TruStability® Board Mount Pressure Sensors: NSC Series– Uncompensated/Unamplified DESCRIPTION The TruStability NSC Series-Uncompensated/Unamplified is a piezoresistive silicon pressure sensor offering a ratiometric analog output for reading pressure over the specified full scale pressure span and temperature range. Additionally, the NSC Series offers numerous package styles and mounting options, making it easier for the device manufacturer to integrate the product into their application. The NSC Series is both unamplified and uncompensated. It offers infinite resolution on the pressure signal. Frequency response is limited only by the end user’s system. The sensor will operate as specified from -40 C to 85 C [-40 F to 185 F]. These sensors measure absolute, differential, and gage pressures. The absolute versions have an internal vacuum reference and an output value proportional to absolute pressure. Differential versions allow application of pressure to either side of the sensing diaphragm. Gage versions are referenced to atmospheric pressure and provide an output proportional to pressure variations from atmosphere. These products are ideal for those customers who want to do their own compensation, calibration, and amplification in order to make use of the maximum resolution of the bare sensor output, leveraging a custom algorithm required for the application. The NSC Series sensors are intended for use with noncorrosive, non-ionic gases, such as air and other dry gases and for non-corrosive, non-ionic liquids. All products are designed and manufactured according to ISO 9001. The NSC Series allows customers the flexibility of selfcalibration while still benefiting from the industry-leading stability, accuracy, and repeatability that the Honeywell TruStability® Pressure Sensors provide. FEATURES AND BENEFITS (=competitive differentiator) Industry-leading long-term stability: Even after long-term use and thermal extremes, these sensors perform substantially better relative to stability than any other pressure sensor available in the industry today: Minimizes system calibration needs and maximizes system performance Helps support system uptime by eliminating the need to service or replace the sensor during its application life Industry-leading accuracy: Extremely tight accuracy of ±0.25 %FSS BFSL: Reduces software needs to correct system inaccuracies, minimizing system design time Supports system accuracy and warranty requirements Helps to optimize system uptime FEATURES AND BENEFITS (=competitive differentiator) (continued) Extremely low power consumption (operating supply voltage as low as 1.8 Vdc): Modular, flexible design with numerous package styles, pressure ports, and options simplify Reduces power consumption integration into the device manufacturer’s application Provides extended battery life Promotes energy efficiency Single side wet media option allows the end customer to use one port of the sensor with Low operating voltage condensing humidity or directly with non-corrosive Sensitive: Meets specified pressure level requirements, liquid media providing enhanced sensitivity and accuracy over the range Small size: Miniature 10 x 10 mm [0.39 x 0.39 in] Virtually insensitive