CEL NX5307EK-AZ

NECʼs 1310 nm InGaAsP MQW FP
LASER DIODE IN CAN PACKAGE NX5307 SERIES
FOR 2.5 Gb/s INTRA-OFFICE APPLICATION
FEATURES
• OPTICAL OUTPUT POWER:
PO = 10 mW
• LOW THRESHOLD CURRENT :
ITH = 10 mA
• HIGH SPEED:
tr = 0.2 ns MAX
tf = 0.2 ns MAX
• WIDE OPERATING TEMPERATURE RANGE:
TC = -40 to +85°C
• InGaAs MONITOR PIN-PD
• CAN PACKAGE:
ø5.6 mm
• BASED ON TELCORDIA RELIABILITY
DESCRIPTION
NECʼs NX5307 series is a 1310 nm Multiple Quantum Well
(MQW) structured Fabry-Perot (FP) laser diode with InGaAs
monitor PIN-PD. This device is ideal for Synchronous Digital
Hierarchy (SDH) systems, intra-office STM-16 (I-16), and
ITU-T recommendations.
California Eastern Laboratories
NX5307 SERIES
PACKAGE DIMENSIONS (Units in mm)
BOTTOM VIEW
1
110º±2º
2
4
3
0.3+0.1
-0.0
*1
Focal Point
∆x = ±300 µm
∆y = ±300 µm
PIN CONNECTIONS
2.97±0.2
6.35±0.5
φ 2.0
NX5307EH
LD
2
4– φ 0.45
NX5307EK
1 (Case)
1 (Case)
Reference
Plane
15.0±1.0 1.2±0.1
3.87±0.3
1.0±0.1
0.3+0.1
-0.0
φ 5.6+0.00
-0.03
φ 4.2±0.1
φ 3.55±0.1
PD
3
φ 2.0
*1 Focal Point: A point to get maximum optical output power from fiber.
4
LD
2
4
PD
3
NX5307 SERIES
ORDERING INFORMATION
PART NUMBER
NX5307EH-AZ*
PACKAGE
PIN CONNECTIONS
4-pin CAN with ball lens cap
1
LD
2
PD
NX5307EK-AZ*
4
3
1
LD
2
4
PD
3
Remarks 1. The color of ball lens cap might be observed differently from our can package products.
2. The hermetic test will be performed as AQL 1.0%.
*NOTE:
Please refer to the last page of this data sheet, “Compliance with EU Directives” for Pb-Free RoHS Compliance Infomation.
NX5307 SERIES
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
RATINGS
UNIT
Optical Output Power
Po
20
mW
Forward Current of LD
IF
150
mA
Reverse Voltage of LD
VR
2.0
V
Forward Current of PD
IF
10
mA
Reverse Voltage of PD
VR
20
V
Operating Case Temperature
TC
−40 to +85
°C
Storage Temperature
Tstg
−40 to +85
°C
Assembly Temperature
Tasb
150 (15 Hr)
°C
Lead Soldering Temperature
Tsld
350 (3 sec.)
°C
Relative Humidity (noncondensing)
RH
85
%
RECOMMENDED OPERATING CONDITION
PARAMETER
Modulation Current
SYMBOL
Imod
CONDITIONS
TC = 25°C
MIN.
TYP.
25
MAX.
UNIT
mA
NX5307 SERIES
ELECTRO-OPTICAL CHARACTERISTICS
PARAMETER
SYMBOL
Operating Voltage
Vop
Threshold Current
Ith
(TC = -25°C, unless otherwise specified)
CONDITIONS
TYP.
MAX.
UNIT
1.1
1.5
V
10
15
mA
TC = 85°C
25
30
100
200
Po = 10 mW, TC = −40 to +85°C
Threshold Output Power
Pth
TC = −40 to +85°C, IF = Ith
Optical Output Power
Po
TC = −40 to +85°C, IF = Ith
Differential Efficiency
ηd
ηd (@85ºC)
Temperature Dependence of
Differential Efficiency
Δηd
Modulation Current
Imod
TC = 85°C
Center Wavelength
λC
Po = 10 mW, RMS (−20 dB)
TC = −40 to +85°C
Temperature Dependence of
MIN.
