MICREL SY100E158JZ

5-BIT 2:1
MULTIPLEXER
Micrel, Inc.
FEATURES
DESCRIPTION
■ 550ps max. D to output
■ Extended 100E VEE range of –4.2V to –5.5V
The SY10/100E158 offer five 2:1 multiplexers with
differential outputs, designed for use in new, highperformance ECL systems.
The multiplexer operation is controlled by the SEL (Select)
signal which selects one of the two bits of input data at each
mux to be passed through.
■ 775ps max. SEL to output
■ Differential outputs
■ Fully compatible with industry standard 10KH,
100K ECL levels
■ Internal 75KΩ input pulldown resistors
■ Fully compatible with Motorola MC10E/100E158
■ Available in 28-pin PLCC package
PIN NAMES
BLOCK DIAGRAM
Pin
D0a
D0b
MUX
SEL
D1a
D1b
D3b
Input Data a
Q0
D0b–D4b
Input Data b
SEL
Select Input
Q0–Q4
True Outputs
Q0–Q4
Inverted Outputs
VCCO
VCC to Outputt
MUX
SEL
Q2
MUX
SEL
Q3
MUX
SEL
Q4
D4a
D4b
D0a–D4a
Q1
D3a
Function
Q0
MUX
SEL
D2a
D2b
SY10E158
SY100E158
SY10E158
SY100E158
Q1
Q2
Q3
Q4
SEL
M9999-032006
[email protected] or (408) 955-1690
1
Rev.: E
Amendment: /0
Issue Date: March 2006
SY10E158
SY100E158
Micrel, Inc.
Ordering Information(1)
Q4
VCCO
Q4
D3a
VCCO
D4a
D3b
PACKAGE/ORDERING INFORMATION
Part Number
Package
Type
Operating
Range
Package
Marking
Lead
Finish
Q3
SY10E158JC
J28-1
Commercial
SY10E158JC
Sn-Pb
Q3
VCC
Q2
SY10E158JCTR(2)
J28-1
Commercial
SY10E158JC
Sn-Pb
SY100E158JC
J28-1
Commercial
SY100E158JC
Sn-Pb
SY100E158JCTR(2)
J28-1
Commercial
SY100E158JC
Sn-Pb
SY10E158JZ(3)
J28-1
Commercial
SY10E158JZ with
Pb-Free bar-line indicator
Matte-Sn
SY10E158JZTR(2, 3)
J28-1
Commercial
SY10E158JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E158JZ(3)
J28-1
Commercial
SY100E158JZ with
Pb-Free bar-line indicator
Matte-Sn
SY100E158JZTR(2, 3)
J28-1
Commercial
SY100E158JZ with
Pb-Free bar-line indicator
Matte-Sn
25 24 23 22 21 20 19
D4b
26
18
D2a
D2b
VEE
27
17
28
16
SEL
D0a
2
3
13
Q2
VCCO
D0b
4
12
Q1
PLCC
TOP VIEW
J28-1
8
14
9
10 11
Q0
7
15
VCCO
Q1
6
D1a
D1b
5
VCCO
Q0
1
28-Pin PLCC (J28-1)
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
M9999-032006
[email protected] or (408) 955-1690
2
SY10E158
SY100E158
Micrel, Inc.
TRUTH TABLE
SEL
Data
H
a
L
b
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
IIH
Parameter
Min. Typ. Max. Min. Typ.
TA = +85°C
Max. Min. Typ.
Max.
Input HIGH Current
D
SEL
IEE
TA = +25°C
—
—
—
—
200
150
—
—
—
—
200
150
—
—
—
—
200
150
—
—
33
33
40
40
—
—
33
33
40
40
—
—
33
38
40
46
Power Supply Current
10E
100E
Unit
Condition
µA
—
mA
—
Unit
Condition
ps
—
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°C
Symbol
tPD
Parameter
Propagation Delay to Output
D
SEL
tskew
Within-Device Skew
tr
tf
Rise/Fall Time
20% to 80%
TA = +25°C
TA = +85°C
Min. Typ. Max. Min. Typ.
Max. Min. Typ.
Max.
225
400
550
775
550
775
385
600
550
775
225
400
385
600
385
600
—
60
—
—
60
—
—
60
—
ps
1
275
425
650
275
425
650
275
425
650
ps
—
Note:
1. Within-device skew is defined as identical transitions on similar paths through a device.
M9999-032006
[email protected] or (408) 955-1690
225
400
3
SY10E158
SY100E158
Micrel, Inc.
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 474-1000
WEB
USA
http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser’s
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser’s own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.
M9999-032006
[email protected] or (408) 955-1690
4