SN54F257, SN74F257 QUADRUPLE 2-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SDFS065A – D2932, MARCH 1987 – REVISED OCTOBER 1993 • • • SN54F257 . . . J PACKAGE SN74F257 . . . D OR N PACKAGE (TOP VIEW) 3-State Outputs Interface Directly With System Bus Provides Bus Interface From Multiple Sources in High-Performance Systems Package Options Include Plastic Small-Outline Packages, Ceramic Chip Carriers, and Standard Plastic and Ceramic 300-mil DIPs A /B 1A 1B 1Y 2A 2B 2Y GND description The ′F257 is designed to multiplex signals from 4-bit data sources to 4-output data lines in bus-organized systems. The 3-state outputs will not load the data lines when the output enable (OE) input is at a high logic level. A /B A B H X X X Z L L L X L L L H X H L H X L L L H X H H 3 14 4 13 5 12 6 11 7 10 8 9 VCC OE 4A 4B 4Y 3A 3B 3Y 4 3 2 1 20 19 18 5 17 6 16 7 15 8 14 9 10 11 12 13 4A 4B NC 4Y 3A 2Y GND NC 3Y 3B OE 15 1A A/B NC VCC OE 1B 1Y NC 2A 2B FUNCTION TABLE OUTPUT Y 16 2 SN54F257 . . . FK PACKAGE (TOP VIEW) The SN54F257 is characterized for operation over the full military temperature range of – 55°C to 125°C. The SN74F257 is characterized for operation from 0°C to 70°C. INPUTS 1 NC – No internal connection logic symbol† 15 OE 1 A /B 1A 1B 2A 2B 3A 3B 4A 4B EN G1 2 3 1 MUX 4 1 1Y 5 7 6 2Y 11 9 10 3Y 14 12 13 4Y † This symbol is in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the D, J, and N packages. Copyright 1993, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 2–1 SN54F257, SN74F257 QUADRUPLE 2-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SDFS065A – D2932, MARCH 1987 – REVISED OCTOBER 1993 logic diagram (positive logic) OE A/B 1A 1B 2A 15 1 2 4 5 7 2B 3A 3B 4A 4B 1Y 3 2Y 6 11 9 3Y 10 14 12 4Y 13 Pin numbers shown are for the D, J, and N packages. absolute maximum ratings over operating free-air temperature range (unless otherwise noted)† Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V Input voltage range (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 1.2 V to 7 V Input current range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 30 mA to 5 mA Voltage range applied to any output in the disabled or power-off state . . . . . . . . . . . . . . . . . . . – 0.5 V to 5.5 V Voltage range applied to any output in the high state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC Current into any output in the low state: SN54F257 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 mA SN74F257 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 mA Operating free-air temperature range: SN54F257 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 55°C to 125°C SN74F257 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 70°C Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: The input voltage ratings may be exceeded provided the input current ratings are observed. 2–2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 SN54F257, SN74F257 QUADRUPLE 2-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SDFS065A – D2932, MARCH 1987 – REVISED OCTOBER 1993 recommended operating conditions SN54F257 VCC VIH Supply voltage VIL IIK Low-level input voltage IOH IOL High-level output current TA Operating free-air temperature High-level input voltage SN74F257 MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.5 5 5.5 2 2 Input clamp current Low-level output current V V 0.8 0.8 V – 18 – 18 mA –3 –3 mA 24 mA 70 °C 20 – 55 UNIT 125 0 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER VIK VOH VCC = 4.5 V, VCC = 4 4.5 5V VCC = 4.75 V, MIN II = – 18 mA IOH = – 1 mA VOL 5V VCC = 4 4.5 IOZH IOZL VCC = 5.5 V, VCC = 5.5 V, VO = 2.7 V VO = 0.5 V II IIH VCC = 5.5 V, VCC = 5.5 V, VI = 7 V VI = 2.7 V IIL IOS‡ VCC = 5.5 V, VCC = 5.5 V, VI = 0.5 V VO = 0 SN74F257 TYP† MAX MIN – 1.2 IOH = – 3 mA IOH = – 1 mA to – 3 mA IOL = 20 mA IOL = 24 mA ICCH ICCL SN54F257 TYP† MAX TEST CONDITIONS – 1.2 2.5 3.4 2.5 3.4 2.4 3.3 2.4 3.3 2.7 0.3 0.5 0.35 50 50 µA – 50 µA 0.1 0.1 mA 20 20 µA – 0.6 mA –150 mA –150 – 60 15 9 15 Condition B 14.5 22 14.5 22 ICCZ Condition C 15 23 15 † All typical values are at VCC = 5 V, TA = 25°C. ‡ Not more than one output should be shorted at a time, and the duration of the short circuit should not exceed one second. NOTE 2: ICC is measured with the outputs open under the following conditions: A. A/B and all B inputs at 4.5 V, other inputs grounded B. All B inputs at 4.5 V, other inputs grounded C. OE and all B data inputs at 4.5 V, other inputs grounded 23 • DALLAS, TEXAS 75265 V – 50 – 0.6 – 60 0.5 9 POST OFFICE BOX 655303 V V Condition A VCC = 5.5 55V V, See Note 2 UNIT mA 2–3 SN54F257, SN74F257 QUADRUPLE 2-LINE TO 1-LINE DATA SELECTORS/MULTIPLEXERS WITH 3-STATE OUTPUTS SDFS065A – D2932, MARCH 1987 – REVISED OCTOBER 1993 switching characteristics (see Note 3) PARAMETER FROM (INPUT) TO (OUTPUT) VCC = 5 V, CL = 50 pF, R1 = 500 Ω, R2 = 500 Ω, TA = 25°C VCC = 4.5 V to 5.5 V, CL = 50 pF, R1 = 500 Ω, R2 = 500 Ω, TA = MIN to MAX† ′F257 tPLH tPHL A or B Any Y tPLH tPHL A/B Any Y tPZH tPZL G Any Y tPHZ tPLZ G Any Y SN54F257 SN74F257 MIN TYP MAX MIN MAX MIN MAX 2.2 4.1 6 2.2 8 2.2 7 1.2 3.8 5.5 1 8 1.2 6.5 3.7 9.7 13 3.7 15.5 3.7 15 2.7 6.1 8.5 2.7 10.5 2.7 9.5 2.2 5.5 7.5 2.2 9.5 2.2 8.5 2.2 5.1 7.5 2.2 10 2.2 8.5 1.2 3.9 6 1.2 7 1.2 7 1.2 4.1 6 1.2 9.5 1.2 7 † For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. NOTE 3: Load circuits and waveforms are shown in Section 1. 2–4 POST OFFICE BOX 655303 UNIT • DALLAS, TEXAS 75265 ns ns ns ns IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1998, Texas Instruments Incorporated