Δηd = 10 log
Δλ/ΔT
μW
8
10
mW
0.32
0.4
W/A
−3.0
−1.2
dB
ηd (@25ºC)
1 266
50
mA
1 360
nm
TC = −40 to +85°C
0.4
0.5
nm/
Center Wavelength
°C
Spectral Width
σ
Po = 10 mW, RMS (−20 dB)
TC = −40 to +85°C
1.0
2.5
nm
Rise Time
tr
10-90%
0.15
0.2
ns
Fall Time
tf
90-10%
0.15
0.2
ns
Monitor Current
Im
VR = 5 V, IF = Ith +25 mA
600
1 200
μA
Monitor Dark Current
ID
VR = 5 V
0.1
10
nA
500
nA
20
pF
1.0
dB
300
VR = 5 V, TC = −40 to +85°C
Monitor PD Terminal Capacitance
Ct
VR = 5 V, f = 1 MHz
6
Tracking Error*1
γ
Im = const. (@ Po = 10 mW, TC = 25°C)
−1.0
*1 Tracking Error: γ
Po
γ = 10 log
(mW)
TC = 25ºC
10
TC = -40 to +85ºC
Po
0
Im
(mA)
Im
Po
10
[dB]
NX5307 SERIES
TYPICAL CHARACTERISTICS (TC = −40 to +85°C, unless otherwise specified)
OPERATING CURRENT AND THRESHOLD
CURRENT vs. CASE TEMPERATURE
ºC
100
+8 5
Operating Current Iop (mA),
Threshold Current Ith (mA)
7.5
+25º
40ºC
TC = -
Optical Output Power Po (mW)
10
C
OPTICAL OUTPUT POWER
vs. FORWARD CURRENT
5.0
2.5
20
0
40
60
80
100
Center Wavelength λC (nm)
TEMPERATURE DEPENDENCE OF
CENTER WAVELENGTH
1340
1320
1300
1280
-40
-20
0
20
40
60
80
100
Case Temperature TC (ºC)
Remark
Iop
30
Ith
20
10
5
3
2
1
-60
-40
-20
0
20
40
60
Case Temperature TC (ºC)
Forward Current IF (mA)
-60
50
The graphs indicate nominal characteristics.
80
100
NX5307 SERIES
TYPICAL CHARACTERISTICS (TC = 25°C, unless otherwise specified)
OPTICAL OUTPUT POWER
vs. MONITOR CURRENT
FORWARD CURRENT vs.
FORWARD VOLTAGE
Optical Output Power Po (mW)
20
40
30
20
10
0
1
1800
1200
Monitor Current Im (µA)
SPECTRUM
TOLERANCE OF FIBER
COUPLING DISTANCE (Z)
1310
1320
Wavelength λ (nm)
Remark
600
Forward Voltage VF (V)
Relative Intensity
1300
10
0
2
Otical Output Power from Fiber Pf (mW)
Forward Current IF (mA)
50
2.0
Z
Pf
1.6
SMF
Po =
10 mW
1.2
0.8
0.4
0.0
5.8
6.0
6.2
6.4
6.6
6.8
Z-Axis Tolerance Z (mm)
The graphs indicate nominal characteristics.
Life Support Applications
These NEC products are not intended for use in life support devices, appliances, or systems where the malfunction of these products can reasonably
be expected to result in personal injury. The customers of CEL using or selling these products for use in such applications do so at their own risk and
agree to fully indemnify CEL for all damages resulting from such improper use or sale.
08/04/2004
A Business Partner of NEC Compound Semiconductor Devices, Ltd.
4590 Patrick Henry Drive
Santa Clara, CA 95054-1817
Telephone: (408) 919-2500
Facsimile: (408) 988-0279
Subject: Compliance with EU Directives
CEL certifies, to its knowledge, that semiconductor and laser products detailed below are compliant
with the requirements of European Union (EU) Directive 2002/95/EC Restriction on Use of Hazardous
Substances in electrical and electronic equipment (RoHS) and the requirements of EU Directive
2003/11/EC Restriction on Penta and Octa BDE.
CEL Pb-free products have the same base part number with a suffix added. The suffix –A indicates
that the device is Pb-free. The –AZ suffix is used to designate devices containing Pb which are
exempted from the requirement of RoHS directive (*). In all cases the devices have Pb-free terminals.
All devices with these suffixes meet the requirements of the RoHS directive.
This status is based on CEL’s understanding of the EU Directives and knowledge of the materials that
go into its products as of the date of disclosure of this information.
Restricted Substance
per RoHS
Concentration Limit per RoHS
(values are not yet fixed)
Concentration contained
in CEL devices
-A
Not Detected
Lead (Pb)
< 1000 PPM
Mercury
< 1000 PPM
Not Detected
Cadmium
< 100 PPM
Not Detected
Hexavalent Chromium
< 1000 PPM
Not Detected
PBB
< 1000 PPM
Not Detected
PBDE
< 1000 PPM
Not Detected
-AZ
(*)
If you should have any additional questions regarding our devices and compliance to environmental
standards, please do not hesitate to contact your local representative.
Important Information and Disclaimer: Information provided by CEL on its website or in other communications concerting the substance
content of its products represents knowledge and belief as of the date that it is provided. CEL bases its knowledge and belief on information
provided by third parties and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better
integrate information from third parties. CEL has taken and continues to take reasonable steps to provide representative and accurate
information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. CEL and CEL
suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for
release.
In no event shall CEL’s liability arising out of such information exceed the total purchase price of the CEL part(s) at issue sold by CEL to
customer on an annual basis.
See CEL Terms and Conditions for additional clarification of warranties and liability.