EPCOS B41858C4108M001

Aluminum electrolytic capacitors
Single-ended capacitors
Series/Type:
B41858
Date:
December 2006
 EPCOS AG 2007. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Single-ended capacitors
B41858
Low impedance 105 °C
Long-life grade capacitors
for professional applications
Applications
For use in output circuits of switch-mode power supplies of
compact design
For professional industrial electronics, telecommunications
and data processing equipment
Automotive electronics
Features
Low impedance at high frequency
Low ESR
High ripple current capability
High reliability and long useful life
Wide temperature range
Construction
Radial leads
Charge-discharge proof, polar
Aluminum case with insulating sleeve
Minus pole marking on the insulating sleeve
Case with safety vent
Delivery mode
Terminal configurations and packing:
Bulk
Taped, Ammo pack
Cut
Kinked
PAPR (protection against polarity reversal):
crimped leads, J leads, bent leads
Refer to chapter "Single-ended capacitors Taping, packing
and lead configurations" for further details and ordering
example.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 2 of 30
B41858
Low impedance 105 °C
Specifications and characteristics in brief
Rated voltage VR
Surge voltage VS
10 ... 100 V DC
1.15 VR
Rated capacitance CR
Capacitance tolerance
22 ... 12000 µF
±20% M
Dissipation factor tan δ
(20 °C, 120 Hz)
For capacitance higher than 1000 µF add 0.02 for every increase of
1000 µF.
VR (V DC)
10
16
25
35
50
63
80
100
tan δ (max.)
0.19
Diameter (mm)
8 ... 12.5
16
18
ESL (nH)
20
26
34
0.16
0.14
0.12
0.10
0.10
0.10
0.08
Leakage current Ileak
(20 °C, 5 min)
Self-inductance ESL
Useful life
105 °C, VR, IAC,R
105 °C, VR, IAC,R
Requirements
Voltage endurance test
105 °C, VR
> 3000 h for d = 8 mm
> 5000 h for d ≥ 10 mm
∆C/C
tan δ
Ileak
≤ ±40% of initial value
≤ 3 times initial specified limit
≤ initial specified limit
3000 h for d = 8 mm
5000 h for d ≥ 10 mm
∆C/C ≤ ±30% of initial value
tan δ ≤ 2 times initial specified limit
Ileak
≤ initial specified limit
Vibration resistance test To IEC 60068-2-6, test Fc:
Displacement amplitude 0.75 mm, frequency range 10 ... 2000 Hz,
acceleration max. 20 g, duration 3 × 2 h.
Capacitor rigidly clamped by the aluminum case.
Post test requirements
IEC climatic category
To IEC 60068-1:
55/105/56 (55 °C/+105 °C/56 days damp heat test)
Sectional specification
IEC 60384-4
Please read Cautions and warnings and
Important notes at the end of this document.
Page 3 of 30
B41858
Low impedance 105 °C
Dimensional drawings
With stand-off rubber seal
Diameters (mm): 8, 10, 12.5, 16, 18
With flat rubber seal
Diameter (mm): 8
Dimensions and weights
Dimensions (mm)
d +0.5
8
10
10
10
12.5
12.5
12.5
12.5
16
16
16
18
18
18
18
18
l
11.5 +1.5
12.5 +1.0
16 +1.0
20 +2.0
20 +2.0
25 +2.0
30 +2.0
40 +2.0
20 +2.0
25 +2.0
31.5 +2.0
20 +2.0
25 +2.0
31.5 +2.0
35 +2.0
40 +2.0
Please read Cautions and warnings and
Important notes at the end of this document.
a ±0.5
3.5
5.0
5.0
5.0
5.0
5.0
5.0
5.0
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
Page 4 of 30
b
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.60 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.05
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
0.80 ±0.1
Approx. weight
g
1.0
1.6
1.9
2.6
3.6
4.5
5.3
7.4
5.5
7.5
7.8
8.0
9.0
11.0
13.0
16.0
B41858
Low impedance 105 °C
Overview of available types
VR (V DC)
10
16
25
35
Case dimensions d × l (mm)
CR (µF)
8
× 11.5
8
× 11.5
10
× 12.5
8
× 11.5
10
× 12.5
120
180
220
270
330
8
× 11.5
390
8
× 11.5
470
8
× 11.5
560
10
× 12.5
680
10
× 12.5
820
10
× 16
1000
10
× 16
8
× 11.5
8
× 11.5
10
× 12.5
10
× 16
10
× 12.5
10
× 16
10
× 20
10
× 20
10
× 16
12.5 × 20
10
× 20
1200
10
× 20
1500
12.5 × 20
12.5 × 25
10
× 20
12.5 × 20
12.5 × 25
16
× 20
12.5 × 40
16 × 25
1800
10
× 20
12.5 × 25
16
× 20
16
18
× 31.5
× 20
2200
12.5 × 20
12.5 × 25
12.5 × 40
16 × 25
18
× 25
2700
12.5 × 25
16
× 20
16
18
× 31.5
× 20
18
× 31.5
3300
12.5 × 25
16 × 20
12.5 × 40
16 × 25
18
× 25
18
× 35
3900
12.5 × 40
16 × 20
16
18
× 31.5
× 20
18
× 31.5
4700
18
× 20
18
× 25
18
× 35
18
× 40
5600
12.5 × 40
18
× 40
6800
16
× 31.5
18
× 31.5
8200
18
× 31.5
18
× 35
10000
18
× 35
18
× 40
12000
18
× 40
Please read Cautions and warnings and
Important notes at the end of this document.
