NO. Product Specification and Approval Sheet Version PQ24-101E 3 Page 1/4 Radial Leaded PTC Resettable Fuse: FRV Series Preliminary 1. Summary (a) RoHS Compliant (Lead Free) Product (b) Applications: Line Voltage Power Supply, Transformer and Appliances (c) Product Features: Low hold current, Solid state, Radial leaded product ideal for up to 265VAC/DC (d) Operation Current: 50mA~550mA (e) Maximum Operating Voltage: 240VAC/DC (f) Maximum Interrupt Voltage: 265VAC/DC (g) Temperature Range : -40℃ to 85℃ 2. Agency Recognition UL: File No. Pending C-UL: File No. Pending TÜV: File No. Pending . 3. Electrical Characteristics (23℃) Part Number FRV005-240F FRV008-240F FRV012-240F FRV016-240F FRV025-240F FRV033-240F FRV040-240F FRV055-240F Hold Trip Max.Time Maximum Rated Typical Current Current to Trip Current Voltage Power IH, A IT, A 0.05 0.08 0.12 0.16 0.25 0.33 0.40 0.55 0.12 0.19 0.30 0.37 0.56 0.74 0.90 1.25 at 5xIH 15.0 15.0 15.0 15.0 18.5 18.5 24.0 26.0 IMAX, A 1.0 1.2 1.2 2.0 3.5 4.5 5.5 7.0 VMAX, VAC Pd, W 240 240 240 240 240 240 240 240 0.70 0.80 1.00 1.40 1.50 1.70 2.00 3.40 Resistance Tolerance RMIN R1MAX ohms ohms 18.50 7.40 3.00 2.50 1.30 0.83 0.60 0.45 65.00 26.00 12.00 7.80 3.80 2.60 1.90 1.45 IH=Hold current-maximum current at which the device will not trip at 23 ℃ still air. IT=Trip current-minimum current at which the device will always trip at 23 ℃ still air. V MAX=Maximum voltage device can withstand without damage at its rated current. I MAX= Maximum fault current device can withstand without damage at rated voltage (V MAX). Pd=Typical power dissipated from device when in tripped state in 23 ℃ still air environment. RMIN=Minimum device resistance at 23℃. R1MAX=Maximum device resistance at 23℃, 1 hour after tripping. Physical specifications: Lead material: FRV005-240F~FRV016-240F Tin plated copper, 24AWG. FRV025-240F~FRV040-240F Tin plated copper, 22AWG. FRV055-240F Tin plated copper, 20AWG. Soldering characteristics: MIL-STD-202, Method 208E. Insulating coating:Flame retardant epoxy, meets UL-94V-0 requirement. DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com NO. Product Specification and Approval Sheet Version PQ24-101E 3 Page 2/4 4. Production Dimensions (millimeter) FRV 005-240F~FRV016-240F Lead Size: 24AWG Φ 0.51 mm Diameter FRV025-240F~FRV040-240F Lead Size: 22AWG Φ 0.65 mm Diameter Part A Number Maximum FRV005-240F 8.3 FRV008-240F 8.3 FRV012-240F 8.3 FRV016-240F 9.9 FRV025-240F 9.6 FRV033-240F 11.4 FRV040-240F 11.5 FRV055-240F 14.0 FRV055-240F Lead Size: 20AWG Φ 0.81 mm Diameter B C D E Maximum 10.7 10.7 10.7 12.5 17.4 16.5 19.5 21.7 Typical 5.1 5.1 5.1 5.1 5.1 5.1 5.1 5.1 Minimum 7.6 7.6 7.6 7.6 7.6 7.6 7.6 7.6 Maximum 3.8 3.8 3.8 3.8 3.8 3.8 3.8 4.1 5. Thermal Derating Curve Thermal Derating Curve - FRV Series Precent of Rated Hold and Trip Current 200% 150% 100% 50% 0% -20 0 20 40 60 80 Ambient Temperature (C) DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com NO. Product Specification and Approval Sheet Version PQ24-101E 3 Page 3/4 6. Typical Time-To-Trip at 23℃ A= FRV005-240F B= FRV008-240F 1000 C= FRV012-240F D= FRV016-240F C 100 D E G F H F= FRV033-240F G= FRV040-240F H= FRV055-240F Time-to-trip (S) E= FRV025-240F A 10 B 1 0.1 0.01 0.1 1 10 Fault current (A) 7. Material Specification Lead material:FRV005-240F~FRV016-240F Tin plated copper, 24AWG. FRV025-240F~FRV040-240F Tin plated copper, 22AWG. FRV055-240F Tin plated copper, 20AWG. Soldering characteristics: MIL-STD-202, Method 208E. Insulating coating:Flame retardant epoxy, meets UL-94V-0 requirement. 8. Part Numbering and Marking System Part Numbering System Part Marking System FRV □ □ □ - □ □ □ F F RV □ □ F RoHS Compliant / Lead Free Voltage rating Current rating F RV12F 41AB Logo RoHS Compliant / Lead Free Part Identification Product Family □ □ □ □ Example Date Code/Lot Number DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com NO. Product Specification and Approval Sheet Version PQ24-101E 3 Page 4/4 Warning: - Each product should be carefully evaluated and tested for their suitability of application. - Operation beyond the specified maximum rating or improper use may result in damage and possible electrical arcing and/or flame. - PPTC device are intended for occasional overcurrent protection. Application for repeated overcurrent condition and/or prolonged trip are not anticipated. - Avoid contact of PPTC device with chemical solvent, including some inert material such as silicone based oil, lubricant and etc. Prolonged contact will damage the device performance. - Additional protection mechanism are strongly recommended to be used in conjunction with the PPTC device for protection against abnormal or failure conditions. - Avoid use of PPTC device in a constrained space such as potting material, housing and containers where have limited space to accommodate device thermal expansion and/or contraction. NOTE : Specification subject to change without notice. DB LECTRO Inc. 3600 boul. Matte suite i Brossard Qc J4Y-2Z2 tel:(450)-444-1424 fax:(450)-444-4714 www.dblectro.com