EPCOS B59300M1180A070

PTC thermistors
Motor protection, triple sensors
Series/Type:
Date:
B59300
March 2006
© EPCOS AG 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
Sensors
Motor protection, triple sensors
M1300
Applications
Thermal protection of winding in electric
motors
Limit temperature monitoring
Dimensional drawing
Features
Thermistor pellets with insulating
encapsulation in series connection
(triple sensor)
Low-resistance type, steep R/T curve
Silver-plated and PTFE-insulated AWG 26
litz wires
Characteristics for nominal threshold
temperatures TNTT = 90 up to 160 °C
conform with DIN 44082
Color coding of litz wires to DIN 44082,
connecting wires in yellow
UL approval to UL 1434 (file number
E69802)
RoHS-compatible
Dimensions in mm
Delivery mode
Bulk
General technical data
Max. operating voltage
Max. measuring voltage
Rated resistance
Insulating test voltage
Thermal threshold time
Operating temperature range
Operating temperature range
(TA = 0 ... 40 °C)
Vmax
(TA = 25 °C ... TNTT +23 K) Vmeas,max
(VPTC ≤ 2.5 V)
RR
Vins
ta
(V ≤ Vmeas,max)
Top
(V = Vmax)
Top
30
7.5
≤300
2.5
<3
25/ TNTT +23
0/+40
VDC
VDC
Ω
kVAC
s
°C
°C
Electrical specifications and ordering codes
TNTT
°C
R
(TNTT ∆T)
(VPTC ≤ 2.5 V)
Ω
R
(TNTT + ∆T)
(VPTC ≤ 2.5 V)
Ω
R
(TNTT + 15 K)
(VPTC ≤ 7.5 V)
Ω
R
(TNTT + 23 K)
(VPTC ≤ 2.5 V)
Ω
Ordering code
≤ 1710
≤ 1710
≤ 1710
≤ 1650
≥ 1710
≥ 1710
≥ 1710
≥ 3990
≥ 12 k
≥ 30 k
≥ 30 k
≥ 30 k
-
B59300M1060A070
B59300M1070A070
B59300M1080A070
B59300M1090A070
∆T = 5 K
60
70
80
90
Please read Important notes and
Cautions and warnings at the end of this document.
Page 2 of 8
Sensors
Motor protection, triple sensors
TNTT
°C
100
110
120
130
140
145
150
155
160
∆T = 7 K
170
180
190
M1300
R
(TNTT ∆T)
(VPTC ≤ 2.5 V)
Ω
≤ 1650
≤ 1650
≤ 1650
≤ 1650
≤ 1650
≤ 1650
≤ 1650
≤ 1650
≤ 1650
R
(TNTT + ∆T)
(VPTC ≤ 2.5 V)
Ω
≥ 3990
≥ 3990
≥ 3990
≥ 3990
≥ 3990
≥ 3990
≥ 3990
≥ 3990
≥ 3990
R
(TNTT + 15 K)
(VPTC ≤ 7.5 V)
Ω
≥ 12 k
≥ 12 k
≥ 12 k
≥ 12 k
≥ 12 k
≥ 12 k
≥ 12 k
≥ 12 k
≥ 12 k
R
(TNTT + 23 K)
(VPTC ≤ 2.5 V)
Ω
-
Ordering code
≤ 1710
≤ 1710
≤ 1710
≥ 1710
≥ 1710
≥ 1710
-
≥ 30 k
≥ 30 k
≥ 30 k
B59300M1170A070
B59300M1180A070
B59300M1190A070
Color coding of litz wires (to DIN 44081)
TNTT
°C
Color
60
70
80
90
100
110
120
130
140
145
150
155
160
170
180
190
white/grey
white/brown
white/white
green/green
red/red
brown/brown
grey/grey
blue/blue
white/blue
white/black
black/black
blue/black
blue/red
white/green
white/red
black/grey
Please read Important notes and
Cautions and warnings at the end of this document.