Page 5 of 30
B41858
Low impedance 105 °C
VR (V DC)
50
63
80
100
Case dimensions d × l (mm)
CR (µF)
22
8
× 11.5
27
10
× 12.5
10
× 16
10
× 20
33
8
× 11.5
39
10
× 12.5
56
8
× 11.5
100
8
× 11.5
120
10
× 12.5
82
8
× 11.5
10
× 16
10
× 12.5
10
× 20
10
× 16
12.5 × 20
12.5 × 25
12.5 × 20
150
180
10
× 16
× 20
12.5 × 25
12.5 × 20
12.5 × 30
16 × 20
12.5 × 20
16
× 25
16
18
× 31.5
× 25
12.5 × 25
12.5 × 40
18 × 20
18
× 31.5
18
× 35
18
× 40
10
220
16
270
330
10
× 20
390
470
12.5 × 20
560
12.5 × 25
680
820
1000
12.5 × 30
16 × 20
× 20
16
18
× 31.5
× 25
12.5 × 30
12.5 × 40
16 × 25
18 × 20
18
× 31.5
12.5 × 40
16 × 20
16
18
18
× 35
18
× 40
16
18
16
× 31.5
× 25
× 31.5
× 20
1200
18
× 31.5
1500
18
× 25
18
× 35
1800
18
× 31.5
18
× 40
2200
18
× 35
2700
18
× 40
Other voltage and capacitance ratings are available upon request.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 6 of 30
× 25
12.5 × 40
18 × 20
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 10 V DC
330
8 × 11.5
390
8 × 11.5
470
8 × 11.5
560 10 × 12.5
680 10 × 12.5
820 10 × 16
1000 10 × 16
1800 10 × 20
2200 12.5 × 20
2700 12.5 × 25
3300 12.5 × 25
3300 16 × 20
3900 12.5 × 40
3900 16 × 20
4700 18 × 20
5600 12.5 × 40
6800 16 × 31.5
8200 18 × 31.5
10000 18 × 35
12000 18 × 40
VR = 16 V DC
270
8 × 11.5
330
8 × 11.5
470 10 × 12.5
680 10 × 16
1000 10 × 20
1200 10 × 20
1500 12.5 × 20
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
2.195
2.195
2.195
1.035
1.035
0.946
0.946
0.584
0.496
0.327
0.327
0.307
0.243
0.307
0.271
0.243
0.192
0.165
0.160
0.125
0.727
0.615
0.511
0.429
0.353
0.293
0.240
0.133
0.121
0.098
0.088
0.088
0.074
0.074
0.067
0.061
0.054
0.051
0.047
0.043
0.274
0.274
0.274
0.129
0.129
0.118
0.118
0.073
0.062
0.041
0.041
0.038
0.030
0.038
0.034
0.030
0.024
0.021
0.020
0.016
0.246
0.246
0.246
0.113
0.113
0.105
0.105
0.062
0.060
0.034
0.034
0.033
0.025
0.033
0.031
0.025
0.022
0.020
0.018
0.015
436
436
436
746
746
846
846
1202
1396
2028
2028
2146
2858
2146
2381
2858
3122
3539
3864
4467
654
654
654
1118
1118
1269
1269
1803
2094
3043
3043
3219
4286
3219
3571
4286
4683
5308
5796
6700
B41858C3337M***
B41858C3397M***
B41858C3477M***
B41858C3567M***
B41858C3687M***
B41858C3827M***
B41858C3108M***
B41858C3188M***
B41858C3228M***
B41858C3278M***
B41858C3338M***
B41858D3338M***
B41858C3398M***
B41858D3398M***
B41858C3478M***
B41858C3568M***
B41858C3688M***
B41858C3828M***
B41858C3109M***
B41858C3129M***
1.200
1.200
1.035
0.946
0.584
0.584
0.496
0.749
0.612
0.430
0.297
0.202
0.168
0.135
0.150
0.150
0.129
0.118
0.073
0.073
0.062
0.134
0.134
0.113
0.105
0.062
0.062
0.060
590
590
746
846
1202
1202
1396
885
885
1118
1269
1803
1803
2094
B41858C4277M***
B41858C4337M***
B41858C4477M***
B41858C4687M***
B41858C4108M***
B41858C4128M***
B41858C4158M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for ∅ ≥ 10 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm)
003 = for crimped leads, blister (for ∅ ≥ 16 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 7 of 30
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 16 V DC
1800 12.5 × 25
2200 12.5 × 25
2700 16 × 20
3300 12.5 × 40
3300 16 × 25
3900 16 × 31.5
3900 18 × 20
4700 18 × 25
6800 18 × 31.5
8200 18 × 35
10000 18 × 40
VR = 25 V DC
180
8 × 11.5
220
8 × 11.5
330 10 × 12.5
470 10 × 16
820 10 × 20
