POWER TRANSFORMER LP12-3800 (F) SERIES 1. CONFIGURATION & DIMENSIONS : A 6 4 8 3 7 B B B 16.70 (0.657) H Max. W 2 B 5 1 PC terminal plug-in mounting 6.00 (0.236) Ref. 1.00 (0.041) 56.00 (2.205) PCB Pattern L UNIT : mm (inch) SIZE L W H A B gram 48 80.40 62.70 34.50 57.00 15.00 595.34 (3.168) (2.475) (1.358) (2.244) (0.590) 2. SCHEMATIC : 3 7 Primaries 4 115/230V 50/60Hz 2 8 6 1 5 indicates polarity 3. ELECTRICAL CHARACTERISTICS ( @ 25°C ) : a. Primary Voltage b. NO Load Primary Current Input AC 115V 60Hz . Input AC 230V 50Hz . c. Secondary Voltage (±5%) d. Secondary Load Current e. Full Load Primary Current Input AC 115V 60Hz . Input AC 230V 50Hz . f. Full Load Secondary Voltage (±5%) g. DC Resistance Pin 1-2 Pin 3-4 Pin 5-6 Pin 7-8 h. Insulation Resistance i. Withstand Voltage (Hi-Pot) j. Temperature Rise k. Core Size AC 115/230 V 50/60 Hz . Less Than 70mA . Less Than 70mA . Series AC - V . Parallel AC - V . Series 3800mA . Parallel 7600mA . Less Than - mA . Less Than - mA . Series 12.60V . Parallel 6.30V . Primary = 34 Ohm . = 34 Ohm . Secondary = - Ohm . = - Ohm . DC 500V 100Meg Ohm Of More . AC 1500V 60Hz 1 Minutes . Less Than 60 Deg C . UI-48 x 16.20 m/m . NOTE : Specifications subject to change without notice. Please check our website for latest information. 05.06.2008 SUPERWORLD ELECTRONICS (S) PTE LTD PG. 1