MOLEX 0638240100

Extractor Tool for CMX Receptacle Connector
Extractor Tool
Application Tooling
Specification Sheet
Order No. 63824-0100
FEATURES
This Extractor Tool is for opening the Secondary Lock from CMX Receptacle 53 Way, 198009 Series.
This Tool will also assist in closing the secondary lock.
SCOPE
Products: CMX Receptacle Connector Assembly, 53 Way, Right and Left Slide Orientation.
Housing Series No
198009
Housing Order No.
198009-1001 198009-1002 198009-1003 198009-1004
198009-2001 198009-2002 198009-2003 198009-2004
OPERATION:
Opening the (TPA) Secondary Lock
On a CMX receptacle assembly follow the steps below:
1. Insert the extractor tool into the (2) side slots of the (TPA) secondary lock on each sides until it stops. See
Figure 1.
2. While keeping the extractor tool in this position pull down on the sides of the (TPA) secondary lock without
touching the latches. The locking latches should be visible. See Figure 2.
3. Remove the extractor tool and check the position of the TPA.
TPA SECONDARY
LOCK CLOSED
TPA SECONDARY
LOCK OPEN
SLOTS
TPA SECONDARY
LOCKING LATCHES
(BOTH SIDES)
SLOTS
EXTRACTOR
TOOL
Doc No: ATS-638240100
Revision: E
LOCKING
LATCHES OPEN
(BOTH SIDES)
Figure 1
EXTRACTOR TOOL
Release Date: 07-14-10
Revision Date: 06-06-12
Figure 2
UNCONTROLLED COPY
Page 1 of 2
Extractor Tool for CMX Receptacle Connector
Closing the (TPA) secondary lock
On a CMX receptacle assembly, follow the steps below:
Secondary lock can be closed manually or during the final connector check.
This procedure is done after the insertion of all female terminals.
1. Insert the extractor tool into the (2) side slots of the (TPA) secondary lock on each sides. See Figure 3.
2. Push up on the extract tool until the TPA contacts with the edge of the seal and the locking latches click in
place.
3. Make sure there is no space between the TPA and the seal. See Figure 4.
4. Remove the extractor tool.
Note:
One of the functions of the secondary lock (TPA) is to detect if any of the terminals are not fully seated in the
cavities. If the secondary lock does not close, reopen the TPA.
Push on the terminals one at a time to make sure they are locked in place.
Close the secondary lock see step 2 and 3.
Check visually the locking latches are in the correct position.
SEAL PROTECTED BY
A MOVEABLE SKIRT
LOCKING LATCHES
OPEN (BOTH SIDES)
LOCKING LATCHES
CLOSED
(BOTH SIDES)
THE TOOL FINGERS
BOTTOM STOP SHOULD BE
IN CONTACT WITH THE TPA
BEFORE PUSHING ON THE
TPA
Figure 4
TPA SECONDARY
LOCK OPEN
TPA SECONDARY
LOCK CLOSED
Figure 3
EXTRACTOR TOOL
THERE SHOULD BE A
SMALL GAP BETWEEN THE
BOTTOM STOP OF THE
TOOL FINGERS AND THE
TPA
Molex does not offer repair parts for Extractor Tools due to the inexpensive nature of these tools.
CAUTION: Molex specifications are valid only when used with Molex terminals and tooling.
http://www.molex.com
Doc No: ATS-638240100
Revision: E
Release Date: 07-14-10
Revision Date: 06-06-12
UNCONTROLLED COPY
Page 2 of 2