1000 12.5 × 20
1500 12.5 × 25
1800 16 × 20
2200 12.5 × 40
2200 16 × 25
2700 16 × 31.5
2700 18 × 20
3300 18 × 25
3900 18 × 31.5
4700 18 × 35
5600 18 × 40
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
0.327
0.327
0.307
0.243
0.251
0.192
0.271
0.217
0.165
0.160
0.125
0.112
0.103
0.084
0.077
0.077
0.065
0.065
0.059
0.048
0.046
0.043
0.041
0.041
0.038
0.030
0.031
0.024
0.034
0.027
0.021
0.020
0.016
0.034
0.034
0.033
0.025
0.029
0.022
0.031
0.024
0.020
0.018
0.015
2028
2028
2146
2858
2483
3122
2381
2941
3539
3864
4467
3043
3043
3219
4286
3724
4683
3571
4412
5308
5796
6700
B41858C4188M***
B41858C4228M***
B41858C4278M***
B41858D4338M***
B41858C4338M***
B41858D4398M***
B41858C4398M***
B41858C4478M***
B41858C4688M***
B41858C4828M***
B41858C4109M***
1.200
1.200
1.035
0.946
0.584
0.496
0.327
0.307
0.243
0.251
0.192
0.271
0.217
0.165
0.160
0.125
0.982
0.804
0.536
0.376
0.216
0.177
0.118
0.098
0.092
0.092
0.075
0.075
0.069
0.058
0.054
0.050
0.150
0.150
0.129
0.118
0.073
0.062
0.041
0.038
0.030
0.031
0.024
0.034
0.027
0.021
0.020
0.016
0.134
0.134
0.113
0.105
0.062
0.060
0.034
0.033
0.025
0.029
0.022
0.031
0.024
0.020
0.018
0.015
590
590
746
846
1202
1396
2028
2146
2858
2483
3122
2381
2941
3539
3864
4467
885
885
1118
1269
1803
2094
3043
3219
4286
3724
4683
3571
4412
5308
5796
6700
B41858C5187M***
B41858C5227M***
B41858C5337M***
B41858C5477M***
B41858C5827M***
B41858C5108M***
B41858C5158M***
B41858C5188M***
B41858D5228M***
B41858C5228M***
B41858D5278M***
B41858C5278M***
B41858C5338M***
B41858C5398M***
B41858C5478M***
B41858C5568M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for ∅ ≥ 10 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm)
003 = for crimped leads, blister (for ∅ ≥ 16 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 8 of 30
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 35 V DC
120
8 × 11.5
180 10 × 12.5
220 10 × 12.5
330 10 × 16
470 10 × 20
560 10 × 20
680 12.5 × 20
1000 12.5 × 25
1200 16 × 20
1500 12.5 × 40
1500 16 × 25
1800 16 × 31.5
1800 18 × 20
2200 18 × 25
2700 18 × 31.5
3300 18 × 35
4700 18 × 40
VR = 50 V DC
82
8 × 11.5
100
8 × 11.5
120 10 × 12.5
180 10 × 16
330 10 × 20
470 12.5 × 20
560 12.5 × 25
680 12.5 × 30
820 12.5 × 40
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
1.200
1.035
1.035
0.946
0.584
0.584
0.496
0.327
0.307
0.243
0.251
0.192
0.271
0.217
0.165
0.160
0.125
1.263
0.842
0.689
0.459
0.323
0.271
0.223
0.152
0.126
0.101
0.101
0.084
0.084
0.080
0.065
0.061
0.048
0.150
0.129
0.129
0.118
0.073
0.073
0.062
0.041
0.038
0.030
0.031
0.024
0.034
0.027
0.021
0.020
0.016
0.134
0.113
0.113
0.105
0.062
0.062
0.060
0.034
0.033
0.025
0.029
0.022
0.031
0.024
0.020
0.018
0.015
590
746
746
846
1202
1202
1396
2028
2146
2858
2483
3122
2381
2941
3539
3864
4467
885
1118
1118
1269
1803
1803
2094
3043
3219
4286
3724
4683
3571
4412
5308
5796
6700
B41858C7127M***
B41858C7187M***
B41858C7227M***
B41858C7337M***
B41858C7477M***
B41858C7567M***
B41858C7687M***
B41858C7108M***
B41858C7128M***
B41858D7158M***
B41858C7158M***
B41858D7188M***
B41858C7188M***
B41858C7228M***
B41858C7278M***
B41858C7338M***
B41858C7478M***
5.168
5.168
2.984
1.400
1.000
0.880
0.712
0.360
0.269
1.540
1.263
1.053
0.702
0.383
0.269
0.226
0.186
0.154
0.646
0.646
0.373
0.175
0.125
0.110
0.089
0.045
0.034
