POWERBOX VI-201-IW

5 0 - 2 0 0 W
P C B
M O U N T I N G
C O M P O N E N T S
MODULES
VI 200
Features
•
•
•
•
•
•
•
Inputs: 10 to 400VDC
Output, 1 to 95VDC
UL, CSA, TÜV, VDE, BABT, CF
80–90% efficiency (typical)
ZCS power architecture
Low noise FM control
Booster versions available for expanded power
Specifications
INPUT
Input voltage
Selection Table
A = INPUT VOLTAGE
B = OUTPUT VOLTAGE
Nominal
Range Notes
0= 12V
10–20V (1)
Z = 2V
2 = 15V
1= 24V
21–32V (6)
Y = 3.3V
N = 18.5V
W= 24V
18–36V (4)
0 = 5V
3 = 24V
2= 36V
21–56V (3)
X = 5.2V
L = 28V
3= 48V
42–60V (6)
W = 5.5V
J = 36V
N= 48V
36–76V (6)
V = 5.8V
K = 40V
4= 72V
55–100V (6)
T = 6.5V
4 = 48V
T= 110V
66–160V (4)
R = 7.5V
H = 52V
5= 150V
100–200V (5)
M = 10V
F = 72V
6= 300V
200–400V (6)
1 = 12V
D = 85V
7= 150/300V 100–375V (2)
P = 13.8V
B = 95V
C = PRODUCT GRADE D = OUTPUT POWER/CURRENT
V out ≥5V
V out <5V
E= -10°C to +85°C
Y= 50W
Y= 10A
C= -25°C to +85°C
X= 75W
X = 15A
I= -40°C to +85°C
W= 100W
W = 20A
M= -55°C to +85°C
V= 150W
V = 30A
U= 200W
U = 40A
See table
OUTPUT
PRODUCT GRADE
E, C, I, M
Output voltage
See table
Output power
See table
Set point accuracy
0.5%
Low–high trim voltage
50%–110%
Output ripple pk-pk
1%
Load regulation
0.05%
Line regulation
0.05%
OVP set point
115%–135%
Current limit setting
105%–125%
Remote sense Compensation0.5V
OPERATING
MTBF
>1,000,000 hrs
Efficiency
80%–90%
Isolation input – output
3750V rms
Baseplate operating temp.
85°C
Shutdown temperature
95°C
Thermal shutdown
Yes, C, I, M grades
NOTES:
ENVIRONMENTAL
Cooling
External cooling often required, consult sales
office
(2)
(3)
(4)
(5)
(6)
NOTES: Maximum Output for — (1)
5V Outputs
75W 75W* 100W 150W 150W 200W
>5V Outputs
75W 100W 100W 150W 200W 200W
<5V Outputs
15A 20A 20A 30A 40A 40A
*100W @ 5V (20A), 300V input only.
STANDARDS AND APPROVALS
Safety
UL1950, CSA C22.2 No. 950, TÜV IEC950,
EN60950, VDE 0805
C-Tick
AS/NZS CISPR11 Group 1 Class A
MECHANICAL
Dimensions
117x61x12.7mm
PCB mounting
Yes
Selection Table Guide
VI - 2 [a] [b] - [c] [d]
VI - B [a] [b] - [c] [d] Booster
Note: For RoHS version replace VI with VE.
Mechanical Drawings See page 230
Your dependable power partner – www.powerbox.com.au
229
MODULES
Mechanical Drawings
F U L L A N D J U N I O R S I Z E D M E C H A N I C A L S P E C I F I C AT I O N S
JUNIOR SIZED MODULES
FULL SIZED MODULES
230