RECOM RP40

Features
●
●
●
●
●
●
●
●
●
2:1 Wide Input Voltage Range
40 Watts Output Power
1.6kVDC Isolation
UL Certified
Fixed Operating Frequency
Six-Sided Continuous Shield
Design Meet Safety Standard
Standard 50.8 x50.8x10.2mm Package
Efficiency to 90%
Selection Guide 12V, 24V and 48V Input Types
Part Number
Input
Range
VDC
Output
Voltage
VDC
Output
Current
mA
Input (4)
Current
mA
Efficiency(5) Capacitive(6)
Load max.
%
µF
RP40-121.5SG
9-18
1.5
8000
1351
78
45000
RP40-121.8SG
9-18
1.8
8000
1579
80
37700
RP40-122.5SG
9-18
2.5
8000
2137
82
27000
RP40-123.3SG
9-18
3.3
8000
2750
84
21000
RP40-1205SG
9-18
5
8000
4065
86
13600
RP40-1212SG
9-18
12
3333
4065
86
2360
RP40-1215SG
9-18
15
2666
4015
87
1510
RP40-241.5SG
18-36
1.5
8000
649
81
45000
RP40-241.8SG
18-36
1.8
8000
759
83
37700
RP40-242.5SG
18-36
2.5
8000
1029
85
27000
RP40-243.3SG
18-36
3.3
8000
1325
87
21000
RP40-2405SG
18-36
5
8000
1961
89
13600
RP40-2412SG
18-36
12
3333
2048
88
2360
RP40-2415SG
18-36
15
2666
1985
89
1510
RP40-481.5SG
36-75
1.5
8000
321
82
45000
RP40-481.8SG
36-75
1.8
8000
375
84
37700
RP40-482.5SG
36-75
2.5
8000
508
86
27000
RP40-483.3SG
36-75
3.3
8000
655
88
21000
RP40-4805SG
36-75
5
8000
969
90
13600
RP40-4812SG
36-75
12
3333
1000
89
2360
RP40-4815SG
36-75
15
2666
992
89
1510
RP40-1212DG
9-18
±12
±1800
4444
85
±1200
RP40-1215DG
9-18
±15
±1400
4321
85
±750
RP40-2412DG
18-36
±12
±1800
2169
87
±1200
RP40-2415DG
18-36
±15
±1400
2108
87
±750
RP40-4812DG
36-75
±12
±1800
1084
87
±1200
RP40-4815DG
36-75
±15
±1400
1054
87
±750
POWERLINE
DC/DC-Converter
RP40S_D_TG
Series
40 Watt
Single, Dual,
Positive Dual &
Triple Output
UL-60950-1 Certified
for Triple Output continued on next page
Description
The RP40-xxxxG Series of DC/DC Converters are fully certified to EN 60950: 2000. This makes them
ideal for all
Telecom and safety applications where approved isolation is required.
They also meet UL 1950 and CSA 950 standards.
www.recom-international.com
July-2006
275
POWERLINE
RP40-S_D_TG
Series
DC/DC-Converter
Selection Guide 12V, 24V and 48V Input Types
Part Number
Input
Range
VDC
Output
Voltage
VDC
RP40-123.305DG
9-18
3.3 / 5
RP40-243.305DG
18-36
3.3 / 5
Input (4) Efficiency(5) Capacitive(6)
Current
Load max.