0.573
0.573
0.336
0.160
0.118
0.104
0.082
0.043
0.032
340
340
555
778
1030
1300
1490
2140
2799
510
510
833
1167
1545
1950
2235
3210
4199
B41858C6826M***
B41858C6107M***
B41858C6127M***
B41858C6187M***
B41858C6337M***
B41858C6477M***
B41858C6567M***
B41858C6687M***
B41858C6827M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for ∅ ≥ 10 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm)
003 = for crimped leads, blister (for ∅ ≥ 16 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 9 of 30
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
VR = 50 V DC
820 16 × 20
1000 16 × 31.5
1000 18 × 20
1500 18 × 25
1800 18 × 31.5
2200 18 × 35
2700 18 × 40
VR = 63 V DC
56
8 × 11.5
82 10 × 12.5
120 10 × 16
180 10 × 20
270 12.5 × 20
330 12.5 × 20
390 12.5 × 25
470 16 × 20
680 12.5 × 40
680 16 × 25
680 18 × 20
820 16 × 31.5
820 18 × 25
1200 18 × 31.5
1500 18 × 35
1800 18 × 40
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
0.401
0.260
0.477
0.382
0.300
0.268
0.210
0.154
0.126
0.126
0.084
0.070
0.069
0.065
0.050
0.032
0.048
0.038
0.030
0.027
0.021
0.046
0.030
0.044
0.036
0.028
0.024
0.020
1820
2653
1997
2417
2989
3320
3871
2730
3980
2995
3626
4483
4980
5807
B41858D6827M***
B41858C6108M***
B41858D6108M***
B41858C6158M***
B41858C6188M***
B41858C6228M***
B41858C6278M***
5.413
5.766
3.075
1.986
1.688
1.688
1.236
1.037
0.717
0.772
0.960
0.541
0.761
0.518
0.441
0.375
2.256
1.540
1.053
0.702
0.468
0.383
0.324
0.269
0.186
0.186
0.186
0.154
0.154
0.105
0.084
0.070
0.541
0.577
0.308
0.199
0.169
0.169
0.124
0.104
0.072
0.077
0.096
0.054
0.076
0.052
0.044
0.038
0.488
0.500
0.279
0.180
0.153
0.153
0.112
0.094
0.065
0.070
0.087
0.049
0.069
0.047
0.040
0.034
310
354
519
705
876
876
1118
1272
1785
1600
1427
2092
1735
2294
2592
2967
464
531
779
1058
1315
1315
1676
1907
2677
2400
2140
3138
2602
3441
3888
4450
B41858C8566M***
B41858C8826M***
B41858C8127M***
B41858C8187M***
B41858C8277M***
B41858C8337M***
B41858C8397M***
B41858C8477M***
B41858C8687M***
B41858D8687M***
B41858E8687M***
B41858C8827M***
B41858D8827M***
B41858C8128M***
B41858C8158M***
B41858C8188M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for ∅ ≥ 10 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm)
003 = for crimped leads, blister (for ∅ ≥ 16 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 10 of 30
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
ESRmax
10 kHz
40 °C
Ω
ESRmax
120 Hz
20 °C
Ω
VR = 80 V DC
33
8 × 11.5 12.219 3.828
39 10 × 12.5 9.813 3.239
56 10 × 16
6.542 2.256
82 10 × 20
4.606 1.540
150 12.5 × 20
3.048 0.842
180 12.5 × 25
2.038 0.702
270 12.5 × 30
1.732 0.468
270 16 × 20
1.313 0.468
330 16 × 25
0.985 0.383
390 12.5 × 40
1.314 0.324
390 18 × 20
1.260 0.324
470 16 × 31.5 0.973 0.269
470 18 × 25
1.008 0.269
680 18 × 31.5 0.720 0.186
820 18 × 35
0.679 0.154
1000 18 × 40
0.438 0.126
VR = 100 V DC
22
8 × 11.5 12.219 4.593
27 10 × 12.5 9.813 3.743
33 10 × 16
6.542 3.062
56 10 × 20
4.606 1.804
100 12.5 × 20
3.048 1.011
120 12.5 × 25
2.038 0.842
180 12.5 × 30
1.732 0.561
180 16 × 20
1.313 0.561
220 16 × 25
0.985 0.459
270 12.5 × 40
1.314 0.374
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
1.222
0.981
0.654
0.461
0.305
0.204
0.173
0.131
0.099
0.131
0.126
0.097
0.101
0.072
0.068
0.044
1.114
0.883
0.589
0.423
