MOLEX DRL-DPM-PCIE

This document was generated on 05/18/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
Part Number:
Status:
1120115028
Active
Description:
Direct-Link™ PCU-DPIO Profibus-DP Master/Slave 12 Mbps, PCI Express 1x
Documents:
Drawing (PDF)
RoHS Certificate of Compliance (PDF)
General
Product Family
Series
Approvals
Comments
Network Interface
112011
CE
Profibus DP-V0 (Master & Slave). . PROFIBUS DP-V1
(Master)
Profibus: 9.6 kbps to 12 Mbps
N/A
N/A
Direct-Link®
Profibus* DP
Profibus* Card
Communication Speed
MAC Address
Mounting Style
Product Name
Protocol
Type
Physical
Channels
Interface
Network Connection Type
Packaging Type
Processor
Temperature Range - Operating
1
Profibus*
D-Sub Female (9 pin)
Individual Carton
AMD SC520
0°C to +65°C
EU RoHS
China RoHS
ELV and RoHS
Compliant
REACH SVHC
Not Reviewed
Halogen-Free
Status
Not Reviewed
Need more information on product
environmental compliance?
Email [email protected]
For a multiple part number RoHS Certificate of
Compliance, click here
Please visit the Contact Us section for any
non-product compliance questions.
Search Parts in this Series
112011Series
Electrical
Current - Maximum Input
EMC
Supply Voltage
5.5W
EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, IEC
61000-6-2
3.3V
Material Info
Old Part Number
DRL-DPM-PCIE
Reference - Drawing Numbers
Sales Drawing
SD-112011-0008
This document was generated on 05/18/2010
PLEASE CHECK WWW.MOLEX.COM FOR LATEST PART INFORMATION
BradCommunications™ Direct-Link™ Profibus-DP network
interface cards allow deterministic I/O data acquisition
for PC-based control applications.
27 Jan. 10
DW200591
Features
Direct-Link™ Profibus-DP
Data acquisition for real time Control applications
• NEW! RoHS compliant
• Connect PC-Based Control
applications directly to I/O
devices
PCI-Universal
• Protocols supported:
ƒ Profibus-DP V0 Master/Slave
Class-1 & 2
ƒ Profibus-DP V1 Master Class-1 &
2 (for PCI-Universal card only)
ƒ Profibus-DP Slave passive
PCI Express
• Available in various card form
factor: PC/104, PCI-Universal and
CompactPCI 3U
• 1 Serial or Ethernet port for
remote configuration
and diagnostic
• Automatic devices detection on
the network
• Embedded Communication on
the card for powerful data
throughput
•
Configuration stored in the device
(Flash memory), with auto boot
mode
OS supported
Standard package
•
Windows 32-bit (XP SP1/ 2000 SP4 /
NT SP6, 2003 Server), Ardence
RTX
Free Download
•
Windows XP Embedded, QNX,
VxWorks, Linux, Phar Lap ETS,
DOS
Woodhead is a member of PTO (PROFIBUS
Trade Organization), PNO (PROFIBUS
Nutzerorganisation e. V.) and France
Profibus.
PC/104
CompactPCI
Overview
BradCommunications™ Direct-Link™ is a low range of automation components for
industrial communication. It includes a variety of products such as diagnostic tools,
intelligent connectors, tunneling gateways, fieldbuses network interface cards, and
software drivers for industrial networks.
Simple as they are affordable, BradCommunications™ Direct-Link™ products allow
you to acquire the equipment to develop your architectures and industrial
applications at a lower cost.
Direct-Link™ products are characterized by their simple use and fast
implementation; they are modular and scalable. Moreover, they are designed to be
easily embedded into computerized systems and are available in a wide selection
of form factors.
Powerful Network Interface card
Particularly, the BradCommunications™ Direct-Link™ Profibus-DP interface
cards are equipped with 1 Profibus port handling Profibus protocol in Master
and/or Slave modes up to 12 Mbps.
A smart A.D.M (Automatic Dual port ram Mapping) mechanism avoids the I/O tags
configuration in the Dual Port RAM of the card. More than a simple I/O acquisition
card, the Direct-Link™ interface cards provide the applications with additional
information such as: device status and diagnostics, process data read/write
monitoring, communication tools for troubleshooting, hardware and software
Watchdog, etc..
The communication layers are completely embedded on the cards, allowing easy
and fast communication with field devices resulting in remarkable application
performance.
