SUMIDA CLS126

General Power Transformer < SMD Type : CLS Series>
Type: CLS 126
◆ Product Description
・13.7×12.5mm Max.(L×W),7.5mm Max. Height.
・In addition to the typical versions of parameters shown here,
custom designs are available to meet your exact requirements.
◆ Feature
・Magnetically shielded construction.
・Max. Operating frequency 500kHz.
Max Operating Power 3.7W (500kHz),2.5W(300kHz),1.1W(100kHz).
・Ideally used in Multiple Output, used as power choke.
・RoHS Compliance
◆ Dimensions (mm)
1 2.0 ± 0 .5
5
6
1
10
12 .2 ± 0. 5
7 .5 Ma x.
◆ Schematics (Bottom)
2.5 2.5 2.5 2.5 ±0.2
12 . 0 ±0 . 5
1 3 .2 ±0 . 5
0 . 6 ±0 . 2
1 4.0 ± 0 .5
◆ Land Pattern (mm)
3
8
2
9
S 1
2. 5
7
2. 5
4
2. 5
6 S
2. 5
5
1. 5
2. 0
10
“ S” indicates winding start.
13.1
◆ Specification
Sample No.
Inductance (6-10)
1kHz/1V
D.C.R. (6-10)
@ 20℃
Hi-pot
(1,5-6,10)
6320-T042
1.1mH±30%
2.60Ω Max.
DC 500V/1 Min.
Please refer to the sales offices on our website for a representative near you
www.sumida.com
1/1