MCC FR3KB

MCC
TM
Micro Commercial Components
omponents
20736 Marilla Street Chatsworth
!"#
$
% !"#
Features
x
•
•
•
FR3AB
THRU
FR3MB
Case Material: Molded Plastic. UL Flammability
Classification Rating 94V-0
Easy Pick And Place
High Temp Soldering: 260°C for 10 Seconds At Terminals\
Fast Recovery Times For High Effieciency
3 Amp Fast Recovery
Silicon Rectifier
50 to 1000 Volts
DO-214AA
(SMB) (LEAD FRAME)
Maximum Ratings
•
•
•
Operating Temperature: -55°C to +150°C
Storage Temperature: -55°C to +150°C
Maximum Thermal Resistance; 10 °C/W Junction To Lead
MCC
Catalog
Number
FR3AB
FR3BB
FR3DB
FR3GB
FR3JB
FR3KB
FR3MB
Device
Marking
FR3AB
FR3BB
FR3DB
FR3GB
FR3JB
FR3KB
FR3MB
Maximum
Recurrent
Peak Reverse
Voltage
50V
100V
200V
400V
600V
800V
1000V
Maximum
RMS
Voltage
35V
70V
140V
280V
420V
560V
700V
A
Maximum
DC
Blocking
Voltage
50V
100V
200V
400V
600V
800V
1000V
B
C
F
D
G
E
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
IF(AV)
3.0A
TJ = 120°C
Current
Peak Forward Surge
IFSM
100A
8.3ms, half sine
Current
Maximum
VF
1.30V
IFM = 3.0A;
Instantaneous
Forward Voltage
TJ = 25°C*
Maximum DC
Reverse Current At
IR
10µA
TJ = 25°C
Rated DC Blocking
250µA TJ = 100°C
Voltage
Maximum Reverse
Recovery Time
150ns IF=0.5A, IR=1.0A,
FR3AB-GB
Trr
250ns Irr=0.25A
FR3JB
500ns
FR3KB-MB
Typical Junction
80pF
Measured at
CJ
1.0MHz, VR=4.0V
Capacitance
*Pulse test: Pulse width 200 µsec, Duty cycle 2%
H
DIMENSIONS
DIM
A
B
C
D
E
F
G
H
INCHES
MIN
.160
.130
.006
.030
.200
.079
.075
.002
MM
MIN
4.06
3.30
0.15
0.76
5.08
2.01
1.91
0.05
MAX
.185
.155
.012
.060
.220
.103
.087
.008
MAX
4.70
3.94
0.31
1..52
5.59
2.62
2.21
0.203
NOTE
SUGGESTED SOLDER
PAD LAYOUT
0.106
0.083”
0.050”
www.mccsemi.com
Revision: 2
1 of 4
2006/05/19
MCC
FR3AB thru FR3MB
Figure 1
Typical Forward Characteristics
TM
Micro Commercial Components
100
60
Figure 2
Forward Derating Curve
40
3.0
20
2.5
10
6
2.0
4
1.5
25°C
2
Amps
1
Amps
1.0
.6
.5
.4
.2
Single Phase, Half Wave
60Hz Resistive or Inductive Load
0
60
40
100
80
120
140
160
.1
°C
.06
Average Forward Rectified Current - Amperesversus
Ambient Temperature - °C
.04
.02
.01
.4
.6
.8
1.0
1.2
1.4
Figure 3
Peak Forward Surge Current
150
1.6
Volts
125
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
100
75
Amps
50
25
0
1
2
4
6
8 10
20
40
60 80 100
Cycles
Peak Forward Surge Current - Amperesversus
Number Of Cycles At 60Hz - Cycles
www.mccsemi.com
Revision: 2
3 of 4
2006/05/19
MCC
FR3AB thru FR3MB
Figure 4
Typical Reverse Characteristics
Micro Commercial Components
1000
600
400
200
100
60
40
TA=100°C
20
µAmps 10
6
4
2
TA=75°C
1
.6
.4
TA=25°C
.2
.1
20
40
60
80
100
120
140
Volts
Instantaneous Reverse Leakage Current - MicroAmperesversus
Percent Of Rated Peak Reverse Voltage - Volts
Figure 5
Reverse Recovery Time Characteristic And Test Circuit Diagram
50Ω
10Ω
trr
+0.5A
0
Pulse
Generator
Note 2
25Vdc
1Ω
Oscilloscope
Note 1
-0.25
-1.0
1cm
Set Time Base for 20/100ns/cm
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive
www.mccsemi.com
Revision: 2
3 of 4
2006/05/19
TM
MCC
TM
Micro Commercial Components
***IMPORTANT NOTICE***
Micro Commercial Components Corp . reserves the right to make changes without further notice to any
product herein to make corrections, modifications , enhancements , improvements , or other changes .
Micro Commercial Components Corp . does not assume any liability arising out of the application or
use of any product described herein; neither does it convey any license under its patent rights ,nor
the rights of others . The user of products in such applications shall assume all risks of such use
and will agree to hold Micro Commercial Components Corp . and all the companies whose
products are represented on our website, harmless against all damages.
***APPLICATIONS DISCLAIMER***
Products offer by Micro Commercial Components Corp . are not intended for use in Medical,
Aerospace or Military Applications.
www.mccsemi.com
Revision: 2
4 of 4
2006/05/19