Sensing Supply voltage Output 10 to 30 VDC 7m 2m 20 cm, 70 cm General-Purpose Photoelectric Sensor 100 mA E3S-A Wide Selection of High Performance Small DC Sensors Offers Longer Sensing Distances ■ Fast 0.5 msec response time for high-speed sensing ■ Extended sensing distances up to 7 meters ■ Self-diagnostic functions available ■ User-friendly features for easy installation and use ■ Meets: NEMA 4X, 6 and IP67 ■ Many mounting configurations available ■ Choose prewired or connector-ready models ■ E3S-AD Series includes 10 cm short range diffuse version Ordering Information ■ SENSORS Through-beam sensors include both emitter and receiver. The polarized retroreflective sensors include E39-R1 reflector. All sensors include mounting hardware. Optional mounting brackets are available as accessories. Method of detection Sensing distance Mounting Output Extra features Horizontal NPN None None Timer, alarm and turbo Vertical Connection Prewired Connector Prewired Through-beam 7 m (22.97 ft) Part number E3S-AT11 E3S-AT16 E3S-AT21 Retroreflective Diffuse reflective 2 m (6.56 ft) 10 cm (3.94 in) 20 cm (7.87 in) 70 cm (2.3 ft) E3S-AR11 E3S-AR16 E3S-AR21 E3S-AD13 E3S-AD18 E3S-AD23* E3S-AD11 E3S-AD16 E3S-AD21 E3S-AD12 E3S-AD17 E3S-AD22* PNP None None Timer, alarm and turbo Prewired Connector Prewired E3S-AT31 E3S-AT36 E3S-AT41 E3S-AR31 E3S-AR36 E3S-AR41 E3S-AD33 E3S-AD38 E3S-AD43* E3S-AD31 E3S-AD36 E3S-AD41 E3S-AD32 E3S-AD37 E3S-AD42* NPN None None Timer, alarm and turbo Prewired Connector Prewired E3S-AT61 E3S-AT66 E3S-AT71 E3S-AR61 E3S-AR66 E3S-AR71 E3S-AD63 E3S-AD68 E3S-AD73* E3S-AD61 E3S-AD66 E3S-AD71 E3S-AD62 E3S-AD67 E3S-AD72* PNP None None Timer, alarm and turbo Prewired Connector Prewired E3S-AT81 E3S-AT86 E3S-AT91 E3S-AR81 E3S-AR86 E3S-AR91 E3S-AD83 E3S-AD88 E3S-AD93* E3S-AD81 E3S-AD86 E3S-AD91 E3S-AD82 E3S-AD87 E3S-AD92* *10 and 70 cm diffuse versions do not have turbo function E3S-A E3S-A ■ ACCESSORIES Description Mounting bracket for vertical sensors (2 required for through-beam type) Slits for E3S-AT❑❑ sensors (3 pairs: 2 mm, 1 mm and 0.5 mm wide, includes mounting hardware) Mutual interference filters for E3S-AT❑❑ sensors (2 pairs: horizontal and vertical, includes mounting hardware) Optical alignment reflector for E3S-AT❑❑ Straight connector cordsets 2 m (6.56 ft) cable (4-pole female connector) 5 m (16.40 ft) cable 10 m (32.81 ft) cable Right-angle connector cordsets 2 m (6.56 ft) cable (4-pole female connector) 5 m (16.40 ft) cable 10 m (32.81 ft) cable Small corner cube reflector 10 to 130 cm (3.94 to 51.18 in) 7 to 60 cm (2.76 to 23.62 in) Adhesive back reflector 10 to 30 cm (3.94 to 11.81 in) 10 to 60 cm (3.94 to 23.62 in) Mounting bracket for E39-R1 reflector Part number E39-L59 E39-S46 E39-E6 E39-R5 Y96E-43SD2 Y96E-43SD5 Y96E-43SD10 Y96E-43RD2 Y96E-43RD5 Y96E-43RD10 E39-R3 E39-R4 E39-RSA E39-RSB E39-L7 ■ REPLACEMENT PARTS Description Knob for sensitivity adjuster Mounting bracket spacer for connector versions Corner cube reflector (supplied with E3S-AR❑❑) Mounting bracket for horizontal sensors (supplied with each sensor) Mounting bracket for vertical sensors (supplied with each sensor) Part number E39-G2 E39-L60 E39-R1 E39-L69 E39-L70 Specifications Part number E3S-AT❑❑ Method of detection Through-beam Supply voltage Current consumption Sensing distance Standard object 2 Polarized retroreflective 10 to 30 VDC, ±10% 40 mA max. 30 mA max. (emitter and 45 mA with turbo receiver) 55 mA with turbo 0 to 7 m 0.1 