RECOM RAZ

Features
●
●
●
●
●
●
Regulated
Converters
ECONOLINE
1:1 Input Range
Efficiency up to 69%
1kVDC and 2kVDC Isolation Option
1W SMD Package
-40°C to +85°C Operating Temperature Range
Continuous Short Circuit Protection
DC/DC-Converter
Selection Guide
Part
Number
SMD
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
Efficiency
(typ.)
Capacitive
Load
(max.)
RAZ-0505S*
5
5
200
67%
2200µF
RAZ-1205S*
12
5
200
68%
2200µF
RAZ-2405S*
24
5
200
69%
2200µF
1 Watt SMD
Single Output
* add Suffix “/H“ for 2kVDC/1min. Isolation - e.g. RAZ-0505S/H
* add Suffix “-R“ for tape & reel packing - e.g. RAZ-1205S-R, RAZ-2405S/H-R
Specifications (measured at TA = 25°C, nominal input voltage and rated output current unless otherwise specified
Input Voltage Range
±10% max.
Output Voltage Accuracy
-1% typ., ±5% max.
Line Voltage Regulation
(low line to high line at max. load)
1% max.
Load Voltage Regulation
(10% to 100% full load)
1% max.
Output Ripple and Noise (20MHz BW)
50mVp-p typ., 75mVp-p max.
Operating Frequency (Vin=nominal input)
Specifications valid for 10% minimum load only
Isolation Voltage
(tested for 1 minute)
Isolation Voltage
1000 VDC
(tested for 1 second)
1250 VDC
H-Suffix
(testet for 1 minute)
2000 VDC
H-Suffix
(tested for 1 second)
6pF typ., 10pF max.
Isolation Resistance
(Viso=500V)
Derating-Graph
10GΩ min.
Short-Circuit Protection
continuous
Operating Temperature Range
(Ambient Temperature)
-40°C to +85°C
Storage Temperature
-55°C to +125°C
Relative Humidity
95% RH
100
1.6g
Detailed Information see
Application Notes chapter "MTBF"
using MIL-HDBK 217F
3914 x 10³ hours
using MIL-HDBK 217F
855 x 10³ hours
Certifications
EN General Safety
EN60950-1, 2nd Edition
Report: MDD1112018 + RM1112018
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under
1 second without damage to the converter.
80
Output Power (%)
Package Weight
EN Medical Safety
RAZ
2500 VDC
Isolation Capacitance
}
(*/H suffix)
see Selection Guide
Minimum Load = 0%
MTBF (+85°C)
EN-60950-1 Certified
EN-60601-1 Certified*
20kHz min. / 35kHz typ. / 60kHz max.
Efficiency at Full Load
MTBF (+25°C)
RoHS
2011/65/EU
6/6
60
40
30
20
0
Safe Operating Area
-40
0
50
100
85
Operating Temperature °C 95
Refer to Application Notes
E-62
REV: 0/2013
www.recom-electronic.com
150
RAZ Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
Efficiency / Load
100
2405
Efficiency %
80
60
0505
40
1205
20
0
0%
20%
40%
80%
60%
Total Output current (%)
100%
Package Style and Pinning
3rd angle
projection
8.70
18.00
7.80
7.20
10.65
1.27x13
Pin Connections
Pin #
Function
1,2
28 27
17 16 15
RECOM
RAZ-XX05S
NC
13
-Vout
14
+Vout
27
-Vin
NC = No Connection
RAZ
9.00
+Vin
12,15~17,28
Pb
12
Unit:
Tolerance:
1.27
0.50 pin width
mm
± 0.25 mm
12 13 14
www.recom-international.com
REV: 0/2013
E-63