DBLECTRO FRV005-240F

NO.
Product Specification and Approval Sheet Version
PQ24-101E
3
Page
1/4
Radial Leaded PTC Resettable Fuse: FRV Series
Preliminary
1. Summary
(a) RoHS Compliant (Lead Free) Product
(b) Applications: Line Voltage Power Supply, Transformer and Appliances
(c) Product Features: Low hold current, Solid state, Radial leaded product ideal for up
to 265VAC/DC
(d) Operation Current: 50mA~550mA
(e) Maximum Operating Voltage: 240VAC/DC
(f) Maximum Interrupt Voltage: 265VAC/DC
(g) Temperature Range : -40℃ to 85℃
2. Agency Recognition
UL:
File No. Pending
C-UL: File No. Pending
TÜV:
File No. Pending
.
3. Electrical Characteristics (23℃)
Part
Number
FRV005-240F
FRV008-240F
FRV012-240F
FRV016-240F
FRV025-240F
FRV033-240F
FRV040-240F
FRV055-240F
Hold
Trip Max.Time Maximum Rated Typical
Current Current to Trip Current Voltage Power
IH, A
IT, A
0.05
0.08
0.12
0.16
0.25
0.33
0.40
0.55
0.12
0.19
0.30
0.37
0.56
0.74
0.90
1.25
at 5xIH
15.0
15.0
15.0
15.0
18.5
18.5
24.0
26.0
IMAX, A
1.0
1.2
1.2
2.0
3.5
4.5
5.5
7.0
VMAX, VAC Pd, W
240
240
240
240
240
240
240
240
0.70
0.80
1.00
1.40
1.50
1.70
2.00
3.40
Resistance
Tolerance
RMIN
R1MAX
ohms
ohms
18.50
7.40
3.00
2.50
1.30
0.83
0.60
0.45
65.00
26.00
12.00
7.80
3.80
2.60
1.90
1.45
IH=Hold current-maximum current at which the device will not trip at 23 ℃ still air.
IT=Trip current-minimum current at which the device will always trip at 23 ℃ still air.
V MAX=Maximum voltage device can withstand without damage at its rated current.
I MAX= Maximum fault current device can withstand without damage at rated voltage (V MAX).
Pd=Typical power dissipated from device when in tripped state in 23 ℃ still air environment.
RMIN=Minimum device resistance at 23℃.
R1MAX=Maximum device resistance at 23℃, 1 hour after tripping.
Physical specifications:
Lead material: FRV005-240F~FRV016-240F Tin plated copper, 24AWG.
FRV025-240F~FRV040-240F Tin plated copper, 22AWG.
FRV055-240F Tin plated copper, 20AWG.
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meets UL-94V-0 requirement.
DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com
NO.
Product Specification and Approval Sheet Version
PQ24-101E
3
Page
2/4
4. Production Dimensions (millimeter)
FRV 005-240F~FRV016-240F
Lead Size: 24AWG
Φ 0.51 mm Diameter
FRV025-240F~FRV040-240F
Lead Size: 22AWG
Φ 0.65 mm Diameter
Part
A
Number
Maximum
FRV005-240F
8.3
FRV008-240F
8.3
FRV012-240F
8.3
FRV016-240F
9.9
FRV025-240F
9.6
FRV033-240F
11.4
FRV040-240F
11.5
FRV055-240F
14.0
FRV055-240F
Lead Size: 20AWG
Φ 0.81 mm Diameter
B
C
D
E
Maximum
10.7
10.7
10.7
12.5
17.4
16.5
19.5
21.7
Typical
5.1
5.1
5.1
5.1
5.1
5.1
5.1
5.1
Minimum
7.6
7.6
7.6
7.6
7.6
7.6
7.6
7.6
Maximum
3.8
3.8
3.8
3.8
3.8
3.8
3.8
4.1
5. Thermal Derating Curve
Thermal Derating Curve - FRV Series
Precent of Rated Hold and Trip
Current
200%
150%
100%
50%
0%
-20
0
20
40
60
80
Ambient Temperature (C)
DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com
NO.
Product Specification and Approval Sheet Version
PQ24-101E
3
Page
3/4
6. Typical Time-To-Trip at 23℃
A= FRV005-240F
B= FRV008-240F
1000
C= FRV012-240F
D= FRV016-240F
C
100
D
E
G
F
H
F= FRV033-240F
G= FRV040-240F
H= FRV055-240F
Time-to-trip (S)
E= FRV025-240F
A
10
B
1
0.1
0.01
0.1
1
10
Fault current (A)
7. Material Specification
Lead material:FRV005-240F~FRV016-240F Tin plated copper, 24AWG.
FRV025-240F~FRV040-240F Tin plated copper, 22AWG.
FRV055-240F Tin plated copper, 20AWG.
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating:Flame retardant epoxy, meets UL-94V-0 requirement.
8. Part Numbering and Marking System
Part Numbering System
Part Marking System
FRV □ □ □ - □ □ □ F
F
RV □ □ F
RoHS Compliant / Lead Free
Voltage rating
Current rating
F
RV12F
41AB
Logo
RoHS Compliant / Lead Free
Part Identification
Product Family
□
□ □ □
Example
Date Code/Lot Number
DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com
NO.
Product Specification and Approval Sheet Version
PQ24-101E
3
Page
4/4
Warning: - Each product should be carefully evaluated and tested for their suitability of application.
- Operation beyond the specified maximum rating or improper use may result in damage and possible
electrical arcing and/or flame.
- PPTC device are intended for occasional overcurrent protection. Application for repeated overcurrent
condition and/or prolonged trip are not anticipated.
- Avoid contact of PPTC device with chemical solvent, including some inert material such as silicone based
oil, lubricant and etc. Prolonged contact will damage the device performance.
- Additional protection mechanism are strongly recommended to be used in conjunction with the PPTC
device for protection against abnormal or failure conditions.
- Avoid use of PPTC device in a constrained space such as potting material, housing and containers
where have limited space to accommodate device thermal expansion and/or contraction.
NOTE : Specification subject to change without notice.
DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com