Chokes and inductors VHF chokes Series/Type: B82131 ... B82134 Date: November 2005 %BUB4IFFU © EPCOS AG 2005. Reproduction, publication and dissemination of this document and the information contained therein without EPCOS’ prior express consent is prohibited. VHF chokes B82131 ... B82134 Carbonyl iron core Rated voltage 500 VAC/DC Rated current 0.15 to 6 A Rated inductance 1 to 420 NH Construction ■ Cylinder core of carbonyl iron ■ Winding: single-layer, enamel copper wire ■ Polyester insulating sleeve Features ■ High resonant frequency ■ RoHS-compatible1) Applications ■ RF blocking and filtering ■ Interference suppression in small appliances ■ Decoupling in telecommunications and entertainment electronics Marking LR and IR in clear text Delivery mode Taped and reeled (for packing and packing units see page 6). Dimensional drawing 73 _ 1 k max. *) Tolerance over 10 spacings ± 2 mm IND0145-U 1.2 max. *) *) e min. 10±0.5 10±0.5 d max. 9±0.5 ø0.8 max. IND0144-Z-E Lead spacing e min (mm) Type 17.5 22.5 27.5 32.5 B82131 B82132 B82133 B82134 1) RoHS-compatible is defined as compatible with the following documents: DIRECTIVE 2002/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 13 February 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment COM (2004) 606 final Proposal for a COUNCIL DECISION amending Directive 2002/95/EC of the European Parliament and of the Council for the purposes of establishing the maximum concentration values for certain hazardous substances in electrical and electronic equipment. Please read the Important notes at the end of this document. 2 11/05 VHF chokes B82131 ... B82134 Carbonyl iron core General technical data Test voltage Vtest 2500 VAC, 1 min Rated inductance LR Measuring frequency:L ≤ 10 μH = 1 MHz 10 μH < L ≤ 1000 μH = 100 kHz Inductance tolerance ±20% Rated current IR Referred to 60 °C ambient temperature, for derating see below Inductance decrease ΔL/L0 ≤10% (referred to initial value) at DC load IR at 20 °C DC resistance Rtyp Typical value, measured at 20 °C ambient temperature Resonance frequency fres, min Typical value, measured with Scalar Network Analyzer ZAS from Rohde & Schwarz Climatic category (IEC 60068-1) 55/125/56 (–55 °C/+125 °C/56 days damp heat test) Current derating Iop/IR versus ambient temperature TA (rated temperature TR = 60 °C) SSB0087-Q-E 1.2 I op IR 1.0 0.8 0.6 0.4 0.2 0 Mounting information Please read the Important notes at the end of this document. 0 20 40 60 80 100 ˚C 140 TA When bending the leads, take care that the bending point is at least 3 mm apart from the face ends of the core and that the start-of-winding-areas are not subjected to any mechanical stress. 