Page 3 of 8
B59300M1100A070
B59300M1110A070
B59300M1120A070
B59300M1130A070
B59300M1140A070
B59300M1145A070
B59300M1150A070
B59300M1155A070
B59300M1160A070
Sensors
Motor protection, triple sensors
M1300
Characteristics (typical)
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
Please read Important notes and
Cautions and warnings at the end of this document.
Page 4 of 8
Sensors
Motor protection, triple sensors
M1300
Characteristics (typical)
PTC resistance RPTC versus PTC temperature TPTC
(measured at low signal voltage)
Please read Important notes and
Cautions and warnings at the end of this document.
Page 5 of 8
Sensors
Motor protection, triple sensors
M1300
Cautions and warnings
General
EPCOS thermistors are designed for specific applications and should not be used for purposes
not identified in our specifications, application notes and data books unless otherwise agreed
with EPCOS during the design-in-phase.
Ensure suitability of thermistor through reliability testing during the design-in phase. The
thermistors should be evaluated taking into consideration worst-case conditions.
Storage
Store thermistors only in original packaging. Do not open the package before storage.
Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative
humidity ≤75% annual mean, maximum 95%, dew precipitation is inadmissible.
Avoid contamination of thermistors surface during storage, handling and processing.
Avoid storage of thermistor in harmful environment with effect on function on long-term
operation (examples given under operation precautions).
Use thermistor within 6 months after delivery.
Handling
PTCs must not be dropped. Chip-offs must not be caused during handling of PTCs.
Components must not be touched with bare hands. Gloves are recommended.
Avoid contamination of thermistor surface during handling.
Soldering
Use rosin-type flux or non-activated flux.
Insufficient preheating may cause ceramic cracks.
Rapid cooling by dipping in solvent is not recommended.
Complete removal of flux is recommended.
Mounting
Electrode must not be scratched before/during/after the mounting process.
Contacts and housing used for assembly with thermistor have to be clean before mounting.
Especially grease or oil must be removed.
When PTC thermistors are encapsulated with sealing material, the precautions given in chapter
"Mounting instructions", "Sealing and potting" must be observed.
When the thermistor is mounted, there must not be any foreign body between the electrode of
the thermistor and the clamping contact.
The minimum force of the clamping contacts pressing against the PTC must be 10 N.
During operation, the thermistor’s surface temperature can be very high. Ensure that adjacent
components are placed at a sufficient distance from the thermistor to allow for proper cooling at
the thermistors.
Ensure that adjacent materials are designed for operation at temperatures comparable to the
surface temperature of thermistor. Be sure that surrounding parts and materials can withstand
this temperature.
Avoid contamination of thermistor surface during processing.
Please read Important notes and
Cautions and warnings at the end of this document.
Page 6 of 8
Sensors
Motor protection, triple sensors
M1300
Operation
Use thermistors only within the specified temperature operating range.
Use thermistors only within the specified voltage and current ranges.
Environmental conditions must not harm the thermistors. Use thermistors only in normal
atmospheric conditions. Avoid use in deoxidizing gases (chlorine gas, hydrogen sulfide gas,
ammonia gas, sulfuric acid gas etc), corrosive agents, humid or salty conditions.Contact with
any liquids and solvents should be prevented.
Be sure to provide an appropriate fail-safe function to prevent secondary product damage
caused by abnormal function (e.g. use VDR for limitation of overvoltage condition).
Please read Important notes and
Cautions and warnings at the end of this document.
Page 7 of 8
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application.
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar
with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out
in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications
in which the malfunction or failure of a passive electronic component could endanger human
life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured
by means of suitable design of the customer application or other action taken by the customer
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by
third parties in the event of malfunction or failure of a passive electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as “hazardous”). Useful information on this will be found in our
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more
detailed questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be
available.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association
(ZVEI).
7. The trade names EPCOS, EPCOS-JONES, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,
PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are
trademarks registered or pending in Europe and in other countries. Further information will
be found on the Internet at www.epcos.com/trademarks.
Page 8 of 8