to mounting orientation, allowing for package is very small when compared to most board flexibility of use with the application mount pressure sensors Ratiometric analog output Occupies less area on the PCB Infinite resolution Typically allows for easy placement on crowded Fast response time PCBs or in small devices RoHS compliant Repeatability: Provides excellent repeatability, high Absolute, differential and gage types accuracy and reliability under many demanding Pressure ranges from 1 psi to 150 psi (60 mbar to 10 bar) conditions Also available in the HSC Series and the SSC Series which are fully compensated and calibrated with amplified analog or 2 digital I C or SPI outputs Industry-leading flexibility: POTENTIAL APPLICATIONS (=focus applications) Medical: Industrial: Respiratory breathing circuits: Nebulizers Spirometers Patient monitoring Pneumatic components: Valves Pumps Actuators Flow/pressure control: Therapeutic hospital beds Pneumatic systems: HVAC transmitters Automated pneumatic assembly equipment Pneumatic operator control systems Gas collection/delivery: Hospital gas supply Oxygen concentrators Gas collection/delivery: Industrial gas supply Precise sampling/gas flow: Blood analysis Gas chromatography Analytical instrument sampling systems Precise sampling/gas flow: Barometry Gas chromatography Analytical instrument sampling systems 1 Table 1. Absolute Maximum Ratings Parameter Supply voltage (Vsupply) ESD susceptibility (human body model) Storage temperature Soldering time and temperature: Lead solder temperature (SIP, DIP) Peak reflow temperature (SMT) 2 www.honeywell.com/sensing Min. -12.0 3 -40 [-40] Max. 12.0 85 [185] 4 s max. at 250 °C [482 °F] 15 s max. at 250 °C [482 °F] Unit Vdc kV C [ F] Table 2. Operating Specifications Parameter 2 Supply voltage (Vsupply) Supply current (at 5.0 Vdc supply) 4 Specified temperature range Startup time 5 Accuracy Min. 1.8 Max. 12.0 2 85 [185] 5 0.25 -40 [-40] Table 3. Environmental Specifications Parameter Humidity Vibration Shock 7 Life Solder reflow Table 4. Wetted Materials Parameter Covers Substrate Adhesives Electronic components Typ. 3 5.0 1.5 Unit Vdc mA C [ F] ms 6 %FSS BFSL Characteristic 0% to 95% RH, non-condensing MIL-STD-202F, Curve AK (20.7 g random) MIL-STD-202F, Method 213B, Condition F 1 million pressure cycles minimum J-STD-020-C 8 Port 1 (Pressure Port) high temperature polyamide alumina ceramic epoxy, RTV ceramic, silicon Port 2 (Reference Port) high temperature polyamide alumina ceramic epoxy, RTV silicon, glass, gold, solder Notes: 1. Absolute maximum ratings are the extreme limits the device will withstand without damage. 2. Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage. 3. Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure. 4. The specified temperature range is the temperature range over which the sensor will produce an output proportional to pressure within the specified performance limits. 5. Accuracy: The maximum deviation in output from a Best Fit Straight Line (BFSL) fitted to the output measured over the pressure range at 25 °C [77 °F]. Includes all errors due to pressure non-linearity, pressure hysteresis, and non-repeatability. 