Motor Starting B59*** Metallized Disks A 19*, A 314, A 5** Applications ■ Time delay in turning off the auxiliary winding of single-phase AC motors (e.g. refrigerator compressors) ■ Type A 314 suitable for airconditioning systems applications Features ■ ■ ■ ■ ■ ■ Metallization: CrNi (sputtered) + Ag (screen-printed), except A 314 (screen-printed Ag) Excellent long-term reliability Suitable for clamp contacting UL approval to UL 1434 (file number E69802), except A 502 and A 196 VDE approval (license number 87406 E), except A 524 and A 314 CSA approval for A 506 (certificate No. 1109600) Options ■ Other dimensions and ratings on request Delivery mode ■ Bulk Dimensional drawing A 19*, A 5** A 314 Cr/Ni Ag r 0,9±0,6 b b s Kontaktierung Termination Termination TPT0657-3 s TPT0449-Z Dimensions (mm) V N = 230 Vrms Type b A 502 19,5 + 0,5 A 501 19,5 + 0,5 A 550 16,0 ± 0,5 A 524 19,5 ± 0,5 A 549 16,0 ± 0,5 A 544 17,5 ± 0,5 A 192 19,5 ± 0,5 s 2,5 ± 0,2 2,5 ± 0,2 2,5 ± 0,2 2,5 ± 0,2 2,5 ± 0,2 2,5 ± 0,2 2,5 ± 0,2 V N = 230 Vrms Type b A 196 19,5 ± 0,5 A 197 19,5 ± 0,5 A 314 20,0 + 0,2/– 0,8 V N = 120 Vrms Type b A 508 17,5 ± 0,5 A 506 17,5 ± 0,5 154 10/02 s 3,2 ± 0,2 3,2 ± 0,2 5,0 ± 0,25 s 2,5 ± 0,2 2,5 ± 0,2 Motor Starting B59*** Metallized Disks A 19*, A 314, A 5** General technical data Switching cycles Operating temperature range (V = 0) (V = Vmax) > 100000 + 5/+ 80 + 5/+ 80 N Top Top °C °C Electrical specifications and ordering codes Type Imax A V N = 230 Vrms A 502 4 A 501 6 A 550 6 A 524 7 A 549 7 A 544 8 A 192 8 A 196 8 A 197 9 A 314 9 V N = 120 Vrms A 508 10 A 506 12 Ordering code V R N ± ∆R N Ir2) (VPTC ≤ 2,5 V) Ω mA 0,55 0,45 0,30 0,55 0,35 0,35 0,35 0,50 0,30 0,35 > 750 > 700 > 700 > 600 > 650 > 650 > 650 > 700 > 700 > 800 47 ± 30 % 33 ± 20 % 33 ± 20 % 22 ± 20 % 22 ± 20 % 20 ± 20 % 25 + 15/– 20 % 15 ± 30 % 33 ± 30 % 38 ± 30 % 8 8 7 10 8 12 10 10 8 10 B59502A0120A020 B59501A0135A020 B59550A0135A020 B59524A0135A020 B59549A0135A020 B59544A0120A020 B59192A0120A020 B59196A0120A020 B59197A0120B020 B59314A0120B0103) 0,55 0,45 > 360 > 360 4,7 ± 20 % 4,7 ± 20 % 17 16 B59508A0135A020 B59506A0120A020 V max TRef Tsurf tS1) VBD V °C °C s 400 355 355 300 300 320 325 350 350 400 120 135 135 135 135 120 120 120 120 120 180 190 190 190 190 180 180 180 180 190 180 180 135 120 190 180 1) Measured at V = Vmax and I = 0,8 · Imax 2) Measured with PTC thermistor mounted in standard EPCOS motor start housing 3) Type A 314 suitable for airconditioning systems applications 155 10/02 Motor Starting B59*** Metallized Disks A 19*, A 314, A 5** Reliability data Test 1) Standard Test conditions | ∆R25 /R25 | Switching test at room temperature IEC 60738-1 V max; R S Room temperature Number of cycles: 10000 < 25% Life test at V max /Top IEC 60738-1 Storage at V max /Top for t : 1000 h < 25% Damp heat IEC 60068-2-3 Storage at 40 °C Relative humidity: 93% Duration: 56 days < 20% Rapid change of temperature in air IEC 60068-2-14, Test N a – 25 °C, 125 °C Number of cycles: 5 t : 30 min < 20% Vibration IEC 60068-2-6, Test FC f = 10–55–10 Hz h = 0,75 mm (respectively 10 g) t: 3 · 2 h < 20% Bump IEC 60068-2-27 Pulse shape: half-sine a : = 40 g Pulse duration: 6 ms; 6 · 4000 pulses < 20% Climatic sequence IEC 60068-2-30 Dry heat: T = 125 °C, t : 16 h Damp heat first cycle Cold: T = – 25 °C, t : 2 h Damp heat 5 cycles < 25% 1) All tests with PTC disk mounted in EPCOS housing 156 10/02 Herausgegeben von EPCOS AG Unternehmenskommunikation, Postfach 80 17 09, 81617 München, DEUTSCHLAND ++49 89 636 09, FAX (0 89) 636-2 26 89 ( EPCOS AG 2002. Vervielfältigung, Veröffentlichung, Verbreitung und Verwertung dieser Broschüre und ihres Inhalts ohne ausdrückliche Genehmigung der EPCOS AG nicht gestattet. Bestellungen unterliegen den vom ZVEI empfohlenen Allgemeinen Lieferbedingungen für Erzeugnisse und Leistungen der Elektroindustrie, soweit nichts anderes vereinbart wird. Diese Broschüre ersetzt die vorige Ausgabe. Fragen über Technik, Preise und Liefermöglichkeiten richten Sie bitte an den Ihnen nächstgelegenen Vertrieb der EPCOS AG oder an unsere Vertriebsgesellschaften im Ausland. Bauelemente können aufgrund technischer Erfordernisse Gefahrstoffe enthalten. Auskünfte darüber bitten wir unter Angabe des betreffenden Typs ebenfalls über die zuständige Vertriebsgesellschaft einzuholen. Published by EPCOS AG Corporate Communications, P.O. Box 80 17 09, 81617 Munich, GERMANY ++49 89 636 09, FAX (0 89) 636-2 26 89 ( EPCOS AG 2002. Reproduction, publication and dissemination of this brochure and the information contained therein without EPCOS’ prior express consent is prohibited. Purchase orders are subject to the General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry recommended by the ZVEI (German Electrical and Electronic Manufacturers’ Association), unless otherwise agreed. This brochure replaces the previous edition. For questions on technology, prices and delivery please contact the Sales Offices of EPCOS AG or the international Representatives. Due to technical requirements components may contain dangerous substances. For information on the type in question please also contact one of our Sales Offices.