MCC MBR30100PT

MCC
TM
Micro Commercial Components
omponents
20736 Marilla Street Chatsworth
!"#
$
% !"#
MBR30100PT
30 Amp
Features
•
•
•
•
Schottky
Metal of siliconrectifier , majonty carrier conduction
Guard ring for transient protection
Low power loss high efficiency
High surge capacity , High current capability
Barrier Rectifier
100Volts
Maximum Ratings
•
•
Operating J unction Temperature : 150°C
Storage Temperature: - 5 0°C to +150°C
TO-247
C
E
B
MCC
Catalog
Number
MBR 30100PT
Maximum
Recurrent
Peak Reverse
Voltage
100 V
Maximum
RMS
Voltage
70V
Maximum
DC
Blocking
Voltage
100 V
A
PIN
2
1
Q
3
P
F
K
V
J
D
Electrical Characteristics @ 25°C Unless Otherwise Specified
Average Forward
Current
Peak Forward Surge
Current
Maximum
Instantaneous
Forward Voltage
Maximum
Reverse Current At
Rated DC Blocking
Voltage
IF(AV)
30 A
TC = 100°C
IFSM
200A
8.3ms, half
sine wave
G
PIN 1
PIN 3
PIN 2
CASE
VF
.85V
IR
500 µ A
7m A
I FM = 15A
TJ = 25°C
TJ = 25°C
TJ = 125°C
A
B
C
D
E
F
J
K
P
Q
V
B
INCHES
.803
.856
.608
.640
.185
.205
.043
.051
.059
.082
.071
.086
.019
.030
.772
.791
.122
.172
.138
.145
.115
.134
.205
.224
MM
20.40
15.44
4.70
1.09
1.50
1.80
0.48
19.60
3.10
3.50
2.93
5.20
21.75
16.25
5.21
1.30
2.08
2.18
0.76
20.10
4.38
3.70
3.40
5.70
* Pulse Test: Pulse Width380µsec, Duty Cycle 2%
www.mccsemi.com
Revision: 2
2004/03/08
MCC
RATING AND CHARACTERISTIC CURVES
MBR30100PT
TM
Micro Commercial Components
Figure 2
Typical Reverse Characteristics
Figure 1
Typical Forward Characteristics
200
100
10
125°C
1.0
Amps
25°C
mAmps
10
0.1
50°C
0.01
1
25°C
0.001
.5
0
0.5
1.0
1.5
2.0
2.5
Instantaneous Forward Current - Amperesversus
Instantaneous Forward Voltage - Volts
0.0001
0
40
300
30
200
20
10
40
60
80
100
Figure 4
Peak Forward Surge Current
Figure 3
Forward Current Derating Curve
Amps
20
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
150
Amps
Resistive Or
Inductive Load
100
50
0
25
50
75
100
125
150
175
0
Average Forward Rectified Current - Amperes versus
Ambient Temperature - °C
1
2
4
6
8 10 20
40
60 80 100
Cycles
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Revision: 1