to 2 m with E39-R1 (0 to 22.97 ft) (0.33 to 6.56 ft) White mat paper Black mat paper With 2.4 m (7.87 ft) accessories with E39-E6 2.5 m (8.20 ft) with 2 mm slit 1.1 m (3.61 ft) with 1 mm slit 0.5 m (1.64 ft) with 0.5 mm slit Light source E3S-AR❑❑ 10 to 130 cm with E39-R3 (3.94 to 51.18 in) 7 to 60 cm with E39-R4 (2.76 to 23.62 in) 10 to 30 cm with E39-RSA (3.94 to 11.81 in) 10 to 60 cm with E39-RSB (3.94 to 23.62 in) Pulse modulated red LED (700 nm) Type Size Opaque materials 7 mm (0.28 in) 30 mm (1.18 in) minimum minimum E3S-AD❑3, E3S-AD❑8 Diffuse reflective E3S-AD❑1, E3S-AD❑6 35 mA max. 30 mA max. 35 mA max. 45 mA with turbo 0 to 10 cm (0 to 3.94 in) 0.3 to 2.5 cm (0.12 to 0.98 in) — 0.1 to 20 cm (0.04 to 7.87 in) 0.5 to 2.3 cm (0.20 to 0.91 in) — Pulse modulated Pulse modulated infrared LED red LED (880 nm) (700 nm) Opaque and transparent materials 10 x 10 cm (3.94 x 3.94 in) white mat paper Operation mode Variation in sensing distance Light-ON/Dark-ON operation, switch selectable — — +30% max., –0% max. Hysteresis Variation in optical axis and mounting direction — ±2° max. — 10% max. E3S-AD❑2, E3S-AD❑7 0 to 70 cm (0 to 27.56 in) 0.15 to 33 cm (0.06 to 12.99 in) — Pulse modulated infrared LED (880 nm) 20 x 20 cm (7.87 x 7.87 in) white mat paper 20% max. E3S-A E3S-A SPECIFICATIONS (continued) Part number E3S-AT❑❑ Sensitivity Mutual interference protection Adjustable, 2-turn knob with clutch and indicator Not provided Provided Provided Control output NPN transistor, open collector (E3S-A❑1❑, E3S-A❑2❑, E3S-A❑6❑, E3S-A❑7❑), (E3S-AD1❑, E3S-AD2❑, E3S-AD6❑, E3S-AD7❑) PNP transistor, open collector (E3S-A❑3❑, E3S-A❑4❑, E3S-A❑8❑, E3S-A❑9❑), (E3S-AD3❑, E3S-AD4❑, E3S-AD8❑, E3S-AD9❑) 100 mA max. at 30 VDC Type Max. load E3S-AR❑❑ E3S-AD❑3, E3S-AD❑8 E3S-AD❑1, E3S-AD❑6 E3S-AD❑2, E3S-AD❑7 Provided Provided Max. 1 VDC max. at 100 mA load current ON-state voltage drop Self-diagnostics 50 mA max. load at 30 VDC, NPN or PNP transistor open collector to match control output alarm output Response time OFF-delay timer 0.5 ms max. ON, 0.5 ms max. OFF 0 to 100 ms with 3/4 turn adjuster Check input Light OFF: gray wire connected to 0 to 1.5 VDC — Light OFF: gray wire connected to supply — voltage (30 VDC max.) 0.5 ms max. — NPN PNP Response time Circuit protection Indicators Materials Lens Case Bracket Mounting Connections Prewired Connector Weight Prewired Connector Enclosure rating IEC 144 NEMA Ambient Operating temperature Storage — — — — 0.5 ms max. Load short-circuit protection, reverse polarity protection Emitter: Operation (red), Stability (green) Operation (red) Receiver: Operation (red) Stability (green) Denatured polyarylate Polybutylene terephthalate (PBT) Stainless steel Either side surface with two threaded holes. Bracket E39-L69 for horizontal or E39-L70 for vertical sensors and hardware included. 2 m (6.56 ft) long cable M12 threaded connector, 4 pin Emitter: 60 g (2.1 oz.) 60 g (2.1 oz.) 60 g (2.1 oz.) 60 g (2.1 oz.) 60 g (2.1 oz.) Receiver: 60 g (2.1 oz.) Emitter: 11 g (0.4 oz.) 11 g (0.4 oz.) 11 g (0.4 oz.) 11 g (0.4 oz.) 11 g (0.4 oz.) Receiver: 11 g (0.4 oz.) IP67 4X, 6 -25° to 55°C (-13° to 131°F) with no ice build-up -40° to 70°C (-40° to 158°F) ■ OUTPUT CIRCUIT DIAGRAMS NPN Cable Type Through-beam emitter E3S-AT11, E3S-AT61 Through-beam receiver E3S-AT11, E3S-AT61 Retroreflective E3S-AR11, E3S-AR61 Diffuse reflective E3S-AD11, E3S-AD12, E3S-AD13, E3S-AD61, E3S-AD62, E3S-AD63 Light Stability (Red) (Green) Red (Brown) Red (Brown) 10 to 30 VDC Main circuit Black (Blue) Main circuit ZD Load White (Black) (relay) 10 to 30 VDC 100 mA max. Black (Blue) NOTE: IEC colors are shown in parentheses. 