6. Full Scale Span (FSS) is the algebraic difference between the output signal measured at the maximum (Pmax.) and minimum (Pmin.) limits of the pressure range. (See Figure 1 for ranges.) 7. Life may vary depending on specific application in which sensor is utilized. 8. Contact Honeywell Customer Service for detailed material information. CAUTION PRODUCT DAMAGE Ensure liquid media is applied to Port 1 only; Port 2 is not compatible with liquids. Ensure liquid media contains no particulates. All TruStability sensors are dead-ended devices. Particulates can accumulate inside the sensor, causing damage or affecting sensor output. Recommend that the sensor be positioned with Port 1 facing downwards; any particulates in the system are less likely to enter and settle within the pressure sensor if it is in this position. Ensure liquid media does not create a residue when dried; build-up inside the sensor may affect sensor output. Rinsing of a dead-ended sensor is difficult and has limited effectiveness for removing residue. Ensure liquid media are compatible with wetted materials. Non-compatible liquid media will degrade sensor performance and may lead to sensor failure. Failure to comply with these instructions may result in product damage. PATENTS Protected by one or more of the following patents: 7531426, 5360521, 7216547, 7677109; App 20110107839. Honeywell Sensing and Control 3 Figure 1. Nomenclature and Order Guide NSC _ _ _ N _ _ _ _ _ U N V Series Supply Voltage V = Constant Package D = DIP (Dual Inline Pin) M = SMT (Surface Mount Technology) S = SIP (Single Inline Pin) Compensation N = Uncompensated Amplification U = Unamplified Pressure Port (* indicates not available) DIP SMT NN = No ports NN = No ports SIP NN = No ports AA = Dual axial barbed ports, opposite sides * * AN = Single axial barbed port AN = Single axial barbed port AN = Single axial barbed port LN = Single axial barbless port LN = Single axial barbless port LN = Single axial barbless port * * FF = Fastener mount, dual axial barbed ports, opposite sides * * FN = Fastener mount, single axial barbed port * * GN = Ribbed fastener mount, single axial barbed port * * RN = Single radial barbed port RN = Single radial barbed port RR = Dual radial barbed ports, same side RR = Dual radial barbed ports, same side RR = Dual radial barbed ports, same side DR = Dual radial barbed ports, opposite sides DR =Dual radial barbed ports, opposite sides DR = Dual radial barbed ports, opposite sides * HH = Fastener mount, dual radial barbed ports, same side * * HN = Fastener mount, single radial barbed port * * MN = Manifold mount, outer diameter seal * * SN = Manifold mount, inner diameter seal Note: 9. See Table 5 for an explanation of sensor pressure types. 4 www.honeywell.com/sensing 1 psi to 150 psi Absolute 015PA = 0 psi to 15 psi 030PA = 0 psi to 30 psi 060PA = 0 psi to 60 psi 100PA = 0 psi to 100 psi 150PA = 0 psi to 150 psi Differential 001PD = ±1 psi 005PD = ±5 psi 015PD = ±15 psi 030PD = ±30 psi 060PD = ±60 psi 100PD = ±100 psi 150PD = ±150 psi Gage 001PG = 0 psi to 1 psi 005PG = 0 psi to 5 psi 015PG = 0 psi to 15 psi 030PG = 0 psi to 30 psi 060PG = 0 psi to 60 psi 100PG = 0 psi to 100 psi 150PG = 0 psi to 150 psi NB = Fastener mount, dual axial ports, same side RN = Single radial barbed port * Pressure Range9 Options N = No special options 60 mbar to 10 bar Absolute 001BA = 0 bar to 1 bar 1.6BA = 0 bar to 1.6 bar 2.5BA = 0 bar to 2.5 bar 004BA = 0 bar to 4 bar 006BA = 0 bar to 6 bar 010BA = 0 bar to 10 bar Differential 060MD = ±60 mbar 100MD = ±100 mbar 160MD = ±160 mbar 250MD = ±250 mbar 400MD = ±400 mbar 600MD = ±600 mbar 001BD = ±1 bar 1.6BD = ±1.6 bar 2.5BD = ±2.5 bar 004BD = ±4 bar 006BD = ±6 bar 010BD = ±10 bar Gage 060MG = 0 mbar to 60 mbar 100MG = 0 mbar to 100 mbar 160MG = 0 mbar to 160 mbar 250MG = 0 mbar to 250 mbar 400MG = 0 mbar to 400 mbar 600MG = 0 mbar to 600 mbar 001BG = 0 bar to 1 bar 1.6BG = 0 bar to 1.6 bar 2.5BG = 0 bar to 2.5 bar 004BG = 0 bar to 4 bar 006BG = 0 bar to 6 bar 010BG = 0 bar to 10 bar Figure 2. Completed Catalog Listing Example NSCSANN100PGUNV Nominal 25 °C Output vs Pressure 20 18 Output (mV/V) 16 NSCSANN100PGUNV SIP package, AN pressure port, no options, 100 psi gage, analog output, unamplified, uncompensated, constant voltage 14 12 10 8 6 4 2 0 0 20 40 60 80 100 Pressure (psi) Table 5. Pressure Types Pressure Type Absolute Differential Gage Description Output is proportional to the difference between applied pressure and a built-in reference to vacuum. Reference pressure is absolute zero pressure (full vacuum). Output is proportional to the difference between the pressures applied to each port. (Port 1 Port 2) Reference pressure is Port 1 = Port 2. Output is proportional to the difference between applied pressure and atmospheric (ambient) pressure. Reference pressure is atmospheric pressure. 015PA 0 15 psi 30 60 N/A -6.0 030PA 0 30 psi 60 120 N/A -6.0 060PA 0 60 psi 100PA 0 100 150PA 0 150 Unit Burst Pressure Offset10 (mV/V) Common Mode Pressure Pressure Range Over Pressure Pressure Range (see Figure 1) Table 6. Pressure Range Specifications for 1 psi to 150 psi Pmin. Pmax. Sensitivity TCO11 (mV/V/Full Scale (%FSS/25 C) Span) Min. Max. Min. Nom. Max. TCS12 (%FSS/25 C) Bridge Resistance13 (kOhm) Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. TCR14 (-40 C to 25 C) (ppm/°C) Min. Max. TCR15 (25 C to 85 C) (ppm/°C) Min. Max. Long-term Stability (1000 hr, 25 °C [77 °F]) (%FSS) Absolute 6.0 10.3 15.0 19.7 -3.6 0.0 3.6 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% 6.0 14.8 19.7 -3.8 0.0 3.8 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% 120 250 N/A -6.0 6.0 10.7 15.2 19.7 -3.5 0.0 3.5 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% psi 250 250 N/A -6.0 6.0 12.6 16.1 -4.1 0.0 4.1 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% psi 250 250 N/A -6.0 6.0 13.6 18.9 24.2 -2.8 0.0 2.8 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% 9.9 9.1 Differential 001PD -1 1 psi 5 20 150 -8.5 3.5 13.0 17.0 -1.1 0.5 1.1 -6.3 -5.0 -3.8 4 5 6 1200 2200 2200 3200 ±0.35% 005PD -5 5 psi 20 40 150 -8.5 3.5 20.0 30.0 40.0 -0.6 0.2 0.6 -6.3 -5.0 -3.8 4 5 6 1200 2200 2200 3200 ±0.35% 015PD -15 15 psi 30 60 150 -7.0 5.3 20.7 31.0 41.4 -0.6 0.3 0.5 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 030PD -30 30 psi 60 120 150 -7.0 5.3 31.0 41.4 51.7 -0.3 0.2 0.3 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 060PD -60 60 psi 120 250 250 -7.0 5.3 34.8 41.4 48.0 -0.3 0.2 0.3 