EPCOS B4236

SAW Components
Preliminary Data B4236
SAW Components
B4236
Low-Loss ’2 in 1’ Filter for Mobile Communication
769,0/809,5 MHz
Preliminary Data
Ceramic package QCC8E
Features
0,75
2
3
0,75
4
8
1
0,5
7
6
0,5
1,0
Low-loss ‘2 in 1’ RF filter for Trunked Radio
Device with two integrated Rx filters
Low amplitude ripple
Usable passband filter 1: 31,0 MHz
Usable passband filter 2: 14,0 MHz
No matching network required for operation at
50 Ω
■ Package for Surface Mounted
Technology (SMT)
■ RoHS Compliant
■
■
■
■
■
■
bottom view
5
0,98
Terminals
side view
2,5
1,0 1,0
top view
■ Ni, gold-plated
3,0
Dimensions in mm, approx. weight 27mg
Pin configuration
1
7
3
5
2,6
4,8
Input (filter 1)
Output (filter 1)
Input (filter 2)
Output (filter 2)
Ground
Case ground
Type
Ordering code
B4236
B39811-B4236-H410
Marking and Package
according to
C61157-A7-A92
Packing
according to
F61074-V8174-Z000
Electrostatic Sensitive Device (ESD)
Maximum ratings
Operable temperature range
Storage temperature range
DC voltage
ESD voltage
Source power (cw)
T
Tstg
VDC
V*ESD
PS
– 40 / + 85
– 40 / + 85
5
100
15
˚C
˚C
V
V
dBm
Machine Model, 10 pulses
source and load impedance 50 Ω
*-acc. to JESD22-A115A (Machine Model), 10 negative & 10 positive pulses
2
Oct 14, 2005
SAW Components
B4236
Low-Loss ’2 in 1’ Filter for Mobile Communication
769,0/809,5 MHz
Preliminary Data
Characteristics filter 1
T = 25 ± 2 ˚C
ZS = 50 Ω
ZL = 50 Ω
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
fN
Nominal frequency
Maximum insertion attenuation
794,0 ... 825,0
min.
typ.
max.
—
809,5
—
—
2,3
2,8
dB
—
0,9
1,4
dB
—
27,0
50,0
ns
—
dB
MHz
αmax
MHz
∆α
Amplitude ripple (p-p)
794,0 ... 825,0
MHz
∆τ
Group delay ripple (p-p)
794,0 ... 825,0
MHz
Return loss (Input and Output)
794,0 ... 825,0
MHz
8,0
9,0
αabs
Absolute attenuation
0,0
851,0
1564,5
2326,5
... 777,0
...1564,5
...1594,5
...2371,5
MHz
MHz
MHz
MHz
TCf
Temperature coefficient of frequency
3
20
20
30
36
28
39
43
41
—
—
—
—
dB
dB
dB
dB
—
– 36
—
ppm/K
Oct 14, 2005
SAW Components
B4236
Low-Loss ’2 in 1’ Filter for Mobile Communication
769,0/809,5 MHz
Preliminary Data
Characteristics filter 1
T = -30 .. +70 ˚C
ZS = 50 Ω
ZL = 50 Ω
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
fN
Nominal frequency
Maximum insertion attenuation
794,0 ... 825,0
min.
typ.
max.
—
809,5
—
—
2,3
3,3
dB
—
0,9
1,9
dB
—
40,0
75,0
ns
—
dB
MHz
αmax
MHz
∆α
Amplitude ripple (p-p)
794,0 ... 825,0
MHz
∆τ
Group delay ripple (p-p)
794,0 ... 825,0
MHz
Return loss (Input and Output)
794,0 ... 825,0
MHz
8,0
9,0
αabs
Absolute attenuation
0,0
851,0
1564,5
2326,5
... 777,0
...1564,5
...1594,5
...2371,5
MHz
MHz
MHz
MHz
TCf
Temperature coefficient of frequency
4
20
20
30
36
27
37
43
41
—
—
—
—
dB
dB
dB
dB
—
– 36
—
ppm/K
Oct 14, 2005
SAW Components
B4236
Low-Loss ’2 in 1’ Filter for Mobile Communication
Preliminary Data
Transfer function filter 1 (narrow band)
Transfer function filter 1 (wide band)
5
Oct 14, 2005
769,0/809,5 MHz
SAW Components
B4236
Low-Loss ’2 in 1’ Filter for Mobile Communication
769,0/809,5 MHz
Preliminary Data
Characteristics filter 2
T = 25 ± 2 ˚C
ZS = 50 Ω
ZL = 50 Ω
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
fN
Nominal frequency
Maximum insertion attenuation
762,0 ... 776,0
min.
typ.
max.