0.281
0.188
0.159
0.122
0.091
0.121
0.119
0.090
0.095
0.068
0.063
0.042
205
266
357
460
647
864
1009
1119
1402
1309
1220
1546
1477
1907
2061
2683
307
400
536
691
971
1296
1514
1678
2103
1963
1830
2319
2215
2861
3092
4025
B41858C0336M***
B41858C0396M***
B41858C0566M***
B41858C0826M***
B41858C0157M***
B41858C0187M***
B41858C0277M***
B41858D0277M***
B41858C0337M***
B41858C0397M***
B41858D0397M***
B41858C0477M***
B41858D0477M***
B41858C0687M***
B41858C0827M***
B41858C0108M***
1.222
0.981
0.654
0.461
0.305
0.204
0.173
0.131
0.099
0.131
1.114
0.883
0.589
0.423
0.281
0.188
0.159
0.122
0.091
0.121
205
266
357
460
647
864
1009
1119
1402
1309
307
400
536
691
971
1296
1514
1678
2103
1963
B41858C9226M***
B41858C9276M***
B41858C9336M***
B41858C9566M***
B41858C9107M***
B41858C9127M***
B41858C9187M***
B41858D9187M***
B41858C9227M***
B41858C9277M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for ∅ ≥ 10 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm)
003 = for crimped leads, blister (for ∅ ≥ 16 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 11 of 30
B41858
Low impedance 105 °C
Technical data and ordering codes
CR
120 Hz
20 °C
µF
Case
dimensions
d×l
mm
ESRmax
10 kHz
40 °C
Ω
VR = 100 V DC
270 18 × 20
330 16 × 31.5
330 18 × 25
390 18 × 31.5
560 18 × 35
680 18 × 40
1.260
0.973
1.008
0.720
0.679
0.438
ESRmax
120 Hz
20 °C
Ω
ESRmax
10 kHz
20 °C
Ω
Zmax
100 kHz
20 °C
Ω
IAC,R
100 kHz
105 °C
mA
IAC,max
Ordering code
100 kHz (composition see
85 °C
below)
mA
0.374
0.306
0.306
0.259
0.180
0.149
0.126
0.097
0.101
0.072
0.068
0.044
0.119
0.090
0.095
0.068
0.063
0.042
1220
1546
1477
1907
2061
2683
1830
2319
2215
2861
3092
4025
B41858D9277M***
B41858C9337M***
B41858D9337M***
B41858C9397M***
B41858C9567M***
B41858C9687M***
Composition of ordering code
*** = Version
000 = for standard leads, bulk
001 = for kinked leads, bulk (for ∅ ≥ 10 mm)
002 = for cut leads, bulk (for ∅ ≥ 10 mm)
003 = for crimped leads, blister (for ∅ ≥ 16 mm)
004 = for J leads, blister (from d × l = 10 × 12.5 mm to 18 × 35 mm)
008 = for taped leads, Ammo pack, lead spacing F = 5.0 mm (from d × l = 8 × 11.5 mm to 12.5 × 25 mm)
009 = for taped leads, Ammo pack, lead spacing F = 7.5 mm (from d × l = 16 × 20 mm to 18 × 31.5 mm)
012 = for bent 90° leads, blister (for ∅ 16 and 18 mm)
Please read Cautions and warnings and
Important notes at the end of this document.
Page 12 of 30
B41858
Low impedance 105 °C
Useful life
depending on ambient temperature TA under ripple current operating conditions1)
d = 8 mm
d ≥ 10 mm
1)
Refer to chapter "General technical information, 5.3 Calculation of useful life" for an explanation on how to interpret the useful life
graphs.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 13 of 30
B41858
Low impedance 105 °C
Frequency factor of permissible ripple current IAC versus frequency f
Please read Cautions and warnings and
Important notes at the end of this document.
Page 14 of 30
B41858
Low impedance 105 °C
Taping, packing and lead configurations
Taping
Single-ended capacitors are available taped in Ammo pack from diameter 5 to 18 mm as follows:
Lead spacing F = 2.5 mm (∅ d = 5 … 6.3 mm)
Lead spacing F = 3.5 mm (∅ d = 8 mm)
Lead spacing F = 5.0 mm (∅ d = 5 … 12.5 mm)
Lead spacing F = 7.5 mm (∅ d = 16 ... 18 mm).
