M50FF3 M50FF5 M100FF3 M100FF5 M160FF3 M160FF5 5,000 V - 16,000 V Rectifiers 10 mA - 40 mA Forward Current 30 ns - 50 ns Recovery Time AXIAL LEADED HERMETICALLY SEALED 4 ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS Part Number Working Reverse Voltage Average Rectified Current Reverse Current @ Vrwm Forward Voltage (Vrwm) (Io) (Ir) (Vf) 55°C(1) 100°C(2) 25°C 100°C 1 Cycle Repetitive Reverse Surge Surge Recovery Current Current Time tp=8.3ms (3) (Ifsm) (Ifrm) (Trr) 25°C 25°C 25°C 25°C Thermal Impedance Junction Cap. @50VDC @ 1kHZ (Cj) uJ-L L=.000 L=.125 L=.250 25°C Volts mA mA µA µA Volts mA Amps Amps ns °C/W °C/W °C/W pF M50FF3 M100FF3 M160FF3 5000 10000 16000 40 20 10 20 10 5 0.1 0.1 0.1 10 10 10 12.5 25.0 50.0 40 20 10 2.0 1.0 0.5 0.4 0.2 0.1 30 30 30 18 18 33 30 30 45 50.0 50.0 65.0 1.0 0.5 0.5 M50FF5 M100FF5 M160FF5 5000 10000 16000 40 20 10 20 10 5 0.1 0.1 0.1 10 10 10 12.5 25.0 50.0 40 20 10 2.0 1.0 0.5 0.4 0.2 0.1 50 50 50 18 18 33 30 30 45 50.0 50.0 65.0 1.0 0.5 0.5 (1)TL=55°C L=0.375" (2)TL=100°C L=0.375" (3)If=12.5mA, Ir=25mA, Irr=6.3mA • Op.Temp.= -65°C to +175°C Stg.Temp.= -65°C to +200°C .130(3.3) MAX. A 1.30(33.02) 1.00(25.4) Part .020 ±.003 (.50 ±.08) A M50FFX M100FFX .300(7.62) MAX. M160FFX .350(8.89) MAX. Dimensions: In. (mm) • All temperatures are ambient unless otherwise noted. • Data subject to change without notice. VOLTAGE MULTIPLIERS INC. 8711 W. Roosevelt Ave. Visalia, CA 93291 83 TEL 559-651-1402 FAX 559-651-0740 www.voltagemultipliers.com M50FF3 M100FF3 M160FF3 M50FF5 M100FF5 M160FF5 TYPICAL FORWARD VOLTAGE VS. FORWARD CURRENT AT 25°C POWER DERATING 50 L=0.200" L=0.100" 45 L=0.000" 40 3 Forward Voltage (V) Maximum Power Dissipation (W) Maxumum 4 2 L=0.300" L=0.400" L=0.500" 1 M100FF3/5 35 30 M50FF3/5 25 20 15 10 5 0 0 0 25 50 75 100 125 Lead Temperature Temperature (°C) (C) 150 175 0.0 REVERSE CURRENT VS. TEMPERATURE AT Vrwm 1000.0 0.1 0.2 0.3 Forward Current (A) 0.4 0.5 TYPICAL FORWARD VOLTAGE VS. FORWARD CURRENT AT 25°C 80 100.0 Forward Voltage (V) Reverse Current (uA) 70 10.0 1.0 60 M160FF3/5 50 40 30 20 10 0.1 0 25 75 100 Temperature (°C) Temperature (C) 125 150 0.0 TYPICAL REVERSE RECOVERY TIME VS. TEMPERATURE 140 120 0.1 0.2 0.3 Forward Current (A) 0.4 0.5 TYPICAL JUNCTION CAPACITANCE VS. REVERSE VOLTAGE AT 25°C 1.4 1.2 Junction Capacitance (pF) Reverse Recovery Time (ns) 50 100 80 60 40 20 1.0 0.8 M50FF3/5 0.6 M100FF3/5 0.4 0.2 0 M160FF3/5 0.0 25 50 75 100 Temperature (°C) Temperature (C) 125 150 0 84 20 40 60 Reverse Bias Voltage (V) 80 100