TRUMPOWER TM200-Q45

TRUMPower
200 WATT MEDICAL POWER SUPPLIES
D E SCR IPTION
TM200 SERIES
(MDD)
Comprising single and multiple output models
with 200 watts of continuous output power, the
TM200 series is specially designed for medical
applications. Auto-ranging input allows them to
operate from any line voltage throughout the
world without a selector strap. All auxiliary
outputs are with magnetic amplifier or linear
regulator to keep regulation. The units are
constructed on a printed circuit board with a
U-bracket for mechanical support and heat
sinking. A cover-and-fan assembly can be
added during manufacturing.
Saf et y Sta n da rd A ppr o va ls:
F EATU R E S
‧
‧
‧
‧
‧
‧
‧
Low safety ground leakage current
M e e t E N 5 5 0 11 a n d F C C c l a s s B
Auto-ranging input
Short-circuit protection with auto-recovery
Pow er Fail Detect( PFD) signal
100% burn-in at full rated load
Optional cover-and-fan assembly
UL 2601-1
CSA C22.2 No. 601.1
TÜV EN60601-1
IN PUT S PE C IF ICAT ION S
E N V IR O N M ENTA L SP E C IF ICATI O N S
I n p u t v o l ta g e :
Operating temperature:
Storage temperature:
Relative humidity:
Derating:
Input frequency:
Input current:
Leakage current:
9 0 t o 1 3 0 VA C , o r 1 8 0 t o
2 6 4 VA C ( a u t o - r a n g i n g )
47 to 63 Hz
4 . 5 A ( r m s ) f o r 11 5 VA C
2 . 6 A ( r m s ) f o r 2 3 0 VA C
9 0 µ A m a x . @ 11 5 VA C , 6 0 H z
1 5 µ A m a x . @ 2 3 0 VA C , 5 0 H z
Cooling:
0ºC to +70ºC
-40ºC to +85ºC
5% to 95% non-condensing
Derate from 100% at +50ºC
linearly to 50% at +70ºC
2 5 C F M f o r c e d a i r, p r o v i d e d
on covered version, to be
provided f o r U - b r a c k e t
version by user
OUTPUT SPECIFICATIONS
GENERAL SPECIFICATIONS
Output voltage/current: See rating chart
Switching frequency:
Efficiency:
Hold-up time:
Line regulation:
Inrush current:
Total output power:
200 watts maximum
Ripple and noise:
2% peak to peak maximum
Overvoltage protection: Provided on output #1 only; set at
112 – 132% of its nominal output
voltage
Overcurrent protection: All outputs protected to short
circuit conditions
Temperature coefficient:All outputs ±0.04%/ºC maximum
Transient response:
Maximum excursion of 4% or
better on all models, recovering to
1% of final value within 500µs
after a 25% step load change
PFD signal:
TTL logic high for normal
operation and TTL logic low upon
loss of input power. This signal
appears at least 1 ms prior to +5V
output dropping 5% below its
nominal value. This signal also
provides a minimum delay of 100
ms after +5V is within regulation.
64KHz ±5KHz
70% minimum on all models
12 msec minimum at 110VAC
±0.5% maximum at full load
20 amps @ 115VAC, or 40 amps @
230VAC, at 25ºC cold start
Withstand voltage:
4000VAC from input to output
1500VAC from input to ground
500VAC from output to ground
MTBF:
450,000 hours at full load at 25ºC
ambient, calculated per
MIL-HDBK-217F
EMC Performance (EN60601-1-2: 2 0 0 1 )
E N 5 5 0 11 :
Class B conducted, Class B radiated
FCC:
Class B conducted, Class B radiated
VCCI:
Class B conducted, Class B radiated
EN61000-3-2:
Harmonic distortion, Class A
EN61000-3-3:
Line flicker
EN61000-4-2:
ESD, ±8KV air and ±4KV contact
EN61000-4-3:
Radiated immunity, 3V/m
EN61000-4-4:
Fast transient/burst, ±1KV
EN61000-4-5:
Surge, ±1KV diff, ±2KV com.
EN61000-4-6:
Conducted immunity, 3Vrms
EN61000-4-8:
Magnetic field immunity, 1A/m
E N 6 1 0 0 0 - 4 - 11 :
Voltage dips, 30% reduction for 500ms
and >95% reduction for 10ms
Interruptions, >95% for 5000ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com
MEDICAL GRADE
TM200 SERIES
OUTPUT VOLTAGE/CURRENT RATING CHART
Product No.
TM200-S05
TM200-S12
TM200-S15
TM200-S24
TM200-S30
TM200-S48
TM200-D23
TM200-D24
TM200-D25
TM200-T30
TM200-T31
TM200-T32
TM200-T33
TM200-Q40
TM200-Q41
TM200-Q42
TM200-Q44
TM200-Q45
Notes:
Vnom.
