HALOGEN Subminiature Radial Leaded, Time-Delay Fuses HF FREE SR-5 Series Pb Agency Information • KC: SU05011-9001 3.15A~6.3A, SU05011-9002 1~2.5A, SU05011-9003 40mA~100mA, SU05011-9004 125mA~800mA • PSE+JET: JET1641-31007-1001 1~5A, JET1641-31007-1002 6.3A • CCC: 2009010207370507 40mA~4A • CQC: CQC09012037502 5A, 6.3A • SEMKO: 1023113 40mA~6.3A • cURus: Guide JDYX2, File E306920&E19180 and Guide JDYX8, File E306920&E19180 • VDE: File122052, 40020046 Radial Leaded Device Electrical Characteristics Rated 1.5 xIn 2.1 xIn 2.75 xIn 4 xIn 10 xIn Current min max min max min max min max 100mA-6.3A 1 hr 2 min 400 mS 10 Sec 150 mS 3 Sec 20 mS 150 mS Description • Radial leaded time-delay thru-hole fuse • Designed to IEC 60127-3, Sheet 4 • Internationally accepted for primary and secondary overcurrent protection • Place directly into PCB or plug into BK/PCS holder • High inrush withstand capability • Compatible with leaded and lead-free reflow and wave solder Specifications • Solderability: EIA-186-9E Method 9 • High frequency vibration: MIL-STD-202F, Method 201A • Operating temperature: -40°C to +85°C • Soldering heat resistance: 260°C, 10 Sec. max (IEC 60068-2-20) Ordering • Specify product and packaging code (i.e., SR-5-1A-AP) Specifications Part Number SR-5-100mA SR-5-125mA SR-5-160mA SR-5-200mA SR-5-250mA SR-5-315mA SR-5-400mA SR-5-500mA SR-5-630mA SR-5-800mA SR-5-1A SR-5-1.25A SR-5-1.6A SR-5-2A SR-5-2.5A SR-5-3.15A SR-5-4A *SR-5-5A *SR-5-6.3A Voltage Rating AC 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 Interrupting Rating (amps) @ Rated Voltage 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 35 40 50 63 Typical DC Cold Resistance (Ω) 2.37 1.6 1.02 0.94 0.66 0.43 0.285 0.242 0.154 0.112 0.085 0.061 0.043 0.031 0.024 0.018 0.012 0.010 0.008 Typical Melting** I2t (@1mS) 0.015155 0.026783 0.039097 0.168832 0.24778 0.2772 0.771618 2 3.5 6.5 7.5 13 24 30 45 57 80 95.4 200 Voltage Drop mV @ 20°C Rated Current 288.5 238 196.5 215.5 185 152 127 143.5 113 104.5 100 91 102 74.5 72.5 70.25 62 57.5 60.85 VDE x x x x x x x x x x x x x x x x x x x Agency Information SEMKO cURus CCC KC-Mark PSE x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x x CQC x x x x CQC x x * Conducting Path min. 0.2mm2 ** I2t value for 100mA to 400mA is measured at 100ln. I2t value for 500mA to 6.3A is measured at 10In. 0711 BU-SB11806 Page 1 of 3 Data Sheet 4347 Time-Current Curves 0711 BU-SB11806 Page 2 of 3 Data Sheet 4347 PCS Mounting Socket (RoHS compliant) • Available as option. Specify catalog number BK/PCS (in bulk 100 per bag) ( Dimensions – Packaging Information – mm [in] ) 0.03" (0.76mm) 0.30" (7.62mm) 0.20" (5.08mm) 0.095" (2.41mm) 0.29" (7.37mm) 0.12" ± 0.01" (3.05mm ± 0.25mm) Land Pattern 5.08 ± 0.2mm Ø 1.0 ± 0.1mm Packaging Code Packaging Code Suffix -AP, -AP -BK, -BK1, -BK2 Description Ammo-pack taped 1,000 per box (see Packaging Information for lead configurations) In bulk 200 per bag (see Packaging Information for lead configurations) The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant injury to the user. © 2011 Cooper Bussmann www.cooperbussmann.com 0711 BU-SB11806 Page 3 of 3 Data Sheet 4347