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 100PD -100 100 psi 250 250 250 -7.0 5.3 29.0 34.5 40.0 -0.3 0.3 0.3 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 150PD -150 150 psi 250 250 250 -7.0 5.3 43.4 51.7 60.0 -0.2 0.2 0.2 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 9.0 Gage 001PG 0 1 psi 5 20 150 -8.5 3.5 -2.2 1.0 2.2 -6.3 -5.0 -3.8 4 5 6 1200 2200 2200 3200 ±0.35% 005PG 0 5 psi 20 40 150 -8.5 3.6 10.0 15.0 20.0 -1.0 0.4 1.0 -6.3 -5.0 -3.8 4 5 6 1200 2200 2200 3200 ±0.35% 015PG 0 15 psi 30 60 150 -7.0 5.3 10.3 15.5 20.7 -1.0 0.6 1.0 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 030PG 0 30 psi 60 120 150 -7.0 5.3 15.5 20.7 25.9 -0.6 0.4 0.6 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 060PG 0 60 psi 120 250 250 -7.0 5.3 17.4 20.7 24.0 -0.6 0.4 0.6 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 100PG 0 100 psi 250 250 250 -7.0 5.3 14.5 17.2 20.0 -0.7 0.5 0.7 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 150PG 0 150 psi 250 250 250 -7.0 5.3 21.7 25.9 30.0 -0.6 0.3 0.6 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2200 3200 ±0.25% 4.5 6.5 8.5 Honeywell Sensing and Control 5 Table 7. Pressure Range Specifications for 60 mbar to 10 bar 10 12 TCS (%FSS/25 C) Bridge 13 Resistance (kOhm) TCR (-40 C to 25 C) (ppm/°C) 15 TCR (25 C to 85 C) (ppm/°C) 001BA 0 1 bar 2 4 N/A -6.0 6.0 10.0 14.5 19.0 -3.8 0.0 3.8 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% 1.6BA 0 1.6 bar 4.1 8 N/A -6.0 6.0 7.7 11.4 15.2 -4.9 0.0 4.9 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% 2.5BA 0 2.5 bar 4.1 8 N/A -6.0 6.0 12.0 17.9 23.8 -3.1 0.0 3.1 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% 004BA 0 4 bar 8 17 N/A -6.0 6.0 10.3 14.7 19.0 -3.6 0.0 3.6 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% 006BA 0 6 bar 17 17 N/A -6.0 6.0 7.9 11.0 14.0 -4.8 0.0 4.8 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% 010BA 0 10 bar 17 17 N/A -6.0 6.0 13.2 18.3 23.4 -2.9 0.0 2.9 -7.5 -5.0 -3.0 2.6 3.5 4.4 500 1500 1500 2500 ±0.25% Unit Common Mode Pressure Sensitivity 11 TCO (mV/V/Full Scale (%FSS/25 C) Span) Burst Pressure Offset (mV/V) Over Pressure Pressure Range (see Figure 1) 14 Pressure Range Pmin. Pmax. Min. Max. Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. Min. Nom. Max. Min. Max. Min. Max. Long-term Stability (1000 hr, 25 °C [77 °F]) (%FSS) Absolute Differential 060MD -60 60 mbar 340 1380 10000 -8.5 3.5 7.8 11.3 14.8 -1.3 0.6 1.3 -6.3 -5.0 -3.8 4 5 6 1200 2200 2220 3200 0.35% 100MD -100 100 mbar 340 1380 10000 -8.5 3.5 13.1 18.9 24.7 -0.8 0.3 0.8 -6.3 -5.0 -3.8 4 5 6 1200 2200 2220 3200 0.35% 160MD -160 160 mbar 340 1380 10000 -8.5 3.5 20.9 30.2 39.4 -0.5 0.2 0.5 -6.3 -5.0 -3.8 4 5 6 1200 2200 2220 3200 0.35% 250MD -250 250 mbar 1380 2760 10000 -8.5 3.5 14.5 21.8 29.0 -0.7 0.3 0.7 -6.3 -5.0 -3.8 4 5 6 1200 2200 2220 3200 0.35% 400MD -400 400 mbar 1380 2760 10000 -7.0 5.3 23.2 34.8 46.4 -0.4 0.2 0.4 -6.3 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.35% 600MD -600 600 mbar 2060 4100 10000 -7.0 5.3 12.0 18.0 24.0 -0.8 0.5 0.8 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 001BD -1 1 bar 2 4 10 -7.0 5.3 20.0 30.0 40.0 -0.6 0.3 0.5 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 1.6BD -1.6 1.6 bar 