GOLLEDGE HCD300

5V OCXO Low profile
HCD300 & HCD301
Specifications
HCD300: Sine output
HCD301: HCMOS / TTL compatible output
Product
Parameters
HCD301
5.0 ~ 20.0MHz
쮿
쮿
Ageing per day (at despatch):
< ±1x10-8
< ±5x10-9
왏
쮿
왏
쮿
Frequency stability:
±5x10-7 per year max
±5x10-8 per 5% change in VDD
쮿
쮿
쮿
쮿
< ±1x10-7
< ±5x10-8
왏
쮿
왏
쮿
M
N
Operating temperature range:
0 to +50°C
-20 to +60°C
-20 to +70°C
왏
쮿
왏
왏
쮿
왏
A
D
F
Storage temperature range:
-40 to +90°C
쮿
쮿
Frequency range:
36.10 (max)
27.20 (max)
15.00
(max)
0.50
0.80Ø
5.00
17.80
Temperature stability:
15.00
25.40
3
PIN
4
8.90
2
8.90
1
5
CONNECTION
1
Freq adjustment
2
Ref. voltage out
3
Supply
4
RF output
5
Ground & case
BOTTOM VIEW
Scale 1:1
«
«
«
«
«
Output waveform:
Sine wave, 1.5V p-p ±0.5V into 50⏲
HCMOS / TTL compatible
Frequency adjustment:
±5x10-6 typ (10MHz), +0.5 to +4.0V
(sufficient for 10 years ageing min)
Stabilised +4.0V supply provided
Features
Temperature stability down to 50ppb
Single 5V oven & oscillator supply
Low profile compact package
Standard European IEC CO-08 pin-out
Custom options available
Standard Models
The table shows the most common models. In most cases
selecting one of these models will ensure the best combination of price / performance and availability.
5.0MHz
10.0MHz
5.0MHz
10.0MHz
13.0MHz
Specification
Ageing
per day
HCD300/BNDL
HCD300/BNDL
HCD301/BNDL
HCD301/BNDL
HCD301/BNDL
±5x10-9
±5x10-9
±5x10-9
±5x10-9
±5x10-9
Temperature
stability
±5x10-8 -20+60°C
±5x10-8 -20+60°C
±5x10-8 -20+60°C
±5x10-8 -20+60°C
±5x10-8 -20+60°C
A
B
쮿
쮿
Supply voltage (VDD):
+5.0V (±0.25V)
쮿
쮿
Power consumption:
4.5W max at switch on
< 1.0W typ when stabilised at 25°C
쮿
쮿
쮿
쮿
Warm up:
±5x10-8 after 10mins at +25°C
쮿
쮿
Phase noise (@ 10.0MHz):
< -105dBc/Hz @ 10Hz
< -125dBc/Hz @ 100Hz
< -145dBc/Hz @ 1kHz
< -150dBc/Hz @ 10kHz
< -150dBc/Hz @ 50kHz
쮿
쮿
쮿
쮿
쮿
쮿
쮿
쮿
쮿
쮿
IEC 68-2-27 Test Ea
50G for 11ms
쮿
쮿
Vibration:
IEC 68-2-06 Test Fc
10-55Hz, 1.5mm. 55-500Hz, 10G
쮿
쮿
Part No
MA05178
MS09525
MA05179
MS08568
MS07546
쮿
쮿
Shock:
Freq
Option
Codes
HCD300
L
쮿 Standard. 왏 Optional - Please specify required code(s) when ordering
Ordering Information
Part No, or product name + option codes + frequency
eg: HCD300/BNDL 10.0MHz
HCD301/BMFL 5.0MHz
Option code X (eg HCD301/X) denotes a custom specification.
Tel: +44 1460 256 100
21 Nov 2003
Fax: +44 1460 256 101
E-mail: [email protected]