mA
%
µF
Output
Current
mA
4A / 4A (total 8A)(15) 3416
85
11000 / 6800
1689
86
11000 / 6800
4A / 4A (total 8A)
823
88
11000 / 6800
6000 / ±400
3063
84
13000 / ±330
(15)
(15)
4A / 4A (total 8A)
RP40-483.305DG
36-75
3.3 / 5
RP40-123.312TG
9-18
3.3 / ±12
RP40-123.315TG
9-18
3.3 / ±15
6000 / ±300
3000
84
13000 / ±110
RP40-120512TG
9-18
5 / ±12
6000 / ±400
4024
86
6800 / ±330
RP40-120515TG
9-18
5 / ±15
6000 / ±300
3963
86
6800 / ±110
RP40-243.312TG
18-36
3.3 / ±12
6000 / ±400
1512
85
13000 / ±330
RP40-243.315TG
18-36
3.3 / ±15
6000 / ±300
1481
85
13000 / ±110
RP40-240512TG
18-36
5 / ±12
6000 / ±400
1989
87
6800 / ±330
RP40-240515TG
18-36
5 / ±15
6000 / ±300
1958
87
6800 / ±110
RP40-483.312TG
36-75
3.3 / ±12
6000 / ±400
747
86
13000 / ±330
RP40-483.315TG
36-75
3.3 / ±15
6000 / ±300
732
86
13000 / ±110
RP40-480512TG
36-75
5 / ±12
6000 / ±400
982
88
6800 / ±330
RP40-480515TG
36-75
5 / ±15
6000 / ±300
967
88
6800 / ±110
Derating-Graph (Ambient Temperature)
RP40-4805SG
125
100
Output Power (%)
75
50
Natural Convection
25
0
-40 -25 -10 0
50 60
70 80 90 100
Ambient Temperature Range (°C)
Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a
part-number not shown here please contact our technical customer service at [email protected]
276
July-2006
www.recom-international.com
RP40-S_D_TG
Series
POWERLINE
DC/DC-Converter
92
91
90
89
88
87
86
85
84
83
82
RP40-4805SG
RP40-4805SG
Efficiency VS Input Voltage
Efficiency VS Output Load
Efficiency (%)
Efficiency (%)
Typical Characteristics
36
42
48
54
60
66
72
75
94
92
90
88
86
84
82
80
75
70
65
1
2
3
4
5
6
7
8
Output Load (A)
Input Voltage (V)
Specifications (typical at nominal input and 25°C unless otherwise noted)
Input Voltage Range
Under Voltage Lockout
12V nominal input
24V nominal input
48V nominal input
12V input DC-DC ON
DC-DC OFF
24V input DC-DC ON
DC-DC OFF
48V input DC-DC ON
DC-DC OFF
Input Filter (see Note 13)
L-C Type
Input Voltage Variation dv/dt
(Complies with ETS300 132 part 4.4)
Input Surge Voltage (100 ms max.)
12V Input
24V Input
48V Input
Input Reflected Ripple (nominal Vin and full load see Note 3)
Start Up Time (nominal Vin and constant resistor load)
Remote ON/OFF (see Note 7)
( Positive logic )
Remote OFF input current
Output Power
Output Voltage Accuracy (full Load and nominal Vin)
Voltage Adjustability
Minimum Load
Line Regulation (low line, high line at full load)
9-18VDC
18-36VDC
36-75VDC
9VDC
8VDC
17.8VDC
16VDC
36VDC
34VDC
5V/ms max
36VDC
50VDC
100VDC
40mAp-p
DC-DC ON
DC-DC OFF
Nominal input
25ms typ.
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
2.5mA
Single & Dual
Triple Main
Auxiliary
40W max.
±1%
±1%
±5%
Single and Dual Positive
Dual and Triple
Single & Dual
±10%
0%
10% of full load
±0.5%
Triple Main
±1%
Triple Auxiliary
±5%
continued on next page
www.recom-international.com
July-2006
277
RP40-S_D_TG
Series
POWERLINE
DC/DC-Converter
Specifications (typical at nominal input and 25°C unless otherwise noted)
Load Regulation (10% to 100% full load see Note 9 and 10)
Cross Regulation (Note 11)
Ripple and Noise (20MHz bandwith)
(Measured with a 1004pF/50V MLCC)
(see Note 12)
Single
Dual
Triple Main
Auxiliary
Triple Main
Dual / Triple Auxiliary
Single 1.5, 1.8, 2.5, 3.3, 5V
Single 12, 15V
Dual 12V
Dual 15V
RP40-xx3.305DG
RP40-xxxxxxTG
Temperature Coefficient
Transient Response (25% load step change)
Over Voltage Protection
Zener diode clamp (only single)
±0.5%
±1%
±2%
±5%
±1%
±5%
50mVp-p
75mVp-p
120mVp-p
150mVp-p
100mVp-p
50 / 75mVp-p
±0.02%/°C max.
1.5, 1.8, 2.5, 3.3V
5V
12V
15V
Over Load Protection (% of full load at nominal Vin)
300µs
3.9V
6.2V
15V
18V
150% max.
Short Circuit Protection
Hiccup, automatic recovery
Efficiency
see „Selection Guide“ table
Isolation Voltage
1600VDC min.