Product package includes:
ƒ
Graphical console for configuration and diagnostic tools
ƒ
Data servers (Multi-protocol OPC DA 3.0 & 2.05, ActiveX, DAServer,
FastDDE/SuiteLink)
ƒ
I/O libraries for Windows (DLL) and Ardence's hard real time extensions
(RTX)
ƒ
Static library for non-windows OS
ƒ
Drivers for soft-logic packages
Technical data
Direct-Link™
PCU-DPIO
Direct-Link™
PCIE-DPIO
Key Benefits
• Fast data exchange (on-board processor take off the load of the host CPU)
• Speed up to 12 Mbps
• Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS
• DP-V0 Master Class 1 & 2/Slave simultaneously
• DP-V1 Master Class 1 & 2
Hardware
Unit
PCI-Universal 3.3/5V, PCI-X compatible
PCI Express 1x
Processor
AMD SC520, 133 Mhz
AMD SC520, 133 Mhz
Profibus ASIC
UART High Speed
UART High Speed
Memory
Flash Memory
Interruption
16 Mbytes SDRAM
16 Mbytes SDRAM
4 Mbytes
4 Mbytes
Hardware Plug&Play
Hardware Plug&Play
DPRAM Address
Hardware Plug&Play (32 Kbytes)
Hardware Plug&Play (32 Kbytes)
Discrete Input
1 x Opto-coupled discrete input,
Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
1 x Opto-coupled discrete input,
Voltage -> +10 to +30 V DC or 24 V AC (50-60 Hz)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
Dimensions (LxW)
168mm x 107mm (6.61" x 4.21")
168mm x 107mm (6.61" x 4.21")
Consumption
5.5W (max. 1.2A)
5.5W (max. 1.2A)
Operating T°
0ºC (32ºF) up to +65°C (149°F)
0ºC (32ºF) up to +65°C (149°F)
Storage T°
-40º C (-40°F) up to +85ºC (185º F)
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
YES
-40º C (-40°F) up to +85ºC (185º F)
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
YES
Port type
1 Profibus port (EN 50170)
1 Profibus port (EN 50170)
Connector
Profibus D-Sub, 9 pin, female
Profibus D-Sub, 9 pin, female
LED Indicator
2 bicolor Leds: bus fault and communication status
2 bicolor Leds: bus fault and communication status
Electrical Interface
RS485 optical insulation (500 V)
RS485 optical insulation (500 V)
Baud Rate
9.6 kbps ↔ 12 Mbps
9.6 kbps ↔ 12 Mbps
Discrete Output
EMC Compliance
RoHS Compliance
Communication port
Port for remote configuration and diagnostic
Port Type
Ethernet port
Ethernet port
Connector type
RJ45
RJ45
LED indicators
4 Leds - TX/RX/Link/100 Mbps
4 Leds - TX/RX/Link/100 Mbps
Electrical interface
Ethernet
Ethernet
Speed
10/100 Mbps
10/100 Mbps
Technical data
Direct-Link™
PC104-DPIO
Direct-Link™
CPCI-DPIO
Key Benefits
• Fast data exchange (on-board processor take off the load of the host CPU)
• Speed up to 12 Mbps
• Serial or Ethernet (only for PCU card) port for remote configuration to use with exotic OS
• DP-V0 Master Class 1 & 2/ Slave simultaneously
Hardware
Unit
PC/104 bus
CompactPCI bus, 5V
Processor
AMD SC520, 100 Mhz
AMD SC520, 133 Mhz
Profibus ASIC
ASPC2
ASPC2
Memory
8 Mbytes SDRAM
8 Mbytes SDRAM
Flash Memory
512 Kbytes
512 kbytes
Interruption
2, 3, 4, 5, 6, 7, 10, 11, 12, 14, 15
Hardware Plug&Play
DPRAM Address
From C8000 to DE000 (8 Kbytes used per card)
Hardware Plug&Play (16 Kbytes)
Discrete Input
1 x Opto-coupled discrete input,
Voltage -> +10 to +30V DC or 24V AC (50-60 Hz)
1 x Opto-coupled discrete input,
Voltage -> +10 to +30V DC or 24V AC (50-60 Hz)
Discrete Output
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
1 x "WatchDog" output contact free from potential
(floating) (24 V DC, 0.25 A)
Dimensions (LxW)
95mm x 90mm (3.74" x 3.54")
100mm x 160mm (3.93" x 6.29") - 3U
Consumption
5.5W (max. 1.2A)
5,5W (max. 1.2A)
Operating T°
0ºC (32°F) up to +65ºC (149ºF)
0º C (32º F) ↔ +65º C (149º F)
Storage T°
-40º C (-40°F) up to +85ºC (185º F)
-40º C (-40°F) up to +85ºC (185º F)
EMC Compliance
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
EN55022 Class B, EN61000-6-2, EN61000-3-2,
EN61000-3-3
RoHS Compliance
NO
YES
1 Profibus port (EN 50170)
LED Indicator
1 Profibus port (EN 50170)
In standard: HE13 (2 x 5 pins) or in option: 9-pin, SubD, female
2 bicolor Leds: bus fault and communication status
Electrical Interface
RS485 optical insulation (500 V)
RS485 optical insulation (500 V)
Baud Rate
9.6 kbps ↔ 12 Mbps
9.6 kbps ↔ 12 Mbps
Communication port
Port type
Connector
Profibus D-Sub, 9 pin, female
2 bicolor Leds: bus fault and communication status
Port for remote configuration and diagnostic
Port Type
Asynchronous Serial port
Asynchronous Serial port
Connector type
HE13 (2 x 5 pins)
9-pin, Sub-D, male
LED indicators
-
2 Leds - TX/RX
Electrical interface
RS232 – 2 signals
RS232 – 2 signals
Speed
9600, 38400, 115200 bps
9600, 38400, 115200 bps
Direct-Link™ Profibus-DP
Protocol Specifications
All BradCommunications™ Direct-Link™ networks interface cards for Profibus-DP support following protocols:
ƒ
ƒ
ƒ
DP-V0 Master/Scanner Class-1 & -2 and Slave modes simultaneously
DP-V0 Slave passive mode only
DP-V1 Master Class-1 & -2 (for PCU card)
DP Master features
Access Modes
DPV0 Master/Scanner Class-1 for optimized exchange of input/output data with the slaves
(Data_Exchange).