Lead spacing 2.5 mm (∅ d = 5 ... 6.3 mm)
Last 3 digits of ordering code: 007
Dimensions in mm
∅d
5
F
H
W
W0
W1
W2
H0
P
P0
P1
I1
t
∆h
D0
2.5 18.5 18.0 5.5 9.0 1.5 16.0 12.7 12.7 5.1 1.0 0.7 1.0 4.0
6.3
Toler- +0.8
±0.75 ±0.5 min. ±0.5 max. ±0.5 ±1.0 ±0.2 ±0.5 max. ±0.2 max. ±0.2
ance 02
Please read Cautions and warnings and
Important notes at the end of this document.
Page 15 of 30
B41858
Low impedance 105 °C
Lead spacing 3.5 mm (∅ d = 8 mm)
Last 3 digits of ordering code: 006
Dimensions in mm
∅d
8
Tolerance
F
H
W
W0
W1
W2
P
P0
P1
I1
t
∆h
3.5
18.5
18.0
12.5
9.0
1.5
12.7
12.7
4.6
1.0
0.7
1.0
+0.8
02
1.0
±0.5
min.
±0.5
max. ±1.0
±0.2
±0.5
max. ±0.2
Please read Cautions and warnings and
Important notes at the end of this document.
Page 16 of 30
D0
4.0
max. ±0.2
B41858
Low impedance 105 °C
Lead spacing 5.0 mm (∅ d = 5 ... 8 mm)
Last 3 digits of ordering code: 008
Lead spacing 5.0 mm (∅ d = 10 ... 12.5 mm)
Last 3 digits of ordering code: 008
Dimensions in mm
∅d
5
6.3
F
H
W
W0
W1
W2
H0
P
P0
P1
I1
t
∆h
D0
5.0
18.5
18.0 5.5
9.0
1.5
16.0
12.7
12.7
3.85
1.0
0.7
1.0
4.0
16.0
12.7
12.7
3.85
18.0 12.5 9.0
1.5
12.7
12.7
3.85
1.0
0.7
1.0
4.0
15.0
15.0
5.0
±1.0
±0.2
±0.5
8
10
20.0
5.0
12.5
Toler- +0.8
ance 02
19.0
19.0
±0.75 ±0.5 min. ±0.5 max. ±0.5
Please read Cautions and warnings and
Important notes at the end of this document.
Page 17 of 30
max. ±0.2 max. ±0.2
B41858
Low impedance 105 °C
Lead spacing 7.5 mm (∅ d = 16 ...18 mm)
Last 3 digits of ordering code: 009
Dimensions in mm
∅d
16
F
H
W
7.5 18.5 18.0
18 *)
Toler0.5
±0.8
±0.5
ance
+0.75
W0
W1
W2
P
P0
P1
I1
t
∆P
∆h
D0
12.5
9.0
1.5
30.0
15.0
3.75
1.0
0.7
0
0
4.0
min.
±0.5
max. ±1.0
±0.2
±0.5
max. ±0.2 ±1.0 ±1.0 ±0.2
*) Available only for case dimensions 18 × 20, 18 × 25 and 18 × 31.5 mm
Please read Cautions and warnings and
Important notes at the end of this document.
Page 18 of 30
B41858
Low impedance 105 °C
Packing units and box dimensions
Ammo pack
Please read Cautions and warnings and
Important notes at the end of this document.
Case size
d×l
mm
Dimensions (mm)
Amax
Bmax
Cmax
5 × 11
345
55
240
2000
6.3 × 11
345
55
290
2000
8 × 11.5
345
55
240
1000
10 × 12.5
345
55
280
750
10 × 16
345
60
200
500
10 × 20
345
60
200
500
12.5 × 20
345
65
280
500
12.5 × 25
345
65
280
500
12.5 × 25
345
65
280
500
12.5 × 30
345
65
275
500
16 × 20
315
65
275
300
16 × 25
315
65
275
300
16 × 31.5
315
65
275
300
18 × 20
315
65
275
250
18 × 25
315
65
275
250
18 × 31.5
315
65
275
250
Page 19 of 30
Packing
units
pcs.
B41858
Low impedance 105 °C
Kinked or cut leads
Single-ended capacitors are available with kinked or cut leads. Other lead configurations also
available upon request.
Kinked leads
Last 3 digits of ordering code: 001
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 20 of 30
Dimensions (mm)
a ±0.5
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
12.5 × 30
5.0
12.5 × 35
5.0
12.5 × 40
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
20 × 20
10.0
20 × 25
10.0
20 × 40
10.0
22 × 30
10.0
22 × 35
10.0
22 × 40
10.0
B41858
Low impedance 105 °C
Cut leads
Last 3 digits of ordering code: 002
With stand-off rubber seal
Case size
d × l (mm)
With flat rubber seal
Please read Cautions and warnings and
Important notes at the end of this document.