3 11/05 VHF chokes B82131 ... B82134 Carbonyl iron core Characteristics and ordering codes IR A 0.15 0.3 0.4 0.7 1.5 2 3 4 6 LR μH Rtyp Ω fres MHz Dimensions (mm) dmax l max kmax emin Approx. Ordering code weight g 80 11 22 5 14 15.4 17.5 0.8 B82131A5151M000 160 17 20 5.5 19 20.4 22.5 0.9 B82132A5151M000 350 21 11 7.5 24 25.4 27.5 2.3 B82133A5151M000 420 19 12 7.5 29 30.4 32.5 2.6 B82134A5151M000 B82131A5301M000 40 4.1 31 5 14 15.4 17.5 0.8 70 5.7 29 5.5 19 20.4 22.5 0.9 B82132A5301M000 160 6.5 16 7.5 24 25.4 27.5 2.2 B82133A5301M000 210 6.4 18 7.5 29 30.4 32.5 2.8 B82134A5301M000 27 2.0 40 5 14 15.4 17.5 0.8 B82131A5401M000 50 3.0 37 5.5 19 20.4 22.5 1.0 B82132A5401M000 130 4.8 18 7.5 24 25.4 27.5 2.8 B82133A5401M000 150 3.5 18 7.5 29 30.4 32.5 2.8 B82134A5401M000 14 0.76 53 5 14 15.4 17.5 0.8 B82131A5701M000 23 0.73 55 5.5 19 20.4 22.5 1.0 B82132A5701M000 55 1.20 26 7.5 24 25.4 27.5 2.4 B82133A5701M000 60 0.77 34 7.5 29 30.4 32.5 3.0 B82134A5701M000 6 0.19 84 5 14 15.4 17.5 0.8 B82131A5152M000 8 0.16 90 5.5 19 20.4 22.5 1.1 B82132A5152M000 25 0.32 40 7.5 24 25.4 27.5 2.5 B82133A5152M000 30 0.30 44 3 0.09 113 7.5 29 30.4 32.5 3.2 B82134A5152M000 5 14 15.4 17.5 0.8 B82131A5202M000 6 0.11 108 5.5 19 20.4 22.5 1.1 B82132A5202M000 14 0.13 57 7.5 24 25.4 27.5 2.8 B82133A5202M000 20 0.15 59 7.5 29 30.4 32.5 3.3 B82134A5202M000 2 0.038 147 5 14 15.4 17.5 1.0 B82131A5302M000 3 0.035 151 5.5 19 20.4 22.5 1.2 B82132A5302M000 10 0.077 69 7.5 24 25.4 27.5 2.9 B82133A5302M000 12 0.090 75 7.5 29 30.4 32.5 3.5 B82134A5302M000 1 0.014 199 5 14 15.4 17.5 1.1 B82131A5402M000 2 0.020 186 5.5 19 20.4 22.5 1.4 B82132A5402M000 5 0.034 87 7.5 24 25.4 27.5 3.0 B82133A5402M000 7 0.033 94 7.5 29 30.4 32.5 4.3 B82134A5402M000 1 0.010 243 5.5 19 20.4 22.5 1.4 B82132A5602M000 3 0.019 108 7.5 24 25.4 27.5 3.2 B82133A5602M000 Please read the Important notes at the end of this document. 4 11/05 VHF chokes B82131 ... B82134 Carbonyl iron core Impedance |Z | versus frequency f measured as per VDE 0565-2 (typical values) B82131A5***M000 B82132A5***M000 IND0146-1 10 6 Ω |Z | 10 6 B82131 Ω |Z | 10 5 _ A5151 _ A5301 _ A5401 10 4 10 3 10 2 10 2 _ A5701 _ A5152 _ A5202 _ A5302 _ A5402 10 1 10 0 6 10 10 7 10 8 10 0 6 10 Hz 10 9 f IND0148-6 10 8 Hz 10 9 f IND0149-9 10 6 B82133 Ω |Z | 5 10 4 B82134 10 5 10 4 10 3 10 3 _ A5151 _ A5301 _ A5401 _ A5701 _ A5152 _ A5202 _ A5302 _ A5402 _ A5602 10 2 10 1 10 0 6 10 10 7 B82134A5***M000 10 6 10 _ A5701 _ A5152 _ A5202 _ A5302 _ A5402 _ A5602 10 1 B82133A5***M000 Ω _ A5151 _ A5301 _ A5401 10 5 10 4 10 3 |Z | IND0147-5 B82132 10 7 10 8 _ A5151 _ A5301 _ A5401 _ A5701 _ A5152 _ A5202 _ A5302 _ A5402 10 2 10 1 10 0 6 10 Hz 10 9 f Please read the Important notes at the end of this document. 5 11/05 10 7 10 8 Hz 10 9 f VHF chokes B82131 ... B82134 Carbonyl iron core Packing 30 ø133 ø30.5±0.15 ø360 _ 1 ø126+1 Reel packing for B82131 ... B82134 30 95+1 Label Etikett 107 max. IND0451-4 Packing units Type Pieces/reel B82131 2000 B82132 2000 B82133 1000 B82134 1000 Please read the Important notes at the end of this document. 6 11/05 Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, CeraDiode, CSSP, PhaseCap, PhaseMod, SilverCap, SIFI, SIMID, SIKOREL, SIOV, SIP5D, SIP5K, TOPcap, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 7 11/05