3 E3S-A E3S-A NPN Cable Type with Self-Diagnostic Functions Through-beam emitter E3S-AT21, E3S-AT71 Through-beam receiver E3S-AT21, E3S-AT71 Diffuse reflective E3S-AD21, E3S-AD22, E3S-AD71, E3S-AD72 Red (Brown) 10 to 30 VDC Main circuit Light Stability (Red) (Green) Red (Brown) Load (relay) Grey (Pink) 100 mA max. Check input Main circuit ZD 50 mA max. 0V Load White (Black) (relay) Control output (Orange) Self-diagnostic output Black (Blue) ZD 10 to 30 VDC Black (Blue) NPN Cable Type with Alarm Output NPN Cable Type with Self-Diagnostic Functions Diffuse reflective E3S-AD23, E3S-AD73 Retroreflective E3S-AR21, E3S-AR71 Light Stability (Red) (Green) Light Stability (Red) (Green) Red (Brown) Load (relay) 100 mA max. Main circuit Red (Brown) Load White (Black) (relay) Control output ZD 50 mA max. (Orange) Alarm output ZD 100 mA max. Main circuit 10 to 30 VDC Load (relay) Load White (Black) (relay) Control output Orange Self-diagnostic output ZD 50 mA max. ZD 12K Black (Blue) Gray (Pink) 10 to 30 VDC Check input Black (Blue) NPN Connector Type Through-beam emitter Through-beam receiver E3S-AT16, E3S-AT66 E3S-AT16, E3S-AT66 Retroreflective E3S-AR16, E3S-AR66 Diffuse reflective E3S-AD16, E3S-AD17, E3S-AD18, E3S-AD66, E3S-AD67, E3S-AD68 Load Output (relay) PNP Cable Type Through-beam emitter E3S-AT31, E3S-AT81 Light Stability (Red) (Green) Red (Brown) Main circuit Through-beam receiver E3S-AT31, E3S-AT81 Retroreflective E3S-AR31, E3S-AR81 Diffuse reflective E3S-AD31, E3S-AD32, E3S-AD33, E3S-AD81, E3S-AD82, E3S-AD83 Red (Brown) 10 to 30 VDC Black (Blue) ZD Main circuit Control output White (Black) 100 mA max. Load Black (Blue) (relay) 4 NOTE: IEC colors are shown in parentheses. 10 to 30 VDC E3S-A E3S-A PNP Cable Type with Self-Diagnostic Functions Through-beam emitter E3S-AT41, E3S-AT91 Through-beam receiver E3S-AT41, E3S-AT91 Diffuse reflective E3S-AD41, E3S-AD42, E3S-AD91, E3S-AD92 Red (Brown) 10 to 30 VDC Red (Brown) Check input Light Stability (Red) (Green) Gray (Pink) Main circuit ZD Self-diagnostic output 50 mA max. Orange Black (Blue) ZD Main circuit 0V 100 mA max. Control output White (Black) Load (relay) 10 to 30 VDC Load (relay) Black (Blue) PNP Cable Type with Alarm Output Diffuse reflective E3S-AD43, E3S-AD93 Retroreflective E3S-AR41, E3S-AR91 Red (Brown) Red (Brown) Light Stability (Red) (Green) Alarm output ZD 50 mA max. ZD Main circuit Light Stability (Red) (Green) 100 mA max. Orange (White) Control output White (Black) Load (relay) 10 to 30 VDC Load (relay) Black (Blue) Check input 4.4K Main circuit ZD 50 mA max. ZD 100 mA max. Gray (Pink) Selfdiagnostic Orange output 10 to 30 VDC Control output White (Black) Load (relay) Load (relay) Black (Blue) PNP Connector Type Through-beam emitter E3S-AT36, E3S-AT86 Through-beam receiver E3S-AT36, E3S-AT86 Retroreflective E3S-AR36, E3S-AR86 Diffuse reflective E3S-AD36, E3S-AD37, E3S-AD38, E3S-AD86, E3S-AD87, E3S-AD88, Output Load (relay) NOTE: IEC colors are shown in parentheses. 