5V
12V
15V
24V
30V
48V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
+5V
Output #1
Imin.
Imax. Tol.
3.0A
40A 2%
1.2A
16.7A 2%
1.0A
13.4A 2%
0.6A
8.4A 2%
0.5A
6.7A 2%
0.5A
4.2A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
3.0A
30A 2%
Output #2
Vnom. Imin. Imax.
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
+12V 0A
8A
+15V 0A
6A
+24V 0A
4A
+12V 0A
8A
+12V 0A
8A
+15V 0A
6A
+15V 0A
6A
+12V 0A
8A
+15V 0A
6A
+12V 0A
8A
+12V 0A
8A
+12V 0A
8A
Tol.
4%
4%
4%
4%
4%
4%
4%
4%
4%
4%
4%
4%
Output #3
Vnom. Imin. Imax.
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
-5V
0A
6A
-12V
0A
4A
-15V
0A
4A
-12V
0A
4A
-12V
0A
4A
-15V
0A
4A
-12V
0A
4A
-15V
0A
4A
-12V
0A
4A
Tol.
4%
4%
4%
4%
4%
4%
4%
4%
4%
Output #4
Vnom. Imin. Imax.
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
(N/A)
5V
0A
6A
24V
0A
4A
12V
0A
4A
15V
0A
4A
24V
0A
4A
Tol.
4%
4%
4%
4%
4%
Maximum
Output
Power
200W
200W
200W
200W
200W
200W
200W
200W
200W
200W
200W
200W
200W
200W
200W
200W
200W
200W
(1) Add suffix “C” for enclosed format, e.g. TM200-Q45C.
(2) Peak current is 12A on +12V, 9A on +15V and 6A on +24V.
(3) Output #4 is floating. It can be connected externally for positive or negative output.
(4) 200 watts for “C” version with a cover-and-fan assembly. 150 watts U-bracket version without moving air (maximum current of output #1
& #2 derated to 70%), or 200 watts with 25 CFM forced air provided by user.
(5) When the remote sense facility is not used, +Sense must be connected to +V, and –Sense to return, on P2 connector.
(6) All models may be operated at no-load. At no-load, output voltage tolerance increases to 10%
MECHANICAL SPECIFICATIONS
NOTES:
1.
Dimensions shown in inch [mm]
2.
Tolerance 0.02 [0.5] maximum
3.
Input connector P1 is Beau Inc. P/N 72-5-03C, output connector
P2 is Beau Inc. P/N 72-5-09C. Screws are #6-32 on 0.375 inch
centers.
4.
Connector P3 mates with Molex housing 22-01-1043 and Molex
40445 series crimp terminal.
5.
Connector P4 mates with Molex housing 22-01-1023 and Molex
40445 series crimp terminal.
6.
P4 is for DC fan rated 24V/0.12A (models TM200-S24, -S30,
-D25), or 12V/0.2A (other models)
7.
Weight:
1.40 Kgs (3.08Lbs.) approx. for U-bracket version
1.60 Kgs (3.52 Lbs.) approx. for “C” version
PIN CHART
CON
Product No.
TM200-S05
TM200-S15
TM200-S30
TM200-D23
TM200-D25
TM200-T30
TM200-T32
TM200-Q40
TM200-Q42
TM200-Q45
PIN
P1
1
TM200-S12
AC
TM200-S24
LIVE
TM200-S48
TM200-D24 AC
LIVE
TM200-T31 AC
TM200-T33 LIVE
TM200-Q41
AC
TM200-Q44
LIVE
2
P2
3
1, 2
AC
AC
-SENSE
NEUTRAL GROUND
3, 4, 5
RET.
6
P3
7
8
9
OUTPUT OUTPUT OUTPUT
+SENSE
#1
#1
#1
AC
AC
OUTPUT COM. OUTPUT
N.C.
NEUTRAL GROUND
#1
RET.
#2
AC
AC
OUTPUT COM. OUTPUT OUTPUT
NEUTRAL GROUND
#1
RET.
#2
#3
AC
AC
OUTPUT COM. OUTPUT OUTPUT
NEUTRAL GROUND
#1
RET.
#2
#3
1
2
3
4
FAN
COM.
RET.
COM.
RET.
PFD
COM.
RET.
COM.
RET.
COM.
RET.
COM.
RET.
COM.
RET.
COM.
RET.
N.C.
N.C.
FAN
N.C.
N.C.
FAN
OUTPUT
OUTPUT
#4
#4
RETURN
FAN
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA
Phone: 408-988-6616 ● Fax: 408-988-6622 ● email: [email protected] ● Website: www.TRUMPower.com
PFD
PFD
PFD