4.1 8 10 -7.0 5.3 24.0 32.0 40.0 -0.4 0.3 0.4 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 2.5BD -2.5 2.5 bar 4.1 8 10 -7.0 5.3 37.5 50.0 62.5 -0.3 0.2 0.3 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 004BD -4.0 4.0 bar 8 17 17 -7.0 5.3 33.6 40.0 46.4 -0.3 0.2 0.3 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 006BD -6.0 6.0 bar 17 17 17 -7.0 5.3 25.2 30.0 34.8 -0.4 0.3 0.4 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 010BD -10.0 10 bar 17 17 17 -7.0 5.3 42.0 50.0 58.0 -0.2 0.1 0.2 -6.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% Gage 060MG 0 60 mbar 340 1380 10000 -8.5 3.5 3.9 5.7 7.4 -2.6 1.1 2.6 -6.3 -5.0 -3.8 4 5 6 1200 2200 2220 3200 0.35% 100MG 0 100 mbar 340 1380 10000 -8.5 3.5 6.5 9.4 12.3 -1.5 0.7 1.5 -6.3 -5.0 -3.8 4 5 6 1200 2200 2220 3200 0.35% 160MG 0 160 mbar 340 1380 10000 -8.5 3.5 10.4 15.1 19.7 -1.0 0.4 1.0 -6.3 -5.0 -3.8 4 5 6 1200 2200 2220 3200 0.35% 250MG 0 250 mbar 1380 2760 10000 -8.5 3.5 7.3 10.9 14.5 -1.4 0.6 1.4 -6.3 -5.0 -3.8 4 5 6 1200 2200 2220 3200 0.35% 400MG 0 400 mbar 1380 2760 10000 -7.0 5.3 11.6 17.4 23.2 -0.9 0.4 0.9 -6.3 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.35% 600MG 0 600 mbar 2060 4100 10000 -7.0 5.3 6.0 12.0 -1.7 1.0 1.7 -8.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.35% 001BG 0 1 bar 2 4 10 -7.0 5.3 10.0 15.0 20.0 -1.0 0.6 1.0 -8.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 1.6BG 0 1.6 bar 4.1 8 10 -7.0 5.3 12.0 16.0 20.0 -0.8 0.5 0.8 -8.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 2.5BG 0 2.5 bar 4.1 8 10 -7.0 5.3 18.8 25.0 31.3 -0.6 0.4 0.5 -8.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 004BG 0 4 bar 8 17 17 -7.0 5.3 16.8 20.0 23.2 -0.6 0.4 0.6 -8.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 006BG 0 6 bar 17 17 17 -7.0 5.3 12.6 15.0 17.4 -0.8 0.6 0.8 -8.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 010BG 0 10 bar 17 17 17 -7.0 5.3 21.0 25.0 29.0 -0.5 0.4 0.5 -8.0 -5.0 -3.8 2.4 3 5.5 1200 2200 2220 3200 0.25% 9.0 Notes: 10. Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or “zero”. 11. TCO (Thermal Effect on Offset): The deviation in offset due to changes in temperature over the specified temperature range, relative to offset measured at 25 C. 12. TCS (Thermal Effect on Span): The deviation in full scale span due to changes in temperature over the specified temperature range, relative to full scale span measured at 25 C. 13. Bridge Resistance: The resistance of the device measured across the power supply leads. 14. TCR (Thermal Coefficient of Resistance): The deviation in bridge resistance due to changes in temperature over the specified temperature range, relative to bridge resistance measured at 25 C. Table 8. Pinout for DIP and SMT Packages Output Type Pin 1 Pin 2 analog GND OUTPUT+ Table 9. Pinout for SIP Packages Output Type Pin 1 analog GND 6 www.honeywell.com/sensing Pin 3 Vsupply Pin 4 OUTPUT- Pin 2 OUTPUT+ Pin 5 NC Pin 6 NC Pin 3 Vsupply Pin 7 NC Pin 8 NC Pin 4 OUTPUT- Figure 3. DIP Pressure Port Dimensional Drawings (For reference only: mm [in]) DIP NN: No ports 8 7 6 DIP AN: Single axial barbed port 0,25 [0.010] 5,44 [0.214] 5 PORT 1 13,75 [0.541] 10,0 [0.39] 8 PORT 2 13,35 [0.525] 6,99 [0.275] 7 6 5 0,25 [0.010] 7,95 [0.313] 10,0 [0.39] 6,2 [0.24] 13,35 [0.525] 6,99 PORT 2 [0.275] 4,93 DIA. [0.194] PORT 1 1 2 3 1 4 2 9,24 [0.364] 10,85 [0.427] 2,54 TYP. [0.100] 3 4 9,24 [0.364] 11,21 [0.441] 2,54 TYP. [0.100] 8X 0,46 [0.018] 8X 0,46 [0.018] DIP LN: Single axial barbless port 5,80 [0.228] 8 7 6 DIP RN: Single radial barbed port 0,25 [0.010] 10,0 [0.39] 5 8 7 6 2,47 DIA. [0.097] PORT 2 6,99 [0.275] 13,35 [0.525] 0,25 [0.010] 5,80 [0.228] 5 10,0 [0.39] 4,2 [0.17] 13,35 [0.525] 6,99 PORT 2 [0.275] PORT 1 PORT 1 1 2 3 1,93 DIA. [0.076] 4 9,24 [0.364] 2,54 TYP. [0.100] 1 2 3 4 2,54 TYP. [0.100] 11,21 [0.441] 13,75 [0.541] 6,95 [0.274] 9,24 [0.364] 11,21 [0.441] 1,00 [0.039] 8X 0,46 [0.018] 8X 0,46 [0.018] DIP RR: Dual radial barbed ports, same side 4,0 [0.16] 8 7 6 5 PORT 1 PORT 1 PORT 2 ,25 [0.010] 6,16 [0.242] 13,35 [0.525] 6,99 PORT 2 [0.275] DIP DR: Dual radial barbed ports, opposite sides 15,76 [0.620] 10,0 [0.39] 2X 1,93 DIA. [0.076] 8 7 6 5 2 3 4 2,54 TYP. [0.100] 9,24 [0.364] 11,21 [0.441] 10,0 [0.39] 2X 1,93 DIA. [0.076] 6,99 PORT 2 [0.275] PORT 1 4,65 [0.183] 1 0,25 [0.010] 6,16 [0.242] 13,35 [0.525] PORT 1 PORT 2 1 2 3 9,24 [0.364] 4 2,54 TYP. [0.100] 3,78 [0.149] 11,21 [0.441] 3,78 [0.149] 8X 0,46 [0.018] 8X 0,46 [0.018] Honeywell Sensing and Control 7 Figure 4. SMT Pressure Port Dimensional Drawings (For reference only: mm [in]) SMT NN: No ports 8 7 6 SMT AN: Single axial barbed port 13,75 [0.541] 10,0 [0.39] 5,44 [0.214] 5 8 6 5 10,0 [0.39] 7,95 [0.313] 13,4 [0.53] 6,99 PORT 2 [0.275] PORT 1 7 4,93 DIA. [0.194] PORT 2 13,4 [0.53] 6,99 [0.275] PORT 1 1 2 3 4 8X 0,46 [0.018] 4,80 [0.189] 6,41 [0.252] 2,54 TYP. [0.100] 1 5,80 [0.228] 7 6 3 4 4,80 [0.189] 6,77 [0.266] 2,54 TYP. [0.100] SMT LN: Single axial barbless port 8 2 SMT RN: Single radial barbed port 10,0 [0.394] 5 8X 0,46 [0.018] 8 7 6 5,80 [0.228] 5 2,47 DIA. [0.097] 13,35 [0.525] 6,99 PORT 2 [0.275] PORT 1 10,0 [0.39] 4,2 [0.17] 13,3 [0.53] 6,99 PORT 2 [0.275] PORT 1 1,93 DIA. [0.076] PORT 1 1 2 3 1 4 4,80 [0.189] 6,77 [0.266] 2,54 TYP. [0.100] 8X 0,46 [0.018] 2 3 4 4,80 [0.189] 6,77 [0.266] 2,54 TYP. [0.100] 8X 0,46 [0.018] 13,75 [0.541] SMT RR: Dual radial barbed ports, same side 4,0 [0.16] 8 7 6 2X 1,93 DIA. [0.076] 13,35 [0.525] 6,99 PORT 2 [0.275] PORT 1 PORT 1 PORT 2 10,0 [0.39] 6,16 [0.242] 5 SMT DR: Dual radial barbed ports, opposite sides 2X 2,93 [0.115] 15,8 [0.62] 8 7 6 2X 1,93 DIA. [0.076] 4,6 [0.18] 1 2 3 4 2,54 TYP. [0.100] 13,4 [0.53] 6,99 [0.275] PORT 2 PORT 1 4,80 [0.189] 6,77 [0.266] 3,78 [0.149] 8 10,0 [0.39] 6,16 [0.242] 5 www.honeywell.com/sensing 8X 0,46 [0.018] 1 2 3 4 2,54 TYP. [0.100] 3,78 [0.149] 4,80 [0.189] 6,77 [0.266] 8X 0,46 [0.018] Figure 5. SIP Package Dimensional Drawings (For reference only: mm [in]) SIP NN: No ports SIP AA: Dual axial barbed ports, opposite sides 10,0 [0.39] 10,0 [0.39] 4,87 [0.192] 10,0 [0.39] PORT 1 22,06 [0.869] 10,0 [0.39] PORT 2 PORT 2 PORT 1 2X 4.93 DIA. [0.194] 15,2 [0.60] 1 2 3 15,2 [0.60] 4 4X 0,51 [0.020] 1 0,25 [0.010] 2 3 2,54 TYP. [0.100] SIP AN: Single axial barbed port 10,0 [0.39] PORT 1 0,25 [0.010] 10,0 [0.39] 13,75 [0.541] 10,0 [0.39] PORT 2 2,47 DIA. [0.097] 15,2 [0.60] 15,2 [0.60] 2 3 4 4X 0,51 [0.020] PORT 2 PORT 1 4.93 DIA. [0.194] 1 2,54 