Page 21 of 30
Dimensions (mm)
a ±0.5
10 × 12.5
5.0
10 × 16
5.0
10 × 20
5.0
12.5 × 20
5.0
12.5 × 25
5.0
12.5 × 30
5.0
12.5 × 35
5.0
12.5 × 40
5.0
16 × 20
7.5
16 × 25
7.5
16 × 31.5
7.5
18 × 20
7.5
18 × 25
7.5
18 × 31.5
7.5
18 × 35
7.5
18 × 40
7.5
20 × 20
10.0
20 × 25
10.0
20 × 40
10.0
B41858
Low impedance 105 °C
PAPR leads (Protection Against Polarity Reversal)
These lead configurations ensure correct placement of the capacitor on the PCB with regard to
polarity. PAPR leads are available for diameters from 10 mm up to 20 mm.
There are three configurations available: Crimped leads, J leads, bent 90° leads
Crimped leads
Last 3 digits of ordering code: 003
With stand-off rubber seal
With flat rubber seal
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
B ±0.2
C ±0.5
D ±0.1
E ±0.1
16 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
16 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.05
18 × 20
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 25
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 31.5
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 35
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
18 × 40
1.5
3.0
1.3
0.3
7.5
0.8 ±0.1
20 × 20
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 25
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
20 × 40
1.5
3.0
1.6
0.3
10.0
1.0 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 22 of 30
a ±0.5
∅b
B41858
Low impedance 105 °C
J leads
Last 3 digits of ordering code: 004
Suggestion for PCB hole diameter
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
J ±0.2
10 × 12.5
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 16
3.2
0.7
1.2
5.0
0.6 ±0.05
10 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 20
3.2
0.7
1.2
5.0
0.6 ±0.05
12.5 × 25
3.2
0.7
1.2
5.0
0.6 ±0.05
16 × 20
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 25
3.5
0.7
1.6
7.5
0.8 ±0.05
16 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.05
18 × 20
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 25
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 31.5
3.5
0.7
1.6
7.5
0.8 ±0.1
18 × 35
3.5
0.7
1.6
7.5
0.8 ±0.1
Please read Cautions and warnings and
Important notes at the end of this document.
Page 23 of 30
a ±0.5
∅b
B41858
Low impedance 105 °C
Bent 90° leads for horizontal mounting pinning
Last 3 digits of ordering code: 012
Case size
d × l (mm)
Dimensions (mm)
C ±0.5
E ±0.5
F ±0.5
a ±0.5
∅b
16 × 20
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 25
4.0
4.0
12.0
7.5
0.8 ±0.05
16 × 31.5
4.0
4.0
12.0
7.5
0.8 ±0.05
18 × 20
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 25
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 31.5
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 35
4.0
4.0
13.0
7.5
0.8 ±0.1
18 × 40
4.0
4.0
13.0
7.5
0.8 ±0.1
Bent leads for diameter 12.5 mm available upon request.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 24 of 30
B41858
Low impedance 105 °C
Overview of packing units and code numbers for case sizes 5 × 11 ... 16 × 31.5
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
5 × 11
2000
6.3 × 11
2500
2000
8 × 11.5
1000
1000
10 × 12.5
1000
750
10 × 16
100
500
1000
10 × 20
500
500
500
500
12.5 × 20
350
500
350
350
12.5 × 25
250
500
500
500
12.5 × 30
200
500
175
175
12.5 × 35
175
-
175
175
12.5 × 40
175
-
175
175
16 × 20
250
300
200
200
16 × 25
250
300
200
16 × 31.5
200
300
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code
006
007
008
009
1)
pcs.
Kinked
leads,
bulk
pcs.
Cut
Crimped J leads
leads, leads
bulk
pcs.
pcs.
pcs.
2000
F (mm) d (mm)
3.5
2.5
5
7.5
1000
675
675
500
300
1)
225
1)
180
1)
150
1)
150
1)
200
200
120
200
200
200
120
250
250
344
344
120
001
002
003
004
012
8
5...6.3
5...12.5
16...18
Available upon request
Please read Cautions and warnings and
Important notes at the end of this document.
Bent 90°
leads,
blister
pcs.
Page 25 of 30
B41858
Low impedance 105 °C
Overview of packing units and code numbers for case sizes 18 × 20 ... 25 × 40
PAPR
Case size
d×l
Taped,
Ammo pack
mm
Standard,
bulk
pcs.
pcs.
Kinked
leads,
bulk
pcs.
Cut
Crimped J leads
leads, leads
bulk
pcs.
pcs.
pcs.
Bent 90°
leads,
blister
pcs.
18 × 20
175
18 × 25
150
250
175
175
200
200
120
250
150
150
200
200
18 × 31.5
120
100
250
100
100
150
150
120
18 × 35
100
100
100
150
150
150
18 × 40
125
100
100
120
72
20 × 20
125
125
125
200
20 × 25
125
125
125
200
20 × 30
100
100
100
120
20 × 35
100
100
100
120
20 × 40
100
100
100
120
22 × 30
80
100
100
22 × 35
80
100
100
22 × 40
80
100
100
25 × 40
40
100
The last three
digits of the
complete
ordering code
state the lead
configuration
000
Code
007
008
009
001
002
Please read Cautions and warnings and
Important notes at the end of this document.
