EPCOS B88069X6331S102

Switching spark gap
SSG with lead wires
Series/Type:
Ordering code:
SSG03X-1J
B88069X6331****
Version/Date:
Issue 02 / 2009-10-20
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer
PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or
footer when copying the content.
Identification/Classification 1:
(header 1 + top left header bar)
Switching spark gap
Identification/Classification 2:
(header 2 + bottom left header bar)
SSG with lead wires
Ordering code:
(top right header bar)
B88069X6331****
Series/Type:
(top right header bar)
SSG03X-1J
Preliminary data (optional):
(if necessary)
Department:
PPD AB PD / PPD AB PM
Date:
Issue 02 / 2009-10-20
 EPCOS AG 2009. Reproduction, publication and dissemination of this document, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
Switching spark gap
SSG with lead wires
B88069X6331****
SSG03X-1J
Features
Application








Extremely long life time
Stable performance over life
Insensitive performance against variations in
temperature
Very low switching losses
Very short breakdown time
High reliability by robust design
RoHS-compatible
Ignition of HID lamps
Electrical specifications
Nominal breakdown voltage VN
350
V
Initial values 1) 2)
Static breakdown voltage VS
First ignition value VS, FTE after 24 hours in darkness
Following ignition values VS, FIV
 420
290 ... 390
V
V
Electrical life time 3)
Breakdown voltage VB
First ignition value VB, FTE after 24 hours in darkness
Ignition time tI at V0 during life
Following ignition values VB, FIV
 450
 300
290 ... 390
V
ms
V
Switching operations
at + 25 °C
50 000
Ignitions
Test circuit parameters
Open circuit voltage V0
Loading resistance R
Discharge capacitance C
Inductance L
Discharge peak current IP
450
10
680
0.5
~ 500
V
k
nF
µH
A
> 100
 2
 50
200
50
~2
M
%
ns
Hz
mA
g
General technical data
Insulation resistance at 100 V
Early ignition values below 290 V
Breakdown time
Maximum switching frequency
Maximum loading current
Weight
Marking, red positive
350 WWY O
350
WW
Y
O
- Nominal voltage
- Calendar week of production
- Year of production
- Non radioactive
1)
At delivery AQL 0,65 level II, DIN ISO 2859
Fig. 1 and 2
3)
Fig. 3 and 4
PPD AB PD / PPD AB PM
2)
Please read Cautions and warnings and
Important notes at the end of this document.
Issue 02 / 2009-10-20
Page 2 of 5
Switching spark gap
SSG with lead wires
B88069X6331****
SSG03X-1J
Test circuits and explanations
Fig. 1: QC-test circuit (100% outgoing inspection)
I = const
Fig. 2: Explanation of measurands
51k
VS, FTE
VS, FIV
VS
DUT
0,22 F
VN
VS
ICU
- VN
DUT device under test
ICU
ignition control unit (sensitivity 10 ... 30 A)
Discharge current 10 ... 20 mA
Fig. 3: QC-test circuit (sampling inspection at 25 °C)
dVS/dt ~ dVN/dt
Fig. 4: Explanation of measurands
VB, FTE
L
R
VB, FTE
Range of VB, FIV
VB
Early ignition
VN
VO
C
DUT
VB
t
tI
0.5 s
PPD AB PD / PPD AB PM
Please read Cautions and warnings and
Important notes at the end of this document.
3s
Issue 02 / 2009-10-20
Page 3 of 5
Switching spark gap
SSG with lead wires
B88069X6331****
SSG03X-1J
Dimensional drawing in mm
Ordering codes and packing advices
B88069X6331S102 = 100 pcs. on 5 taped stripes
B88069X6331T502 = 500 pcs. on tape and reel
Cautions and warnings


Switching spark gaps may be used only within their specified values.
Damaged switching spark gaps must not be re-used.
PPD AB PD / PPD AB PM
Please read Cautions and warnings and
Important notes at the end of this document.
Issue 02 / 2009-10-20
Page 4 of 5
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for
certain areas of application. These statements are based on our knowledge of typical
requirements that are often placed on our products in the areas of application concerned. We
nevertheless expressly point out that such statements cannot be regarded as binding
statements about the suitability of our products for a particular customer application. As a
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them
than the customers themselves. For these reasons, it is always ultimately incumbent on the
customer to check and decide whether an EPCOS product with the properties described in the
product specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure
before the end of their usual service life cannot be completely ruled out in the current state
of the art, even if they are operated as specified. In customer applications requiring a very high
level of operational safety and especially in customer applications in which the malfunction or
failure of an electronic component could endanger human life or health (e.g. in accident
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the
customer application or other action taken by the customer (e.g. installation of protective circuitry
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or
failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this
publication may contain substances subject to restrictions in certain jurisdictions (e.g.
because they are classed as hazardous). Useful information on this will be found in our Material
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed
questions, please contact our sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this
publication may change from time to time. The same is true of the corresponding product
specifications. Please check therefore to what extent product descriptions and specifications
contained in this publication are still applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently,
we cannot guarantee that all products named in this publication will always be available.
The aforementioned does not apply in the case of individual agreements deviating from the
foregoing for customer-specific products.
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of
the “General Terms of Delivery for Products and Services in the Electrical Industry”
published by the German Electrical and Electronics Industry Association (ZVEI).
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DeltaCap, DSSP,
MiniBlue, MiniCell, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap,
SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K,
ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries.
Further information will be found on the Internet at www.epcos.com/trademarks.
Page 5 of 5