TYP. [0.100] SIP LN: Single barbless port 13,75 [0.541] 10,0 [0.39] 4 4X 0,51 [0.020] 1 0,25 [0.010] 2,54 TYP. [0.100] 2 3 4 0,25 [0.010] 4X 0,51 [0.020] 2,54 TYP. [0.100] SIP FF: Fastener mount, dual axial barbed ports, opposite sides 27,20 [1.071] 29,48 [1.161] 23,12 [0.910] 10,44 [0.411] 17,78 [0.700] PORT 2 PORT 1 2X 3.94 DIA. [0.155] 2X 4,78 DIA. [0.188] 20,16 [0.794] 1 0,25 [0.010] 4X 0,51 [.020] 2 3 4 2,54 TYP. [0.100] SIP FN: Fastener mount, single axial barbed port 29,48 [1.161] 16,38 [0.645] 23,12 [0.910] 17,78 [0.700] PORT 2 2X 3.94 DIA. [0.155] PORT 1 4.78 DIA. [0.188] 20,16 [0.794] 1 4X 0,51 [0.020] 0,25 [0.010] 2 3 4 2,54 TYP. [0.100] Honeywell Sensing and Control 9 Figure 5. SIP Package Dimensional Drawings (continued) SIP GN: Ribbed fastener mount, single axial barbed port 27,96 [1.101] 21,60 [0.850] 16,51 [0.650] 19,06 [0.750] PORT 2 PORT 1 2X 3,94 DIA. [0.155] 4.78 DIA. [0.188] 10,63 [0.418] 1 0,25 [0.010] 4X 0,51 [0.020] 2 3 4 2,54 TYP. [0.100] SIP NB: Fastener mount, dual axial ports, same side 27,31 [1.075] 25,3 [0.996] 21,60 [0.850] 2X 4,80 DIA. [0.189] PORT 2 2X 3.50 DIA. [0.138] 22,87 [0.900] PORT 1 13 [0.52] 4 3 2 1 0,25 [0.010] 4X 0,51 [0.020] 2,54 TYP. [0.100] SIP RN: Single radial barbed port 10,0 [0.39] 5,80 [0.228] PORT 1 10,0 [0.39] 1,92 DIA. [0.076] PORT 2 15,2 [0.60] 1 2 3 4 4X 0,51 [0.020] 0,25 [0.010] 2,54 TYP. [0.100] SIP RR: Dual radial barbed ports, same side 10,0 [0.39] 6,16 [0.243] PORT 1 10,0 [0.39] PORT 2 2X 1,92 DIA. [0.076] 15,2 [0.60] 1 2 3 4 4X 0,51 [0.020] 10 www.honeywell.com/sensing 0,25 [0.010] 2,54 TYP. [0.100] Figure 5. SIP Package Dimensional Drawings (continued) SIP DR: Dual radial barbed ports, opposite side SIP HH: Fastener mount, dual radial barbed ports, same side 29,62 [1.166] 15,8 [0.62] 10,0 [0.39] 6,16 [0.243] 10,58 [0.416] 6,64 [0.261] 23,12 [0.910] PORT 2 10,0 [0.39] PORT 2 PORT 1 PORT 1 PORT 2 PORT 1 28,96 [1.140] 2X 4.93 DIA. [0.194] 15,2 [0.60] 1 2 3 4 4X 0,51 [0.020] 0,25 [0.010] 11,27 [0.444] 2,54 TYP. [0.100] 4X 0,51 [0.020] SIP HN: Fastener mount, single radial barbed port 23,12 [0.910] 0,25 [0.010] 2 3 4 2,54 TYP. [0.100] SIP MN: Manifold mount, outer diameter seal 7,97 [0.314] 4,78 DIA. [0.188] 1 5,36 [0.211] PORT 2 PORT 1 15,24 DIA. [0.600] PORT 1 28,96 [1.140] PORT 2 12,5 [0.49] 2X 3,94 DIA. [0.155] 11,27 [0.444] 1 4X 0,51 [0.020] 4X 0,51 [0.020] 2 3 4 0,25 [0.010] 0,25 [0.010] 1 2 3 4 2,54 TYP. [0.100] 2,54 TYP. [0.100] SIP SN: Manifold mount, inner diameter seal PORT 2 12,57 [0.495] 5,1 [0.20] PORT 1 13,11 [0.516] 15,6 [0.61] 1 4X 0,51 [0.020] 2 3 4 2,54 TYP. [0.100] Honeywell Sensing and Control 11 WARNING WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. DO NOT USE this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: [email protected] Internet: www.honeywell.com/sensing Phone and Fax: While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Asia Pacific Europe Latin America USA/Canada Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com/sensing 008221-1-EN IL50 GLO Printed in USA July 2011 © 2011 Honeywell International Inc. +65 6355-2828; +65 6445-3033 Fax +44 (0) 1698 481481; +44 (0) 1698 481676 Fax +1-305-805-8188; +1-305-883-8257 Fax +1-800-537-6945; +1-815-235-6847 +1-815-235-6545 Fax