F (mm) d (mm)
2.5
5
7.5
4...6.3
6.3...12.5
16...18
Page 26 of 30
003
004
012
B41858
Low impedance 105 °C
Cautions and warnings
Personal safety
The electrolytes used by EPCOS have not only been optimized with a view to the intended
application, but also with regard to health and environmental compatibility. They do not contain
any solvents that are detrimental to health, e.g. dimethyl formamide (DMF) or dimethyl acetamide
(DMAC).
Furthermore, part of the high-voltage electrolytes used by EPCOS are self-extinguishing. They
contain flame-retarding substances which will quickly extinguish any flame that may have been
ignited.
As far as possible, EPCOS does not use any dangerous chemicals or compounds to produce
operating electrolytes. However, in exceptional cases, such materials must be used in order to
achieve specific physical and electrical properties because no safe substitute materials are
currently known. However, the amount of dangerous materials used in our products has been
limited to an absolute minimum. Nevertheless, the following rules should be observed when
handling Al electrolytic capacitors:
Any escaping electrolyte should not come into contact with eyes or skin.
If electrolyte does come into contact with the skin, wash the affected parts immediately with
running water. If the eyes are affected, rinse them for 10 minutes with plenty of water. If
symptoms persist, seek medical treatment.
Avoid breathing in electrolyte vapor or mists. Workplaces and other affected areas should be
well ventilated. Clothing that has been contaminated by electrolyte must be changed and
rinsed in water.
Please read Cautions and warnings and
Important notes at the end of this document.
Page 27 of 30
B41858
Low impedance 105 °C
Product safety
The table below summarize the safety instructions that must be observed without fail. A detailed
description can be found in the relevant sections of chapter "General technical information".
Topic
Safety information
Polarity
Make sure that polar capacitors are connected
with the right polarity.
Reverse voltage
Voltages polarity classes should be prevented by
connecting a diode.
Do not exceed the upper category temperatur.
Upper category
temperature
Maintenance
Mounting
position of screw
terminal capacitors
Mounting of
single-ended
capacitors
Robustness of
terminals
Soldering
Make periodic inspections of the capacitors.
Before the inspection, make sure that the power
supply is turned off and carefully discharge the
electricity of the capacitors.
Do not apply any mechanical stress to the
capacitor terminals.
Do not mount the capacitor with the terminals
(safety vent) upside down.
Reference
Chapter "General
technical information"
1
"Basic construction of
aluminum electrolytic
capacitors"
3.1.6
"Reverse voltage"
7.2
"Maximum permissible
operating temperature"
10
"Maintenance"
11.1.
"Mounting positions of
capacitors with screw
terminals"
The internal structure of single-ended capacitors 11.4
might be damaged if excessive force is applied to "Mounting
the lead wires.
considerations for
Avoid any compressive, tensile or flexural stress. single-ended capacitors"
Do not move the capacitor after soldering to PC
board.
Do not pick up the PC board by the soldered
capacitor.
Do not insert the capacitor on the PC board with a
hole space different to the lead space specified.
The following maximum tightening torques must
11.3
not be exceeded when connecting screw
"Mounting torques"
terminals:
M5: 2 Nm
M6: 2.5 Nm
Do not exceed the specified time or temperature 11.5
limits during soldering.
"Soldering"
Please read Cautions and warnings and
Important notes at the end of this document.
Page 28 of 30
B41858
Low impedance 105 °C
Topic
Soldering,
cleaning agents
Passive
flammability
Active
flammability
Safety information
Reference
Chapter "General
technical information"
Do not allow halogenated hydrocarbons to come 11.6
into contact with aluminum electrolytic capacitors. "Cleaning agents"
Avoid external energy, such as fire or electricity.
8.1
"Passive flammability"
Avoid overload of the capacitors.
8.2
"Active flammability"
Breakdown strength Do not damage the insulating sleeve, especially
of insulating
when ring clips are used for mounting.
sleeves
Please read Cautions and warnings and
Important notes at the end of this document.
Page 29 of 30
Reference
Chapter "Capacitors
with screw terminals"
"Screw terminals accessories"
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out
in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications
in which the malfunction or failure of a passive electronic component could endanger human
life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured
by means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order. We also
reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, EPCOS-JONES, BAOKE, Alu-X, CeraDiode, CSSP, MLSC,
PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K,
UltraCap, WindCap are trademarks registered or pending in Europe and in other countries.
Further information will be found on the Internet at www.epcos.com/trademarks.
Page 30 of 30