MCC TM Micro Commercial Components omponents 20736 Marilla Street Chatsworth !"# $ % !"# MBR30100PT 30 Amp Features • • • • Schottky Metal of siliconrectifier , majonty carrier conduction Guard ring for transient protection Low power loss high efficiency High surge capacity , High current capability Barrier Rectifier 100Volts Maximum Ratings • • Operating J unction Temperature : 150°C Storage Temperature: - 5 0°C to +150°C TO-247 C E B MCC Catalog Number MBR 30100PT Maximum Recurrent Peak Reverse Voltage 100 V Maximum RMS Voltage 70V Maximum DC Blocking Voltage 100 V A PIN 2 1 Q 3 P F K V J D Electrical Characteristics @ 25°C Unless Otherwise Specified Average Forward Current Peak Forward Surge Current Maximum Instantaneous Forward Voltage Maximum Reverse Current At Rated DC Blocking Voltage IF(AV) 30 A TC = 100°C IFSM 200A 8.3ms, half sine wave G PIN 1 PIN 3 PIN 2 CASE VF .85V IR 500 µ A 7m A I FM = 15A TJ = 25°C TJ = 25°C TJ = 125°C A B C D E F J K P Q V B INCHES .803 .856 .608 .640 .185 .205 .043 .051 .059 .082 .071 .086 .019 .030 .772 .791 .122 .172 .138 .145 .115 .134 .205 .224 MM 20.40 15.44 4.70 1.09 1.50 1.80 0.48 19.60 3.10 3.50 2.93 5.20 21.75 16.25 5.21 1.30 2.08 2.18 0.76 20.10 4.38 3.70 3.40 5.70 * Pulse Test: Pulse Width380µsec, Duty Cycle 2% www.mccsemi.com Revision: 2 2004/03/08 MCC RATING AND CHARACTERISTIC CURVES MBR30100PT TM Micro Commercial Components Figure 2 Typical Reverse Characteristics Figure 1 Typical Forward Characteristics 200 100 10 125°C 1.0 Amps 25°C mAmps 10 0.1 50°C 0.01 1 25°C 0.001 .5 0 0.5 1.0 1.5 2.0 2.5 Instantaneous Forward Current - Amperesversus Instantaneous Forward Voltage - Volts 0.0001 0 40 300 30 200 20 10 40 60 80 100 Figure 4 Peak Forward Surge Current Figure 3 Forward Current Derating Curve Amps 20 Instantaneous Reverse Leakage Current - MicroAmperes versus Percent Of Rated Peak Reverse Voltage - Volts 150 Amps Resistive Or Inductive Load 100 50 0 25 50 75 100 125 150 175 0 Average Forward Rectified Current - Amperes versus Ambient Temperature - °C 1 2 4 6 8 10 20 40 60 80 100 Cycles Peak Forward Surge Current - Amperes versus Number Of Cycles At 60Hz - Cycles Revision: 1 www.mccsemi.com 2004/03/08