5 E3S-A E3S-A Engineering Data ■ EXCESS GAIN RATIO E3S-AD❑1, -AD❑2 (Detection of White Paper) 300 500 300 100 100 Excess gain ratio 50 30 10 5 100 Sensing object: white (E3S-AD■ ■ 2: 20 x 20 cm E3S-AD■ ■ 1: 10 x 10 cm) 50 30 10 5 3 0 3 5 Distance (m) 7 10 E3S-AD❑1, -AD❑2 (White Paper within Short Distance) 20 40 1 60 80 Distance (cm) 100 120 0.1 20 E3S-AD■ ■1 10 5 10 5 2 1 0 1 2 3 4 5 6 Distance (cm) 7 8 9 E3S-AD■ ■ 3, -AD■ ■8 (Detection of Black Paper) E3S-AD■ ■2 20 1 E3S-AD■ ■1 0 1 2 3 4 5 6 Distance (cm) 7 8 9 100 Sensing object: black (E3S-AD■ ■ 3/E3SAD■ ■ 8: 10 x 10 cm) 50 30 Excess gain ratio 5 4 3 2 10 5 3 1 1 20 40 60 Distance X (mm) 80 100 40 60 Distance (cm) 80 E3S-AD■ ■ 3, -AD■ ■8 (Detection of White Paper) Sensing object: white (E3S-AD■ ■ 3/E3SAD■ ■ 8: 10 x 10 cm) 4 3 2 1 E3S-AR❑1 (With Reflector: E39-R1) 6 20 5 50 2 0 6 100 E3S-AD■ ■2 50 E3S-AD■ ■2 E3S-AD■ ■1 0.3 Sensing object: white (E3S-AD■ ■ 2: 20 x 20 cm E3S-AD■ ■ 1: 10 x 10 cm) 200 Excess gain ratio Excess gain ratio 100 Excess gain ratio 5 3 500 Sensing object: white (E3S-AD■ ■ 2: 20 x 20 cm E3S-AD■ ■ 1: 10 x 10 cm) 200 6 0 E3S-AD❑1, -AD❑2 (Black Paper within Short Distance) 500 0 E3S-AD■ ■2 E3S-AD■ ■1 1 0.5 10 2.5 3 1 Sensing object: black (E3S-AD■ ■ 2: 20 x 20 cm E3S-AD■ ■ 1: 10 x 10 cm) 50 30 Excess gain ratio Excess gain ratio 500 E3S-AD❑1, -AD❑2 (Detection of Black Paper) Excess gain ratio Excess Gain vs. Set Distance (Typical) E3S-AT❑1 Operating level 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2 2.2 2.4 2.6 Distance (m) 0 50 100 150 Distance X (mm) 200 E3S-A E3S-A ■ OPERATING RANGE Operating Range (Typical) E3S-AD❑1 10 40 8 30 6 20 Y 10 X 0 2 10 4 6 8 Distance X (m) 20 30 E3S-AD❑2 4 X 4 2 10 0 Distance X (cm) 20 2 4 6 40 8 50 10 0 -20 -40 20 40 60 200 Sensing object: white OFF Y 40 X 20 0 -20 180 0 20 160 140 120 40 60 ■ SENSING DISTANCE VS. OBJECT SIZE E3S-AD❑1 5 10 15 20 25 30 35 Area of object (cm) ■ REFLECTOR PARALLEL MOVEMENT E3S-AD❑2 38 (Typical) E3S-AR❑1 20 Sensing object: white 10 Sensing object: white 10 34 ON 28 26 24 Sensing distance (cm) OFF OFF 00 ON 90 80 70 22 Parallel operating range Y (cm) 36 Sensing distance (cm) 0 80 100 120 140 160 Distance X (mm) Distance X (mm) 30 ON -40 80 100 120 140 160 32 Distance X (cm) 80 E3S-AD■ ■ 3, E3S-AD■ ■8 -60 0 60 2 100 -60 40 1 Sensing distance (mm) X 20 20 0 4 E3S-AD■ ■ 3, E3S-AD■ ■ 8 (Up and Down) Operating position Y (mm) Operating position Y (mm) 1 60 40 X ■ SENSING DISTANCE VS. OBJECT SIZE 60 Y Y 2 3 ■ OPERATING RANGE (typical) E3S-AD■ ■ 3, E3S-AD■ ■ 8 (Left and Right) 3 Y Operating position Y (mm) 50 Operating position Y (mm) Parallel operating range Y (cm) Parallel Operating Range (Typical) E3S-AT❑1 8 6 4 Y 2 0 2 X 0.5 1.0 1.5 Distance X (m) 2.0 2.5 4 6 8 20 60 0 5x5 10x10 20x20 Size of object (cm) 30x30 10 0 5x5 10x10 20x20 30x30 Size of object (cm) 7 E3S-A E3S-A Dimensions Unit: mm (inch) ■ SENSORS E3S-AD11, E3S-AD12, E3S-AD13, E3S-AD31, E3S-AD32, E3S-AD33 (see note 1), E3S-AD21, E3S-AD22, E3S-AD23, E3S-AD41, E3S-AD42, E3S-AD43 Receiver: E3S-AT11, E3S-AT31 (see note 2) E3S-AT21, E3S-AT41 Emitter: E3S-AT11, E3S-AT31 (see note 3) E3S-AT21, E3S-AT41 Sensitivity adjuster (white) Light indicator (red) 12.9 40 (1.57) 5.5 7 Time adjuster (black) 4 Turbo switch Light indicator (red) 4 40 (1.57) 12.9 12.5 12.4 12 (0.49) 12.4 12 (0.49) Stability indicator (green) Lens 7 x 7 Optical axis 1.3 1.3 22.3 (0.88) 21 22.3 (0.88) 8 2.5 10.5 20 10.5 M3 holes (typ.) E3S-AD61, E3S-AD62, E3S-AD63, E3S-AD81, E3S-AD82, E3S-AD83 (see note 1), E3S-AD71, E3S-AD72, E3S-AD73, E3S-AD91, E3S-AD92, E3S-AD93 Receiver: E3S-AT61, E3S-AT81 (see note 2) E3S-AT71, E3S-AT91 20 Emitter: E3S-AT61, E3S-AT81 (see note 3) E3S-AT71, E3S-AT91 Optical axis Lens 7 x 7 12.4 13.5 40 8.3 Optical axis 4 12 Stability indicator Light indicator (red) Sensitivity (green) adjuster (white) 3.6 Time adjuster (Turbo switch) 7 (black) 21 Lens 7 x 7 13.5 40 8.3 4 12.4 12 1.3 1.3 Turbo switch 5.5 2.5 10.5 20 M3 holes (typ.) 10.5 NOTES: 1. No time adjuster/turbo included on models E3S-AD61, E3S-AD62, E3S-AD81and E3S-AD82. 