DP-V0 Master Class-2 for:
ƒ
Slave diagnostics
ƒ
Reading inputs/outputs of a slave
ƒ
Reading configuration data
ƒ
Changing the slave address.
DP-V1 Master Class-1 & -2:
ƒ
Read Data Block Class 1
ƒ
Write Data Block Class 1
ƒ
Read Data Block Class 2
ƒ
Write Data Block Class 2
ƒ
Abort Data Block Comm Class 2
Multi-master mode
Watchdog control
Input/Output Data
Yes (able to share the bus with other DP masters connected on the network)
Yes, enables the master to switch into error if no data has been exchanged during this period
(Bus Fault)
ƒ Memory of I/O data image:
o PC/104:
up to 2Kbytes
o PCI-Universal: up to 8Kbytes
o PCI Express:
up to 8Kbytes
o CompactPCI:
up to 4Kbytes
ƒ
Manage up to 244 data bytes per slave
ƒ
Automatic organization of I/O data in the DPRAM memory
Max. DP Slave
Connect up to 126 slaves
Data consistency
Yes (i.e. user gets the data up to 122 bytes of a slave from one and the same DP cycle)
Data format
Direct access to variable types (bit, byte, word, double word)
Local DP slave
Run simultaneously with Master modes.
Offers data exchange with another master on the network. The size of the input and output data
is user-definable, and all exchange combinations are possible (from 0 to 244 bytes). The slave
can ensure data consistency up to 122 bytes. (see DP-Slave features below for details).
DP Slave passive features
Access Mode
DP-V0 Slave passive (no management of Profibus token)
Input memory size
Configurable from 0 to 244 bytes
Output memory size
Configurable from 0 to 244 bytes
Slave address
Configurable from 0 to 126 by software configuration
GSD files
Provided on the CD-Rom
Data Format
Configurable Intel or Motorola
Address Assignment
Master (Set_Slave_Address)
Not supported
Extended Diagnostic
Not supported
Direct-Link™ Profibus-DP
Software tools
The core of BradCommunications™ Direct-Link™ PC Network Interface cards lies in
effective software tools enabling fast integration of industrial communication into your
applications.
More precisely, Direct-Link™ package includes configuration software called Console
used to set up card, network and equipments connected to the fieldbus. The Console
performs dynamic network diagnostic and allows defining access items to the
input/output data used by the software interfaces (OPC server, ActiveX Control,
DAServer, DDE/SuiteLink server).
- Device Configuration -
The console is common to all fieldbuses offer as EtherNet/IP, PROFINET IO, Modbus
TCP, DeviceNet and CANopen. Other great features managed by the Console:
- Powerful Graphical User Interface
- Automatic detection of cards plugged into the host computer
- User configuration manager: create, backup and restore many user configurations
- Manual or Automatic device configuration
- Profibus scanner (automatic configuration by detection of slaves connected)
- GSD library. Add/Remove GSD file
- Diagnostic monitor; scan devices connected on the bus, able to change DP slave
address
- Card Status indicator: allows you to quickly find the initialization status of each
card
- Profibus Network Monitoring -
- Troubleshooting & Testing tool –
Ordering Information
Part Number
SAP
DRL-DPM-PCU
1120110008
DRL-DPM-PCIE
1120115028
DRL-DPM-CPI
1120185004
BradCommunications™ Direct-Link™ CPCI-DPIO ProfibusDP Master/Slave 12 Mbps, CompactPCI bus 3U
DRL-DPM-104
1120130003
BradCommunications™ Direct-Link™ PC104-DPIO
Profibus-DP Master/Slave 12 Mbps, PC/104 bus
- Browsing of OPC Server -
Product Description
BradCommunications™ Direct-Link™ PCU-DPIO ProfibusDP Master/Slave 12 Mbps, PCI-Universal bus, 3.3/5V
BradCommunications™ Direct-Link™ PCU-DPIO ProfibusDP Master/Slave 12 Mbps, PCI Express 1x
To contact us: www.woodhead.com
North America: US: + 1 800 225 7724 – Canada: +1 519 725 5136
Europe:
France: +33 2 32 96 04 20 – Germany: +49 7252 94 96 0– Italy: +39 010 59 30 77 –
United Kingdom: +44 1495 356300
Asia:
Shanghai, China: +86 21-5835-9885 - Tianjin, China: +86 22-23321717
Singapore: +65 6268-6868 – Yamato, Japan: +81 46-265-2428 – Nagoya, Japan: +81 52-221-5950
Brad is a registered trademark and BradCommunications and applicom are trademarks of Molex Incorporated. © 2008 Molex