LASER DIODES ML5xx73 LD SERIES FOR DISPLAY SYSTEM ML501P73 TYPE NAME DESCRIPTION FEATURES • High Output Power: 1.0W (Pulse) Mitsubishi ML501P73 is a high-power, highly efficient semiconductor laser diode which provides emission wavelength of 638 nm and standard light output of 1.0W (pulse) and 0.5W (CW). This LD has broad-stripe structure which enables high output power. 0.5W (CW) • High Efficiency: 1.0mW/mA (typ.) • Visible Light: 638nm (typ.) • φ5.6mm Capless PKG APPLICATION • Display system, Bio-medical ABSOLUTE MAXIMUM RATINGS (Note 1) Symbol Parameter Po Light output power Conditions Ratings Unit CW 0.5 W Pulse Duty≤33%, frequency≥50Hz 1.0 W VRL Reverse voltage - 2 V Tc Case temperature - -5 ~ +40 °C Tstg Storage temperature - -40 ~ +100 °C Note1: The maximum rating means the limitation over which the laser should not be operated even instant time. This does not mean the guarantee of its lifetime. As for the reliability, please refer to the reliability report issued by Quality Assurance Section, HF & Optical Semiconductor Division, Mitsubishi Electric Corporation. ELECTRICAL/OPTICAL CHARACTERISTICS (Tc=25°C) Symbol Parameter Test conditions Min. Typ. Max Unit Ith Threshold current CW 90 170 210 mA Iop Operating current CW, Po=0.5W 500 650 800 mA Vop Operating voltage CW, Po=0.5W 1.9 2.2 2.6 V η Slope efficiency CW, Po=0.5W 0.8 1.0 1.4 mW/mA λp Peak wavelength CW, Po=0.5W 632 638 644 nm θ// Beam divergence angle (parallel) CW, Po=0.5W 1 7.5 15 ° θ⊥ Beam divergence angle (perpendicular) CW, Po=0.5W 25 35 45 ° Specifications are subject to change without notice. TLDE-P1245 (1/5) LASER DIODES ML5xx73 LD SERIES FOR DISPLAY SYSTEM OUTLINE DRAWINGS Y +0.1 0.4-0 0 φ5.6-0.03 Dimensions in mm 1.0±0.1 ML501P73 1.5±0.1 X 1.77(typical) φ2.0±0.3 (P.C.D) 1.2±0.1 2.3MAX 3.8(typical) (1) 0.5(typical) 0.4±0.1 LD CASE (3) (2) 0.4MAX φ5.6mm Capless 6.5±1.0 ML501P73 φ1.2MAX 3-φ0.45±0.1 (2) (3) (1) Typical Characteristics of ML501P73 Tc=15 25 35 40℃ Tc=15 25 35 40℃ 1.0 0.4 Light Output Power [W] Light Output Power [W] 0.5 0.3 0.2 0.1 0.8 0.6 0.4 0.2 Pulse f=50Hz,D=33% CW 0.0 0 0 200 400 600 800 1000 Current [mA] Light Output Power vs. Current (CW) 0 500 1000 1500 Current [mA] 2000 Light Output Power vs. Current (Pulse) Specifications are subject to change without notice. TLDE-P1245 (2/5) LASER DIODES ML5xx73 LD SERIES FOR DISPLAY SYSTEM Typical Characteristics of ML501P73 Intensity(a.u.) Po=0.5W, CW Tc=25℃ θ∥=7.5° (FWHM) θ⊥=35° (FWHM) -50 -40 -30 -20 -10 0 10 20 30 40 50 Angle(°) Far-Field-Patterns 655 Tc=25℃ CW 650 Peak Wavelength(nm) Peak Wavelength(nm) 655 645 640 635 630 625 ~5nm/W 620 Po=0.5W CW 650 645 640 635 630 625 ~0.20nm/℃ 620 0 100 200 300 400 500 Light output Power(mW) 600 Peak Wavelength vs. Light Output Power 0 10 20 30 40 Temperature(℃) 50 Peak Wavelength vs. Temperature Specifications are subject to change without notice. TLDE-P1245 (3/5) 60 LASER DIODES ML5xx73 LD SERIES FOR DISPLAY SYSTEM Safety precaution for handling optical semiconductor devices General: Although manufacturer is always striving to improve the reliability of its products, problems and errors may occur with semiconductor devices. Hence, it is necessary that user’s own products are designed with full regard to safety by incorporating redundancy, fire prevention, and error prevention, so any problems or errors with semiconductor device do not cause accidents, which might result in injury, death, fire, or environmental hazard. The following requirements must be strictly observed. Warning! 1. Safety standard of laser devices Please follow closely to international standard (e.g. IEC 60825-1) or standard of each country (ex. JIS C 6802 in Japan). 2. Laser characteristics and its danger When laser device is operated at over-driven condition, low temperature, pulsing mode, and so on, it could emit higher optical power than absolute maximum rating, and peak optical power might increase in conjunction with relaxation oscillation. Laser device could lase at different wavelength with different case temperature, or different output power. Laser devices are deviated on threshold current, operating current, operating voltage, slope efficiency, peak wavelength, beam divergence, and so on. Not only light output power, but also polarization or far field patterns might change as operating time goes by. If customers need more information of laser device, please contact Mitsubishi Electric. Laser light from each device might seriously injure human eyes and skin. Customer should design and manufacture carefully their application products based on not only laser light characteristics but also LD characteristics, in order to avoid human injury. Mitsubishi Electric is not responsible for any accidents that are caused by customer’s products. If customers plan to release medical or aesthetic products with laser device, they should obtain their government’s laser safety authorization. 3. Avoid laser light from entering human eyes In normal operation, semiconductor laser device emits laser light. Laser light entering eyes could cause extreme damage. Never look against laser beam direction, and never look directly through an optical system such as a lens. Use an ITV camera to observe laser light. Mitsubishi Electric recommends that customers should explicitly label their laser products with warning sign of eye injury. 4. Handling of device Gallium arsenide (GaAs) is used in laser device. To avoid danger, strictly observe the following cautions: Never place the device in human mouth. Never burn or break the device. Never use any type of chemical treatment to reduce it to gas or powder. When disposing device, always follow any applicable laws, as well as customer’s internal waste treatment regulations. 