2. No time adjuster included on models E3S-AT61 and E3S-AT81. 3. No turbo switch included on models E3S-AT61 and E3S-AT81. 8 20 E3S-A E3S-A SENSORS (continued) E3S-AD16, E3S-AD17, E3S-AD18, E3S-AD36, E3S-AD37, E3S-AD38 Receiver: E3S-AT16, E3S-AT36 Sensitivity adjuster (white) (receiver only) 50 (1.97) Light indicator (red) 40 12.9 Emitter: E3S-AT16, E3S-AT36 M12 connector Light indicator (red) 40 10 7 M12 connector 10 17.8 12.4 12 (0.49) 12.4 12 Stability indicator (green) Lens 7 x 7 Optical axis 1.3 1.3 21 8 2.5 10.5 10.5 20 E3S-AD66, E3S-AD67, E3S-AD68, E3S-AD86, E3S-AD87, E3S-AD88 Receiver: E3S-AT66, E3S-AT86 Lens 7 x 7 51.3 (2.02) Emitter: E3S-AT66, E3S-AT86 M12 connector 40 13.5 10 13.5 8.3 12 (0.47) 3.6 M12 connector 10 40 8.3 12 Optical axis Stability indicator (green) 20 Light indicator (red) Sensitivity adjuster (white) Lens 7 x 7 1.3 Optical axis 1.3 7 21 (0.83) 2.5 10.5 20 10.5 20 Sensitivity OFF-delay time adjuster/turbo adjuster switch (black) (white) Turn to adjust the OFF-delay time: push to switch turbo function on. E3S-AR11, E3S-AR31 (see note) E3S-AR21, E3S-AR41 42.3 15.2 2.3 Light indicator (red) 7 9 5.5 12.4 12 Stability indicator (green) Lens 7 x 14 Receiver 1.3 Optical axis 21.3 (0.89) 21 11.5 2.5 Emitter 2.3 10.5 20 NOTE: No time adjuster/turbo included on models E3S-AR11 and E3S-AR31. 9 E3S-A E3S-A SENSORS (continued) E3S-AR61, E3S-AR81 E3S-AR71, E3S-AR91 Receiver Optical axis Emitter Lens 7 x 14 13.5 12.4 (0.49) Stability indicator (green) 5.9 40 8.3 4 12 12 Light indicator (red) Sensitivity adjuster (white) OFF-delay time adjuster/turbo switch (black) Turn to adjust the OFF-delay time: push to switch turbo function 7 23.3 (0.92) 5.5 2.5 1.3 10.5 20 E3S-AR16, E3S-AR36 M3 holes (typ.) Sensitivity adjuster (white) 42.3 7 15.2 2.3 Light indicator (red) 10 M12 connector 12.4 12 Stability indicator (green) Lens 7 x 14 Receiver Optical axis 1.3 21 11.5 2.5 10.5 20 Emitter E3S-AR66, E3S-AR86 Optical axis Receiver Emitter Lens 7 x 14 10 40 17 14.9 Stability indicator (green) 3.6 12 Light indicator (red) Sensitivity adjuster (white) 7 10 21 2.5 1.3 10 10.5 20 M12 connector E3S-A E3S-A ■ OPTIONAL CONNECTOR CORDSETS Cordsets consist of a female connector and 3-conductor, 22 AWG, PVC jacketed cable rated for 300 V, 90°C. The cable may be extended to a maximum of 200 m (656 ft). Straight Connector Cordsets Y96E-43SD❑ Face View, Female Connector 34.92 (1.32) 14.67 (0.57) 45° 2. Output* White 90° Aluminum coupling nut Silver-plated copper contacts 2 m (6.56 ft) length for Y96E-43SD2 5 m (16.40 ft) length for Y96E-43SD5 10 m (32.81 ft) length for Y96E-43SD10 1. +V Red (Brown) 3. 0 V Black (Blue) 4. Output White (Black) NOTES: *Not used on 3-wire models. IEC colors are shown in parentheses. Right Angle Connector Cordsets Y96E-43RD❑ 26.5 (1.04) 14.67 (0.57) Aluminum coupling nut Silver-plated copper contacts 2 m (6.56 ft) length for Y96E-43RD2 5 m (16.40 ft) length for Y96E-43RD5 10 m (32.81 ft) length for Y96E-43RD10 ■ CORNER CUBE REFLECTORS E39-L7 Reflector Adapter for E39-R1 Reflector E39-R1 Reflector (included with E3S-AR❑❑) 7.5 (0.30) 2.7 (0.11) Two 3.5 (0.14) dia. 39.3 (1.55) 34 (1.34) 34 (1.339) 7 (0.276) 12 (0.47) 3.2 (0.13) Nut (M5) 59.9 52 (2.36) (2.07) 59 (2.32) 52 (2.05) M5 Spring washer (M5) 1.6 (0.06) 8 (0.32) Two M3 11 E3S-A E3S-A ■ CORNER CUBE REFLECTORS (continued) E39-R3 Optional Reflector Dimensions with E39-L54 Mounting Bracket (included) 4.5 11 6 29 (1.14) 3.4 13.7 3.4 20 14° 7 18.45 0.2 22.9 20 0.2 11 (0.43) Two M3 34.8 25.4 34 16 (0.63) 38 38 (1.50) 41.8 25.4 ± 0.1 Two M3 19.3 34 (1.33) 10.1 1.2 1.2 1.2 E39-R4 Optional Mini-reflector 13.7 4 2 4.9 9.7±0.1 23 19±0.1 4 1.4 Two, 2.2 dia. 2 E39-RSA Optional Adhesive-backed Reflector E39-RSB Optional Adhesive-backed Reflector 40 38 35 33 0.7 0.7 35 33 10 8 Four 1R Reflective surface Adhesive tape side Four 1R ■ OPTICAL AXIS CONFIRMATION REFLECTOR 15.9 9.7 E39-R5 for E3S-A Sensors 11.7 7.9 11.6 Bracket clips to the front of E3S-A receiver 59.9 25 11.2 40.9 12 7.5 Reflective surface Adhesive tape side E3S-A E3S-A ■ SLITS AND FILTERS E39-S46 Slits E39-E6 Mutual Interference Filter Kit for through-beam sensors contains 0.5 mm, 1 mm and 2 mm wide slits and mounting frame. 11.6 A 6.8 2.1 11.6 6.8 9.7 13.6 21.4 or 11.1 21.4 A = Slit width 2.1 ■ MOUNTING SPACER FOR CONNECTOR-TYPE SENSORS E39-L60 Spacer 6.5 33 20 11.75 2.5 6.5 11.75 3.4 dia. 5 2.5 3.4 dia. 5 ■ MOUNTING BRACKETS (supplied with sensors) E39-L70 Mounting Bracket E39-L69 Mounting Bracket 10.7 10.7 16.5 3.2 7.2 16.5 7.2 3.2 20 4.8 5 3.1 3.6 7.2 Four mounting holes 41.7 20 30 10.7 1.2 10.7 1.2 Two, M3 x 12 screws 20 Two, M3 x 12 screws 13 E3S-A E3S-A ■ E39-L59 OPTIONAL VERTICAL MOUNTING BRACKET 10 40 17 12 10.5 20 6.5 57.3 74.3 Two mounting holes 15.7 Mounting bracket (E39-L59) 3.6 7 21 5.5 3.2 6.2 18 3.2 3.2 20 10.5 20 Two, M3 x 12 screws 1.3 34.5 ■ E39-G2 SENSITIVITY ADJUSTER KNOB 8 dia. 0.8 1 12.6 7 dia. ■ MOUNTING BRACKET NOTCH Each mounting bracket slot has a notch to provide a center position for aligning the sensor parallel to the bracket. This ensures that the beam is aligned with the mounting surface. E3S-A Base of mounting bracket Optical axis Mounting direction 14 Bracket can move in this direction Optical axis lock hole (M3) E3S-A E3S-A Operation ■ SENSITIVITY ADJUSTMENT Steps Step 1 Step 2 Step 3 Function Determine Position A Determine Position B Adjust to optimum setting Sensing Condition Sensing object Sensitivity adjuster B Max STABILITY (green) Procedure Max Min ON OFF Sensing object Sensing object A Min Indicators Photoelectric sensor Photoelectric sensor Photoelectric sensor Place target at the desired sensing distance. Set sensitivity adjuster to the minimum scale position, and gradually increase sensitivity by turning the sensitivity adjuster clockwise until the Light Incident indicator (red LED) turns ON. Position A designates the point at which the LED has turned ON. STABILITY (green) B Min Max OFF ON OFF OFF LIGHT (red) A LIGHT (red) STABILITY (green) Remove the target. Starting from the maximum scale position, gradually decrease sensitivity by turning the sensitivity adjuster counterclockwise until the Light Incident indicator (red LED) turns OFF. Position B designates the point at which the LED has turned OFF. LIGHT (red) Set the sensitivity indicator to the position between Positions A and B (in some cases, Positions A and B are opposite of the above example). The photoelectric sensor will then work normally if the stability indicator (green) is lit with and without the target. If it is not lit, stable operation cannot be expected, in which case a different detection method should be applied. Unlike