2 Write Data Block Class 2 Abort Data Block Comm Class 2 Multi-master mode Watchdog control Input/Output Data Yes (able to share the bus with other DP masters connected on the network) Yes, enables the master to switch into error if no data has been exchanged during this period (Bus Fault) Memory of I/O data image: o PC/104: up to 2Kbytes o PCI-Universal: up to 8Kbytes o PCI Express: up to 8Kbytes o CompactPCI: up to 4Kbytes Manage up to 244 data bytes per slave Automatic organization of I/O data in the DPRAM memory Max. DP Slave Connect up to 126 slaves Data consistency Yes (i.e. user gets the data up to 122 bytes of a slave from one and the same DP cycle) Data format Direct access to variable types (bit, byte, word, double word) Local DP slave Run simultaneously with Master modes. Offers data exchange with another master on the network. The size of the input and output data is user-definable, and all exchange combinations are possible (from 0 to 244 bytes). The slave can ensure data consistency up to 122 bytes. (see DP-Slave features below for details). DP Slave passive features Access Mode DP-V0 Slave passive (no management of Profibus token) Input memory size Configurable from 0 to 244 bytes Output memory size Configurable from 0 to 244 bytes Slave address Configurable from 0 to 126 by software configuration GSD files Provided on the CD-Rom Data Format Configurable Intel or Motorola Address Assignment Master (Set_Slave_Address) Not supported Extended Diagnostic Not supported Direct-Link™ Profibus-DP Software tools The core of BradCommunications™ Direct-Link™ PC Network Interface cards lies in effective software tools enabling fast integration of industrial communication into your applications. More precisely, Direct-Link™ package includes configuration software called Console used to set up card, network and equipments connected to the fieldbus. The Console performs dynamic network diagnostic and allows defining access items to the input/output data used by the software interfaces (OPC server, ActiveX Control, DAServer, DDE/SuiteLink server). - Device Configuration - The console is common to all fieldbuses offer as EtherNet/IP, PROFINET IO, Modbus TCP, DeviceNet and CANopen. Other great features managed by the Console: - Powerful Graphical User Interface - Automatic detection of cards plugged into the host computer - User configuration manager: create, backup and restore many user configurations - Manual or Automatic device configuration - Profibus scanner (automatic configuration by detection of slaves connected) - GSD library. Add/Remove GSD file - Diagnostic monitor; scan devices connected on the bus, able to change DP slave address - Card Status indicator: allows you to quickly find the initialization status of each card - Profibus Network Monitoring - - Troubleshooting & Testing tool – Ordering Information Part Number SAP DRL-DPM-PCU 1120110008 DRL-DPM-PCIE 1120115028 DRL-DPM-CPI 1120185004 BradCommunications™ Direct-Link™ CPCI-DPIO ProfibusDP Master/Slave 12 Mbps, CompactPCI bus 3U DRL-DPM-104 1120130003 BradCommunications™ Direct-Link™ PC104-DPIO Profibus-DP Master/Slave 12 Mbps, PC/104 bus - Browsing of OPC Server - Product Description BradCommunications™ Direct-Link™ PCU-DPIO ProfibusDP Master/Slave 12 Mbps, PCI-Universal bus, 3.3/5V BradCommunications™ Direct-Link™ PCU-DPIO ProfibusDP Master/Slave 12 Mbps, PCI Express 1x To contact us: www.woodhead.com North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136 Europe: France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 – United Kingdom: +44 1495 356300 Asia: Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717 Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950 Brad is a registered trademark and BradCommunications and applicom are trademarks of Molex Incorporated. © 2008 Molex