—
769,0
—
—
1,7
2,4
dB
—
0,4
1,0
dB
MHz
αmax
MHz
∆α
Amplitude ripple (p-p)
762,0 ... 776,0
MHz
∆τ
Group delay ripple (p-p)
762,0 ... 776,0
MHz
—
22,0
50,0
ns
Return loss (Input and Output)
762,0 ... 776,0
MHz
12,0
13,5
—
dB
57
50
30
20
9
25
30
50
47
42
30
30
60
60
58
52
22
36
52
56
54
52
42
39
—
—
—
—
—
—
—
—
—
—
—
—
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
—
– 36
—
ppm/K
αabs
Absolute attenuation
0,0
431,0
604,0
690,0
733,0
804,0
847,0
892,7
910,7
995,3
1524,0
2286,0
... 431,0
... 604,0
... 690,0
... 733,0
... 752,0
... 847,0
... 892,7
... 910,7
... 995,3
...1121,0
...1554,0
...2331,0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
TCf
Temperature coefficient of frequency
6
Oct 14, 2005
SAW Components
B4236
Low-Loss ’2 in 1’ Filter for Mobile Communication
769,0/809,5 MHz
Preliminary Data
Characteristics filter 2
T = -30 .. +70 ˚C
ZS = 50 Ω
ZL = 50 Ω
Operating temperature range:
Terminating source impedance:
Terminating load impedance:
fN
Nominal frequency
Maximum insertion attenuation
762,0 ... 776,0
min.
typ.
max.
—
769,0
—
—
1,8
2,6
dB
—
0,5
1,0
dB
MHz
αmax
MHz
∆α
Amplitude ripple (p-p)
762,0 ... 776,0
MHz
∆τ
Group delay ripple (p-p)
762,0 ... 776,0
MHz
—
30,0
50,0
ns
Return loss (Input and Output)
762,0 ... 776,0
MHz
12,0
13,5
—
dB
57
50
30
20
9
25
30
50
47
42
30
30
60
60
58
52
18
36
52
56
54
52
42
39
—
—
—
—
—
—
—
—
—
—
—
—
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
—
– 36
—
ppm/K
αabs
Absolute attenuation
0,0
431,0
604,0
690,0
733,0
804,0
847,0
892,7
910,7
995,3
1524,0
2286,0
... 431,0
... 604,0
... 690,0
... 733,0
... 752,0
... 847,0
... 892,7
... 910,7
... 995,3
...1121,0
...1554,0
...2331,0
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
MHz
TCf
Temperature coefficient of frequency
7
Oct 14, 2005
SAW Components
B4236
Low-Loss ’2 in 1’ Filter for Mobile Communication
Preliminary Data
Transfer function filter 2 (narrow band)
Transfer function filter 2 (wide band)
8
Oct 14, 2005
769,0/809,5 MHz
SAW Components
B4236
Low-Loss ’2 in 1’ Filter for Mobile Communication
769,0/809,5 MHz
Preliminary Data
Published by EPCOS AG
Surface Acoustic Wave Components Division, SAW COM WT PD
P.O. Box 80 17 09, D-81617 München
 EPCOS AG 2005. All Rights Reserved. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited.
The information contained in this brochure describes the type of component and shall not be considered as guaranteed characteristics. Purchase orders are subject to the General Conditions for
the Supply of Products and Services of the Electrical and Electronics Industry recommended by the
ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed.
This brochure replaces the previous edition.
For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or
the international Representatives.
Due to technical requirements components may contain dangerous substances. For information on
the type in question please also contact one of our Sales Offices.
9
Oct 14, 2005