Isolation Resistance
1 GΩ min.
Isolation Capacitance
1000pF max.
Operating Frequency (see Note 14)
Approved to Safety Standards
300kHz typ.
Single,Triple
Dual
Operating Temperature Range
-40°C to +85°C(with derating)
Maximum Case Temperature
Storage Temperature Range
Thermal Impedance (see Note 8)
UL 1950, EN60950
EN60950
100°C
Natural convection
Heat Sink with 20LFM
Heat Sink with 500LFM
Thermal Shock
-55°C to +105°C
9.2°C/Watt
8.5°C/Watt
2.8°C/Watt
MIL-STD-810D
Vibration
10-55Hz, 2G, 30 Min. along X, Y and Z
Relative Humidity
5% to 95% RH
Case Material
Nickel plated copper
Base Material
Non-conductive black plastic FR4
Potting Material
Conducted Emissions (see Note 16)
Radiated Emissions
ESD
Radiated Immunity
Fast Transient
Surge
Conducted Immunity
Epoxy (UL94-V0)
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Weight
60g
Dimensions
50.8 x 50.8 x 10.2mm
1398 x 103 hours
MTBF (see Note 2)
278
Level A
Level A
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
Perf. Criteria 2
July-2006
www.recom-international.com
RP40-S_D_TG
Series
POWERLINE
DC/DC-Converter
Notes :
1. Maximum output deviation is 10% inclusive of remote sense and trim. If remote sense is not being used, the +Vsense should be connected to its
corresponding +OUTPUT and likewise the sense should be connected to its corresponding -OUTPUT
2. BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
3. Simulated source impedance of 12µH. 12µH inductor in series with +Vin.
4. Maximum value at nominal input voltage and full load of standard type.
5. Typical value at nominal input voltage and full load.
6. Test by minimum Vin and constant resistor load.
7. The ON/OFF control pin voltage is referenced to negative input.
8. Heat sink is optional and P/N: 7G-0026A.
9. The triple output required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not
damage these devices,however they may not meet all listed specification.
10. Load regulation for triple output:
Main output(V1):10 to 100% with 10% to 100% balanced on auxiliaries.
Auxiliary outputs(V2 and V3):10% to 100% balanced on all outputs.
11.Cross regulation for triple output:
Main output 100% load, auxiliary 100%,other auxiliary25% to 100%.
Auxiliary outputs(V2 and V3):main output 100% load, auxiliary 100%, other auxiliary
25% to 100% or main output 25%,auxiliary 25%,other auxiliary 25% to 100%.
12.The models of RP40-XX3.305DG are specified with a 1uF ceramic output capacitors.
13.An external filter capacitor is required for normal operation. The capacitor should be capable of handing 1A ripple current for 48V/24V models.
RECOM suggest: Nippon chemi-con KMF series, 220µF/100V, ESR 90m Ω.
14.Operating frequency for dual output: master (5Vo) 300KHz slave (3.3Vo) 500KHz.
15.Any condition of dual output (3.3V/5V) rated Iout current, not to exceed 8A of total output currents. The product safety approval pending.
16.See application notes for EMI-filtering.
Package Style and Pinning (mm)
3rd angle
projection
50.80
50.80
10.20
0.70
dia.
1.0
5.6
Pin Connections
45.70
4
5
5.10
1
2
Bottom View
15.30
28.20
3
6
7
12.70
2.5 5.10
7.6
Pin #
Single
1
+Vin
2
-Vin
3
CTRL
4
NC
5
-Sense (Note1)
6
+Sense (Note1)
7
+Vout
8
-Vout
9
Trim
NC = No Connection
Dual
+Vin
-Vin
CTRL
No Pin
+Vout
Com
Com
-Vout
Trim
Triple
Dual Positive
+Vin
+Vin
-Vin
-Vin
CTRL
CTRL
+Aux
3.3V
Com
3.3V RTN(Com)
-Aux
NC
+Vout
NC
-Vout(Com)
5V
NC
5V RTN(Com)
Pin Pitch Tolerance ±0.35 mm
15.20
20.30
8
External Output Trimming
Output can be externally trimmed by using the method
shown below.
( ) for dual output trim
9
8(8)
Trim Up
9(9)
RD
RU
9(9)
www.recom-international.com
July-2006
Trim Down