conventional photoelectric sensors, the variation in the sensitivity of E3S photoelectric sensors is minimal. This means the sensitivity can be adjusted on only a single photoelectric sensor, and then the adjusters on the other photoelectric sensors can be set to the same scale position. There is no need to adjust the sensitivity of each photoelectric sensor individually. ■ TIMER AND TURBO SWITCH E3S Sensors equipped with the self-diagnostic feature incorporates an OFF-delay timer that can be adjusted within range of 0 to 100 ms. The emitter of the through-beam sensor with the self-diagnostic feature incorporates a turbo switch. When this switch is on, the intensity of the red LED light source can be increased to make a brighter spot. The OFF-delay time adjuster of the retroreflective and the 20-cm diffuse reflective sensor is used as a turbo switch. When the adjuster is pressed, it functions as a turbo switch to automatically increase the power of the light source to create a brighter light spot. Do not press the adjuster when turning it. Turbo Function (Turbo Switch) With the turbo function switched ON, the light spot is visible even at a distance of 20 cm (7.87 in), making it easy to check the sensing position and the angle of the optical axis. 1. After using the turbo function, readjust the OFF-delay time that had been set, since the OFF-delay time could have been changed when the turbo switch (which is on the OFFdelay time adjuster) was pressed. 2. Press the OFF-delay time adjuster to switch ON the turbo function with a maximum force of 1 kg and within a maximum period of 3 minutes. (The photoelectric sensor, however, will not malfunction even if the turbo function is switched on for more than 3 minutes.) The turbo function is effective with the turbo switch pressed, and the function is reset automatically when released. With Turbo Switch ON Normal Operating Condition Visible spot PUSH Sensitivity adjuster The OFF-delay time adjuster is used as a turbo switch (black) 15 E3S-A E3S-A Self-Diagnostic Function With this function, the E3S-A sensor checks changes in environmental conditions (especially a change in the ambient temperature) and self-diagnoses the resistance against the changes. The result is shown by the indicators or an output signal. Amount of incident light Incident light indicator (red) 1.2 or more With light incident (red indicator: ON) Indicator Green Indicator Green Red 1.0 to 1.2 Green Red 0.8 to 1.0 Without light incident (red indicator: OFF) Selfdiagnostic function Stable operating — state with incident light: Stable operation is expected in the rated temperature range with the green indicator ON. Conditional operating state with incident light: Stable operation is expected if the temperature fluctuation is within ±10% of the primary temperature. Self-diagnostic example — The selfThe optical axis misaligned by vibration. diagnostic alarm output alerts the user to this Light decreased by dust. state if it Dust continues for 0.3 s. With light leakage (through-beam and retroreflective sensors) Green Red Sensing object Light reflected from the floor or the background (diffuse reflective sensors) Sensing object With the influence of external noise Noise 0.8 or less Green Red Stable operating — state with no incident light: Stable operation is expected in the rated temperature range with the green indicator ON. — ■ EXTERNAL DIAGNOSTIC INPUT FUNCTION To switch the emission off, short-circuit the gray (pink) and the black (blue) cords of the emitter of the E3S-AT❑ or the E3S-AR❑ with the NPN output feature. For the E3S-AR❑ with the PNP output feature, short-circuit the gray (pink) and the red (brown) cords. Red (Brown) + V Light emission No emission NOTE: IEC colors are shown in parentheses. 