MITSUBISHI ML501P73

LASER DIODES
ML5xx73 LD SERIES
FOR DISPLAY SYSTEM
ML501P73
TYPE
NAME
DESCRIPTION
FEATURES
• High Output Power: 1.0W (Pulse)
Mitsubishi ML501P73 is a high-power, highly
efficient semiconductor laser diode which provides
emission wavelength of 638 nm and standard light
output of 1.0W (pulse) and 0.5W (CW).
This LD has broad-stripe structure which enables
high output power.
0.5W (CW)
• High Efficiency: 1.0mW/mA (typ.)
• Visible Light: 638nm (typ.)
• φ5.6mm Capless PKG
APPLICATION
• Display system, Bio-medical
ABSOLUTE MAXIMUM RATINGS (Note 1)
Symbol
Parameter
Po
Light output power
Conditions
Ratings
Unit
CW
0.5
W
Pulse Duty≤33%,
frequency≥50Hz
1.0
W
VRL
Reverse voltage
-
2
V
Tc
Case temperature
-
-5 ~ +40
°C
Tstg
Storage temperature
-
-40 ~ +100
°C
Note1: The maximum rating means the limitation over which the laser should not be operated even instant time.
This does not mean the guarantee of its lifetime. As for the reliability, please refer to the reliability report issued
by Quality Assurance Section, HF & Optical Semiconductor Division, Mitsubishi Electric Corporation.
ELECTRICAL/OPTICAL CHARACTERISTICS (Tc=25°C)
Symbol
Parameter
Test conditions
Min.
Typ.
Max
Unit
Ith
Threshold current
CW
90
170
210
mA
Iop
Operating current
CW, Po=0.5W
500
650
800
mA
Vop
Operating voltage
CW, Po=0.5W
1.9
2.2
2.6
V
η
Slope efficiency
CW, Po=0.5W
0.8
1.0
1.4
mW/mA
λp
Peak wavelength
CW, Po=0.5W
632
638
644
nm
θ//
Beam divergence angle
(parallel)
CW, Po=0.5W
1
7.5
15
°
θ⊥
Beam divergence angle
(perpendicular)
CW, Po=0.5W
25
35
45
°
Specifications are subject to change without notice.
TLDE-P1245
(1/5)
LASER DIODES
ML5xx73 LD SERIES
FOR DISPLAY SYSTEM
OUTLINE DRAWINGS
Y
+0.1
0.4-0
0
φ5.6-0.03
Dimensions in mm
1.0±0.1
ML501P73
1.5±0.1
X
1.77(typical)
φ2.0±0.3
(P.C.D)
1.2±0.1
2.3MAX
3.8(typical)
(1)
0.5(typical)
0.4±0.1
LD
CASE
(3)
(2)
0.4MAX
φ5.6mm Capless
6.5±1.0
ML501P73
φ1.2MAX
3-φ0.45±0.1
(2) (3) (1)
Typical Characteristics of ML501P73
Tc=15 25 35 40℃
Tc=15 25 35 40℃
1.0
0.4
Light Output Power [W]
Light Output Power [W]
0.5
0.3
0.2
0.1
0.8
0.6
0.4
0.2
Pulse
f=50Hz,D=33%
CW
0.0
0
0
200
400
600
800 1000
Current [mA]
Light Output Power vs. Current (CW)
0
500
1000
1500
Current [mA]
2000
Light Output Power vs. Current (Pulse)
Specifications are subject to change without notice.
TLDE-P1245
(2/5)
LASER DIODES
ML5xx73 LD SERIES
FOR DISPLAY SYSTEM
Typical Characteristics of ML501P73
Intensity(a.u.)
Po=0.5W, CW
Tc=25℃
θ∥=7.5°
(FWHM)
θ⊥=35°
(FWHM)
-50 -40 -30 -20 -10 0 10 20 30 40 50
Angle(°)
Far-Field-Patterns
655
Tc=25℃
CW
650
Peak Wavelength(nm)
Peak Wavelength(nm)
655
645
640
635
630
625
~5nm/W
620
Po=0.5W
CW
650
645
640
635
630
625
~0.20nm/℃
620
0
100 200 300 400 500
Light output Power(mW)
600
Peak Wavelength vs. Light Output Power
0
10
20
30
40
Temperature(℃)
50
Peak Wavelength vs. Temperature
Specifications are subject to change without notice.
TLDE-P1245
(3/5)
60
LASER DIODES
ML5xx73 LD SERIES
FOR DISPLAY SYSTEM
Safety precaution for handling optical semiconductor devices
General:
Although manufacturer is always striving to improve the reliability of its products, problems and errors may occur with
semiconductor devices. Hence, it is necessary that user’s own products are designed with full regard to safety by
incorporating redundancy, fire prevention, and error prevention, so any problems or errors with semiconductor device
do not cause accidents, which might result in injury, death, fire, or environmental hazard. The following requirements
must be strictly observed.
Warning!
1. Safety standard of laser devices
Please follow closely to international standard (e.g. IEC 60825-1) or standard of each country (ex. JIS C 6802 in
Japan).
2. Laser characteristics and its danger
When laser device is operated at over-driven condition, low temperature, pulsing mode, and so on, it could emit
higher optical power than absolute maximum rating, and peak optical power might increase in conjunction with
relaxation oscillation. Laser device could lase at different wavelength with different case temperature, or different
output power. Laser devices are deviated on threshold current, operating current, operating voltage, slope efficiency,
peak wavelength, beam divergence, and so on. Not only light output power, but also polarization or far field patterns
might change as operating time goes by. If customers need more information of laser device, please contact Mitsubishi
Electric.
