ONSEMI LV8804FVGEVB

SANYO Semiconductors
Test Procedure for the LV8804FVGEVB Evaluation Board
Oscilloscope
CURRENT PROBE
AMPLIFIER1
PROBE
INPUT
OUTPUT
FAN Motor
Function generater
Power supply
Table: Required Equipment
Efficiency
12V-1A
DC 0-VREG
4 channel
Equipment
Power supply
Function generator
Oscilloscope
Current probe
LV8804FV Evaluation Board
Motor
3/26/2012
12V-3W
1
www.onsemi.com
SANYO Semiconductors
Test Procedure:
1. Connect the test setup as shown above.
2. Initial check
Boot up at the VCC = 12V.
CTL=0V(PWM 100%)
Confirm that the motor rotates smoothly and in a right direction.
Switch the FR switch when the motor rotation direction defferent.
3. Booting check (StartUp-mode)
Check whether a booting of a motor is stable. (Booting)
Boot up at the VCC = 6V and 12V.
When CTL voltage vary from 0V to 4V, check to chamge the motor rotation speed.
And then, at each VCC and CTL voltage check whether a motor boots 100 times in 100times.
Check the some waveforms. (Booting waveforms)
Boot up at the VCC =12V.
Check the WO, VO and FG voltage waveform at scope CH1, CH2 and CH3, and the output current
waveform of WO at scope CH4 by the Oscilloscope.
ex) These waveforms are different by each motor.
StartUp-mode
T=0.5s/div
UO
5V/div
FG
5V/div
Current
of UO
1A/div
Turn on the power supply
3/26/2012
2
www.onsemi.com
SANYO Semiconductors
4. Normal rotation check (Regular-Rotation-mode)
Check the some waveforms. (Rotation waveforms)
Supply the VCC=12V.
Check the WO, VO and FG voltage waveform at scope CH1, CH2 and CH3, and the output current
waveform of WO at scope CH4 by the Oscilloscope.
ex) These waveforms are different by each motor.
Regular-Rotation-mode
T=2ms/div
UO
5V/div
FG
5V/div
Current
of UO
1A/div
3/26/2012
3
www.onsemi.com
SANYO Semiconductors
5. Lock detection check (Motor-Lock-mode)
Check the Lock detection behavior. (Lock)
Supply the VCC=12V.
Check the signal of WO, VO and UO is off when stop the Motor by your hand forcibly.
Then, check the WO, VO and FG voltage waveform at scope CH1, CH2 and CH3, and the output
current waveform of WO at scope CH4 by the Oscilloscope.
ex) These waveforms are different by each motor.
Motor-Lock-mode
T=0.5s/div
UO
5V/div
FG
5V/div
Current
of UO
1A/div
The Motor is stopped
6. Checking result
A sample of checking result is shown below.
VCC
12V
6V
3/26/2012
CTL voltage
0V
1.5V
2.5V
0V
1.5V
2.5V
Booting
100/100 OK
100/100 OK
100/100 OK
100/100 OK
100/100 OK
100/100 OK
Rotation speed (rpm)
-
4
Rotation waveforms
OK
OK
OK
OK
OK
OK
Io
value
value
value
value
value
value
Lock
OK
OK
OK
OK
OK
OK
www.onsemi.com