16 OFF (with PNP output) Gray (Externaldiagnostic input) OFF (with NPN output) Black (Blue) 0 V Red (Brown) + V ON (with PNP output) Gray (Pink) (Externaldiagnostic input) ON (with NPN output) Black (Blue) 0 V E3S-A E3S-A ■ SLITS FOR THROUGH-BEAM SENSORS E39-S46 Slit Set Using slits allows smaller objects to be detected and reduces the sensing distance. Slit width Sensing distance 0.5 mm 0.5 m (1.64 ft) 1 mm 1.1 m (3.61 ft) 2 mm 2.4 m (8.20 ft) 2 mm Metal cover Slit (0.5 mm or 1 mm) Min. object size 0.5 mm (0.02 in) 1 mm (0.04 in) 2 mm (0.08 in) Use the rubber attachment with the metal cover if a slit width of 2 mm is required. Insert the 0.5- or 1-mm slit between the metal cover and rubber attachment if a slit width of 0.5 or 1 mm is desired. These slits fit into the rubber attachment. Rubber attachment Arrow indicating position of optical axis Notches to hold cover E3S-A NOTE: Apply the slit to the lens of the photoelectric sensor marked with an arrow indicating the position of the optical axis (apply it to the bottom lens of horizontal sensors and the top lens of vertical sensors). ■ OPTICAL AXIS CONFIRMATION REFLECTOR E39-R5 Use this attachment when the set distance is long and adjustment is mechanically difficult with a sensing object. Attach the reflector to the receiver (refer to the figure). Look at the reflector from right behind the emitter. The reflector should be bright with red light when the optical beam strikes the reflector. If the emitter has a turbo function, the reflector looks brighter with the function switched on. Eye E39-R5 Receiver Optical axis confirmation reflector Emitter When the reflector is removed, the light beam strikes the receiver. ■ ADJUSTER CAP AND OPTIONAL E39-G2 SENSITIVITY ADJUSTER KNOB Adjuster Cap (Supplied with each sensor) In order to prevent the sensitivity or OFF-delay time that has been set from changing accidentally, cover the adjusters with the adjuster cap (enclosed). E39-G2 Adjuster Knob To temporarily use the knob to adjust the sensitivity of the photoelectric sensor, insert side A into the shaft of the sensitivity adjuster. To snap the adjuster onto the sensor, push side B onto the sensitivity knob. (A) Aduster cap Press the adjuster cap until this face touches the name plate on the sensor. Aduster (B) ■ E39-E6 MUTUAL INTERFERENCE FILTER Emitter A set of 4 filters are sold together for two through-beam models (for 2 each of emitters and receivers). The arrow printed on the cover indicates the direction of polarization. By attaching the filters opposite to each other in polarization to the emitters and the receivers (refer to the figure) in rows, mutual interference can be prevented (in any case, the filter attached to an emitter and to the corresponding receiver must be the same in direction of polarization or the photoelectric sensor will not function). Receiver Be aware of the direction of polarization. 17 E3S-A E3S-A NOTE: DIMENSIONS ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. Omron Europe B.V. EMA-ISD, tel:+31 23 5681390, fax:+31 23 5681397, http://www.eu.omron.com/ema Cat. No. CEDSAX2 18 3/97 Specifications subject to change without notice. Printed in the U.S.A.