Laser light from each device might seriously injure human eyes and skin. Customer should design and manufacture
carefully their application products based on not only laser light characteristics but also LD characteristics, in order to
avoid human injury. Mitsubishi Electric is not responsible for any accidents that are caused by customer’s products.
If customers plan to release medical or aesthetic products with laser device, they should obtain their government’s
laser safety authorization.
3. Avoid laser light from entering human eyes
In normal operation, semiconductor laser device emits laser light. Laser light entering eyes could cause extreme
damage. Never look against laser beam direction, and never look directly through an optical system such as a lens.
Use an ITV camera to observe laser light. Mitsubishi Electric recommends that customers should explicitly label their
laser products with warning sign of eye injury.
4. Handling of device
Gallium arsenide (GaAs) is used in laser device. To avoid danger, strictly observe the following cautions:
Never place the device in human mouth. Never burn or break the device. Never use any type of chemical treatment to
reduce it to gas or powder. When disposing device, always follow any applicable laws, as well as customer’s internal
waste treatment regulations.
5. Disposal of device
Laser device uses Gallium arsenide (GaAs). It should be disposed as a specially controlled industrial waste, and it
should be separated from general industrial and household wastes, according to any “Law of Wastes and Cleaning”.
Caution!
1. High temperature
During operation device may become hot, therefore do not directly touch it during operation. The device could remain
hot even after power is turned off, so wait until it cools down prior to touching to avoid any burn. Never place any
inflammable substance that may cause fire near the device.
Specifications are subject to change without notice.
TLDE-P1245
(4/5)
LASER DIODES
ML5xx73 LD SERIES
FOR DISPLAY SYSTEM
Handling Cautions for Optoelectronic Devices
1. General
(1-1) The products described in this specification are designed and manufactured for use in general communication
systems or electronic devices, unless their applications or reliability are otherwise specified. Therefore, they are not
designed or manufactured for installation in devices or systems that may affect human life or that are used in social
infrastructure requiring high reliability.
(1-2) When the customer is considering to use the products described in this specification in special applications, such
as transportation systems (automobiles, trains, vessels), medical equipments, aerospace, nuclear power control, and
submarine repeaters or systems, please contact Mitsubishi Electric or an authorized distributor.
2. Storage Conditions
When storing the products, it is recommended to store them following the conditions described below without opening
the packing. Not taking enough care in storing may result in defects in electrical characteristics, soldering quality, visual
appearance, and so on. The main points are described below (if special storage conditions are given to the product in
the specification sheet, they have priority over the following general cautions):
(2-1) Appropriate temperature and humidity conditions, i.e., temperature range between 5~35° C, and humidity
between 45~75 percent RH, should be maintained in storage locations. Controlling the temperature and humidity
within this range is particularly important in case of long-term storage for six months or more.
(2-2) The atmosphere should be particularly free from toxic gases and dust.
(2-3) Do not apply any load on the product.
(2-4) Do not cut or bend the leads of the devices which are to be stored. This is to prevent corrosion in the cut or bent
part of the lead causing soldering problems in the customer’s assembling process.
(2-5) Sudden change in temperature may cause condensation in the product or packing, therefore, such locations
should be avoided for storing. Temperature in storage locations should be stable.
(2-6) Storage conditions for cap-less products shall be stated separately because these products require stricter
controls than package sealed products.
3. Design Conditions and Environment under Use
(3-1) Operation in excess of the absolute maximum ratings can cause permanent damage to the device. The customers
are requested to design not to exceed those ratings even for a short time.
(3-2) Avoid use in locations where water or organic solvents adhere directly to the product, or where there is any
possibility of the generation of corrosive gas, explosive gas, dust, salinity, or other troublesome conditions. Such
environments will not only significantly lower the reliability, but also may lead to serious accidents.
(3-3) Contamination to cap window or LD emitting point by volatile material, such as adhesive, may degrade reliability.
When a customer use adhesive material, we recommend the customer to confirm possible effect before usage.
(3-4) Quality assurance for cap-less products shall be stated separately because these products require more notice in
your line and your products environment than package sealed products.
4. Static Electric Safety Cautions
The optoelectronic devices are sensitive to static electricity (ESD, electro-static discharge). The product can be broken
by ESD. When handling this product, please observe the following countermeasures:
<Countermeasures against Static Electricity and Surge>
To prevent break of devices by static electricity or surge, please adopt the following countermeasures in the assembly
line:
(4-1) Ground all equipments, machinery jigs, and tools in the process line with earth wires installed in them. Take
particular care with hot plates, solder irons and other items for which the commercial power supplies are prone to
leakage.
(4-2) Workers should always use earth bands. Use of antistatic clothing, electric conductive shoes, and other safety
equipment while at work is highly recommended.
(4-3) Use conductive materials for this product’s container, etc.
(4-4) It is recommended that grounding mats be placed on the surfaces of assembly line workbench and the
surrounding floor in work area, etc.
(4-5) When mounting this product in parts or materials which can be electrically charged (printed wiring boards, plastic
products, etc.), pay close attention to the static electricity in those parts. ESD may damage the product.
(4-6) Humidity in working environment should be controlled to be 40 percent RH or higher.
These countermeasures are most general, and there is a need to carefully confirm the line using this product. It is
extremely important to prevent surge, eliminate it rapidly, and prevent it from spreading.
Specifications are subject to change without notice.
TLDE-P1245
(5/5)