5. Disposal of device Laser device uses Gallium arsenide (GaAs). It should be disposed as a specially controlled industrial waste, and it should be separated from general industrial and household wastes, according to any “Law of Wastes and Cleaning”. Caution! 1. High temperature During operation device may become hot, therefore do not directly touch it during operation. The device could remain hot even after power is turned off, so wait until it cools down prior to touching to avoid any burn. Never place any inflammable substance that may cause fire near the device. Specifications are subject to change without notice. TLDE-P1245 (4/5) LASER DIODES ML5xx73 LD SERIES FOR DISPLAY SYSTEM Handling Cautions for Optoelectronic Devices 1. General (1-1) The products described in this specification are designed and manufactured for use in general communication systems or electronic devices, unless their applications or reliability are otherwise specified. Therefore, they are not designed or manufactured for installation in devices or systems that may affect human life or that are used in social infrastructure requiring high reliability. (1-2) When the customer is considering to use the products described in this specification in special applications, such as transportation systems (automobiles, trains, vessels), medical equipments, aerospace, nuclear power control, and submarine repeaters or systems, please contact Mitsubishi Electric or an authorized distributor. 2. Storage Conditions When storing the products, it is recommended to store them following the conditions described below without opening the packing. Not taking enough care in storing may result in defects in electrical characteristics, soldering quality, visual appearance, and so on. The main points are described below (if special storage conditions are given to the product in the specification sheet, they have priority over the following general cautions): (2-1) Appropriate temperature and humidity conditions, i.e., temperature range between 5~35° C, and humidity between 45~75 percent RH, should be maintained in storage locations. Controlling the temperature and humidity within this range is particularly important in case of long-term storage for six months or more. (2-2) The atmosphere should be particularly free from toxic gases and dust. (2-3) Do not apply any load on the product. (2-4) Do not cut or bend the leads of the devices which are to be stored. This is to prevent corrosion in the cut or bent part of the lead causing soldering problems in the customer’s assembling process. (2-5) Sudden change in temperature may cause condensation in the product or packing, therefore, such locations should be avoided for storing. Temperature in storage locations should be stable. (2-6) Storage conditions for cap-less products shall be stated separately because these products require stricter controls than package sealed products. 3. Design Conditions and Environment under Use (3-1) Operation in excess of the absolute maximum ratings can cause permanent damage to the device. The customers are requested to design not to exceed those ratings even for a short time. (3-2) Avoid use in locations where water or organic solvents adhere directly to the product, or where there is any possibility of the generation of corrosive gas, explosive gas, dust, salinity, or other troublesome conditions. Such environments will not only significantly lower the reliability, but also may lead to serious accidents. (3-3) Contamination to cap window or LD emitting point by volatile material, such as adhesive, may degrade reliability. When a customer use adhesive material, we recommend the customer to confirm possible effect before usage. (3-4) Quality assurance for cap-less products shall be stated separately because these products require more notice in your line and your products environment than package sealed products. 4. Static Electric Safety Cautions The optoelectronic devices are sensitive to static electricity (ESD, electro-static discharge). The product can be broken by ESD. When handling this product, please observe the following countermeasures: <Countermeasures against Static Electricity and Surge> To prevent break of devices by static electricity or surge, please adopt the following countermeasures in the assembly line: (4-1) Ground all equipments, machinery jigs, and tools in the process line with earth wires installed in them. Take particular care with hot plates, solder irons and other items for which the commercial power supplies are prone to leakage. (4-2) Workers should always use earth bands. Use of antistatic clothing, electric conductive shoes, and other safety equipment while at work is highly recommended. (4-3) Use conductive materials for this product’s container, etc. (4-4) It is recommended that grounding mats be placed on the surfaces of assembly line workbench and the surrounding floor in work area, etc. (4-5) When mounting this product in parts or materials which can be electrically charged (printed wiring boards, plastic products, etc.), pay close attention to the static electricity in those parts. ESD may damage the product. (4-6) Humidity in working environment should be controlled to be 40 percent RH or higher. These countermeasures are most general, and there is a need to carefully confirm the line using this product. It is extremely important to prevent surge, eliminate it rapidly, and prevent it from spreading. Specifications are subject to change without notice. TLDE-P1245 (5/5)